box meter vic enc only

Meter Enclosure, Series 230, Victorian Type

Catalogue Number: 230MV
box meter vic enc only
Colour:
Colour: Per UOM Std.
  • 1 PCE

Specifications

hide show
Range
Resi MAX
Product or component type
meter box
Enclosure/cubicle description
plain door enclosure
Device application
  • metering
  • distribution
    • Targeted country
      Victoria
      Enclosure mounting
    • semi flush
    • surface
      • Number of modules
        30
        Provided equipment
      • enclosure
      • fuse links
      • neutral link
      • removable meter panel
        • Protection device type
          miniature circuit breaker (MCB) - 63 A - 1P - 6 kA
          Cable entry
        • knock-out top and bottom
        • knock-out rear
          • Door type
            ventilated removable door with door retainer
            Door opening side
            right
            Lock type
            padlockable
            Material
            iron (galvanised)
            Protective treatment
            epoxy powder coat
            Width
            470 mm
            Height
            430 mm
            Depth
            280 mm
            IP degree of protection
            IP23
            Standards
            AS/NZS 3000
            EU RoHS Directive
            Compliant
            Circularity Profile
            N/A

            Frequently Asked Questions

            hide show

            What is the depth behind the panel on the 230MV?

            The depth behind the panel on the 230MV is 85mm.

            What is the dimension for behind internal panel in the 230MV?

            The dimension for behind internal panel in the 230MV is - 76mm

            For further information , visit link below:-
            https://www.clipsal.com/Trade/search-results?q=230MV
            User-added image

            What is the cut out for the 7500ATP?

            290mm X 290mm with a minimum ceiling cavity of 230mm

            What is the part number for a wall ex-fan 200mm with cut out of 230mm?

            The part number for a wall ex-fan 200mm with cut out of 230mm is - 7105A

            For further information , visit link below:-

            https://www.clipsal.com/Trade/search-results?q=7105A
            User-added image
             

            I am looking for a wall fan with a 240mm cutout and is physically approx 300mm square

            You can use a Clipsal 7106A or 7108A both have a 230mm cut out and are 271mm square

            Is there a replacement door for the 230MV?

            No there is no replacement door you will need to buy the full unit for replacement Part No.: 230MV
             

            Can 230MI series meter isolator enclosure be pad locked when the circuit breaker is in the ON and OFF position?

            230 series meter isolator is designed to be padlocked when the circuit breaker is in the OFF position for safety reasons. When the circuit breaker is in the ON position, 230MI cannot be padlocked. To prevent capability to lock when the circuit breaker is in the ON use only Clipsal Range MCB’s.

            For further information, please visit  https://www.clipsal.com/Trade/search-results?q=230MI


             

            Where can I get the wiring diagram for the control box (part number: 230CB) for 230MC Motor Case?

            Issue:
             Control box wiring diagram

            Product Line:
            Demo Box for Altivar Drives

            Environment:
             Demo box motor case part number 230MC

            Cause:
            None
             
            Resolution:
            Attached is the wiring diagram for the ATV drives Demo Case 230MC.
             

            What is the cut out size for 7105A, 200mm window exhaust fan?

            The cut out size for 7105A, 200mm window exhaust fan is 230mm diameter. 7105A is remotely switched with auto shutters,38W, IPX4, 600m³/hr.
            For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=7105A
            User-added image

            Is there a din rail, lockable enclosure with 4 modules?

            No, unfortunately this part is not available. However, there is the 230MI which is a lockable enclosure but it is only 3 modules.

            For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=230MI
             

            Is the 230LKV discontinued?

            Yes, unfortunately there is no replacement.

            Is there a wall fan with a pull cord to suit a 220mm cut-out?

            The closest we have is our 7108A which is a wall fan with pull cord and has a cut-out of 230mm.

            What is the dimensions of the 534P16S multi plate

            Dimensions 220mm x 220mm square

            What is the suffix for 230V for an LD4LD030

            The suffix would be 'U' for the 230V 

            Can you output 460V out of a drive with only 230V coming in and the drive is also rated for 230V?

            Issue:
            Can you output 460V out of a drive with only 230V coming in and the drive is also rated for 230V?

