socket o'let telephone surr

Socket Outlet Telephone SurRound

Catalogue Number: 2031VTO
socket o'let telephone surr
Colour: White Electric
Colour: Per UOM Std.
  • White Electric 1 PCE
Added to cart

Specifications

hide show
Range of product
Medilec 2000 Series
Product brand
Clipsal
Quantity per set
set of 1
Cover type
full cover plate
Marking
without marking
Local signalling
without light indicator
Standards
  • AS/NZS 3112
  • AS 3100
  • AS 3109
  • AS/NZS 3122:approval number S/1
    • EU RoHS Directive
      Compliant
      Circularity Profile
      N/A

      Documents & downloads

      hide show
      Filter items
      • All

      • Product Brochures

      • CAD Files and Packs

      • Technical Data Catalogues

      • Installation Instruction

      • Product Environmental

      • Operating Manuals

      • Specifications

      • Certificates (MSDS)

      Frequently Asked Questions

      hide show

      Do you make a 2031VHA like the 2032VHA?

      Unfortunately, we only make a 2 gang version.

      What is the part number for 610 Telephone socket and mounting plate , with Brushed Aluminium cover?

      The part number for 610 Telephone socket and mounting plate , with Brushed Aluminium cover is - C2031VTO & C2031VTOC & 3110SK610
      For further information , visit links below:-
      https://www.clipsal.com/Trade/search-results?q=C2031VTO
      https://www.clipsal.com/Trade/search-results?q=C2031VTOC
      https://www.clipsal.com/Trade/search-results?q=3110SK610
      User-added image

      What is the white cover plate for a 2031VCS

      The part code is 2000-WE surround cover plate

      Does the 2031V66 come in architrave?

      No it doesnt

      Can the mech from 2031VETF be bought seperately ?

      No, the mech is intergrated into the grid, and cannot be purchased seperately.

      Do you do a 2031VH in red?

      Yes the part number is 2031VH-RD

      Can part number 30M35 be used in 2031V66?

      No. Unfortunately, part number 30M35 CANNOT be used in 2