            Product Line:
            All drives

            Environment:
            All

            Cause:
            N/A

            Resolution:
            No.  A drive cannot act as a transformer.  In most cases what is coming in at the line side of a drive is what will be coming out.
             
            The only exception is the ATV12 drives that can accept 120V input and output 230V.  This is limited to 1 HP. 
             

            Is the 280MC still available

             No - not available in New Zealand

            Can Domae MCB's and RCCB's be used in a 400v residential switchboard?

            Yes. They are insulated to 440v.
            We only import and supply single pole MCB's specifically for the residential market. The 230v rated voltage marking complies with AS/NZS 60898-1 for use in 230v, 230/400v, or 400v systems as per section 5.3.1.

            What is the replacement/ alternate for mistral wall exhaust fan, part number 6108-0?

            7108A  and two 7100WP wall plates can be used as an alternate for 6108-0 mistral wall exhaust fan.
            7108A is Wall Mounted Exhaust Fan with pull cord switched shutters, 200MM Fan, 230mm diameter cut out, IPX4, 38W, 600m³/hr.
            For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=7108A

            User-added image

            7100WP is a wall plate to cover cutting errors for 7100 Series MaxAir fans (200mm) or to assist the replacement of older style Airflow or Mistral wall fans.
            For further information, please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=7100WP

            User-added image

            What is the replacement part number for wall exhaust fan 6110-0?

            7106A  with 2 wall plates 7100WP can be used as an alternate to the wall exhaust fan 6110-0.
            7106A is a 200mm wall mounted exhaust fan, switched remotely, auto shutters, BCA axial fan, IPX4, 38W, 230mm diameter cut out, 600m³/hr. For further information, please visit
            https://www.clipsal.com/Trade/Products/ProductDetail?catno=7106A
            User-added image

            7100WP is a wall plate to cover cutting errors for 7100 Series MaxAir fans (200mm) or to assist the replacement of older style Airflow or Mistral wall fans. For further information, please visit
            https://www.clipsal.com/Trade/Products/ProductDetail?catno=7100WP
            User-added image

            Looking for Power supplies 230V AC in 24V DC output with 2hour battery back up

             Nothing within our current range with these properties

            What is the part code for a 630A Contactor with 230V coil

             The part codes you need LC1F630 + LX1FL220 + LADN11

            What is the 230V Coil for the Everlink Contactor LC1DT60A ?

            240V coil =  LXD3U7

            Is the 230CS board still available?

             No, unfortunately the 230CS is no longer available.

            For further information please visit https://www.clipsal.com/Trade

            What are the useable dimensions of the DBFPMK panel meter kit?

            Height= 260mm if cut to allow use of extra din rail in DBF45 or DBF60, panel is 290mm uncut
            Width= 325mm
            Depth= 70mm
            Instructions attached
             

            Dimension for PDL 663VH

            Plate 130mm x 32mm

            What are the cut out dimensions for the 7500ATP-WE

            The cut out dimensions for the 7500ATP-WE are 290mm x 290mm

            What is the alternative for the 250ml clear glue 240A?

            There is no direct alternative to the clear 250ml jointing cement in the squeeze bottle.

            We only offer our range of four sizes with a brush incorporated in the lid.    

            For further information please visit https://www.clipsal.com/Trade/search-results?q=jointing%20cement.

            Is there a window fan available 280mm?

            There is no 280mm fan available.

            What is the part code for a 320A 3P Contactor 230V interlock aux 2 n/o 2n/c

            The part codes are LC1F330 coil + LX1FH2402 interlock  + LA9FJ970 aux  = LADN22

            What are the specifications for a PDL 573 pull cord ceiling switch ?

            Plate size:  66mm diameter
            Mounting Centres: 50mm
            Rated at 230V - 240V a.c.  16A resistive, 16A inductive   8AX fluorescent
             

            What is the product code for the iEM2000 Acti9 230V 40A din rail mount energy monitor?

            The product code is A9MEM2000. Please see the attached datasheet for more information.
             

            what is the Acti 9 code for Merlin Gerin 15515?

            A9C30831 is the Acti9 code for the 1P 1NO 32A 230v AC impulse relay.

            What is the part number for the 22mm 230v Green Pilot light in Metal?

            The part number for the complete 22mm 230v AC Green Pilot light in Metal is "XB4BVM3"
            If a different voltage is required the M3 in the code can be changed to B3 for 24v AC/DC, or G3 for 110v AC

             

            What are the dimensions of the earth / neutral bar GE6324 ?

            GE6324 Earth / neutral Bar Length = 300 MM
            Width = 30MM + 15MM + 15MM (30MM is where the bars sit - then the metal bracket bends on an angle twice)
            The Bars are 220mm long - Earth bar is flat on the Bracket  - Neutral bar is on the standoffs - MEN link is cable tied as in the photos attached

            What is the part number for a 250mm ex-fan with auto retract blades?

            The part number for a 250mm ex-fan with auto retract blades is - 6220-0

            For further information , visit link below:-
            https://www.clipsal.com/Trade/search-results?q=6220-0
            User-added image

            Is there an Altivar drive available that can convert 220V single phase input to 460V three phase output?

            Issue:
            Is there an Altivar drive available that can convert 220V single phase input to 460V three phase output?

            Product Line:
            All Altivar Variable Frequency Drives and Altistart Soft Starters.

            Environment:
            All models, All serial numbers.

            Cause:
            Customer has 460V three phase motors available but only 220V single phase power available.

            Resolution:
            No, there are no drive products that can convert 220V single phase power to 460V three phase power. There are drives in our product lineup that can convert single phase 230V to three phase 230V. If the motor is dual rated for 208-230V / 460V operation, then wiring it for 230V may be a better option.
             

            What is the part number for a moduline 130mm drop in lid?

            The part number is PL125CL*

             

            Only 125mm not 130mm and drop in was discontinued only have a S clip on lid now

            Is it possible to run an 480V Altivar drive with 480V supply but their motor is only rated for 230V?

            Issue: 
            Is it possible to run an 480V Altivar drive with 480V supply but their motor is only rated for 230V?

            Product Line:
            All 480 Volt Altivar drives.

            Environment:
            All models rated for 480V input and output, All serial numbers.

            Cause: 
            Incompatible motor/drive selection made

            Resolution:
            It is not recommended to operate a 208/230V motor from a 480V drive.   It is possible if certain conditions are met to do so temporarily however it is strongly advised that the correct voltage drive/motor be installed.  

            A 230V motor requires roughly twice as much current as a 460V motor to produce the same amount of horsepower and this can exceed the rating of the 480V drive.   Also, you must set the rated motor voltage in the drive to match the actual rated voltage of the motor.  Refer to the programming manual for your particular drive for instructions to change this parameter.  Also, be aware that the output of the drive is not a true sine wave.  It is a pulse width modulated signal generated by the IGBTs and each of these pulses will be at the voltage of the DC bus.  On a 230V drive the DC bus voltage is typically around 325 VDC.  On a 480V drive this voltage is typically around 680VDC.  This increased voltage may cause damage to your motor.  If a 480V drive must be used on a 230V motor temporarily, a 5% load reactor should be placed between the output of the drive and the motor to help reduce this voltage.  In all cases it is advised to replace the motor or drive as needed to a selection that is compatible.   Note that a 480V drive can not operate with 230V input so if 480V supply is all that is available then the drive must be rated for 480V.  In this situation it would be best to replace the motor with one rated for 460V.

             

            Is the ATV12 series available in panel mount configuration for voltage code F1?

            Issue:
            Is the ATV12 series available in Panel mount configuration for voltage code F1?
             
            Product Line:

            ATV12 series drives
             
            Environment:

            All ATV12 drives with F1 voltage code (120V single phase input, 230V three phase output)
             
            Cause:
            Information not available in current literature
             
            Resolution:
            The ATV12P***** series drives are not available with voltage code F1 for single phase 120VAC INPUT and 230V 3 phase Output.

            Why does the 2012 ATV312 Annex show circuit breakers for the single-phase 230v drives and the 2014 Annex does not show them?

            Issue:
            Why does the 2012 ATV312 Annex show circuit breakers for the single-phase 230v drives and the 2014 Annex does not show them?

            Product Line:
            ATV312 drives 

            Environment:
            230vac single-phase

            Cause:
            Why does the 2012 ATV312 Annex show circuit breakers for the single-phase 230v drives and the 2014 Annex does not show them?

            Resolution
            It was dropped by accident. It will be added again in the next ATV312 Annex update.

            What is part number for 200mm pull cord wall fan?

            The part number for 200mm pull cord wall fan is 7108A.

            What is part number for 200mm window fan?

            No unfortunately there is no 200mm window fan available.

            What are the outside dimensions of the 7100WP?

            The dimensions are as follows: 330MM x 330MM.

            What are the dimensions for the MB248D32?

            The dimensions for the MB248D32 are 1000mm (H) x 580mm (W) x 235mm (D).

            What are the 9013FHG pressure switch contacts rated at?

            Issue:
            Contact Rating of 9013F Pressure Switches

            Product Line: 
            Pressure, vacuum and Float Switches 

            Environment:
            9013 Type F Pressure Switch 

            Resolution:
            Those contacts have a control circuit rating of A600.
            They are DC rated at 1/4 HP at 115V and 230V (Except form M4)
            They are Single Phase AC rated 1 1/2 HP at 115V, 2 HP at 230V
            They are Polyphase rated 2 HP at 115V, 3 HP at 230V, and 1 HP at 460/575V.

            This also applies to the 9013 FHG2, 9, 12, 13, 44, 49 9013 FSG, and FSW.

            What is the replacement 230V contactor/ coil for LC1D4011?

            The LC1D4011 contactor/ coil was replaced with LC1D40AU7.

            For futher informaion please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=LC1D40AU7

            https://www.elektro4000.de/images/product_images/popup_images/Schneider-Electric-Leistungsschuetz-LC1D40AU7-388576_0.jpg

            What is the part series for Digital Watt Hour Meter ?

            This is a part of the Acti9 Series
            A9M17065 - 230V 63A Din Mounted Digital Watt Hour Meter.
            For more information - see Trade Product Guide - Page 270
             

            Can the A9F44210 be used with 110v AC?

            Yes it can, the only difference between a 100v and 230v is that you will get 36kA breaking capacity as opposed to 20kA (230v).



             

            Is the extra switch in the 15X removable?

            Yes, the extra switch in the 15X is removable. Any 230v rated 30 series mec will fit in it's place.

             

            Can I use a 230v Smart-UPS in a 277v environment?

            Issue:

            Use of Smart-UPS products in 277v environments

            Product Line:

            Smart-UPS

            Environment:

            All Line Interactive 230v models, All Serial Numbers

            Cause:

            Product Information

            Resolution:

            Line Interactive Smart-UPS (SU, SUA, SMT, SMX) products with an "I" in the suffix of the part number are designed for a nominal 230v input. (Ex: SMT1500I, SUA3000XLI, etc). Some units can also be configured for optional nominal input voltages of 220v and 240v. Although transfer points can be widened to allow the unit to function online with even higher input voltages, the unit is not designed for this and will ultimately run into issues.

            Problems in this type of configuration include:

            • Short runtime due to repeatedly switching to battery operation
            • Unintentional load drops due to discharged batteries
            • Shortened battery life due to frequent discharges
            • UPS Not turning back on after a power outage due to high input voltage
            • Increased wear and tear on the UPS hardware by continuous mode switching

            Using a 230v "I" unit in a 277v environment is not supported or recommended.

            The web page for each product will list a nominal input voltage, and if any other input voltages are acceptable they will be listed as "Other Input Voltages".  We do not currently offer a Smart-UPS product for use in 277v environments.

            The specification for "Input voltage adjustable range for mains operation" on our product pages is the full range of operation. This includes the use of Boost and Trim with the UPS voltage transfer points configured to their widest setting. This full range may be encountered on occasion during power events and is not meant to indicate normal online operation of the UPS. Smart-UPS products are designed for use in environments supported by their Nominal Input Voltage or any listed "Other Input Voltages" only.

             

            Show More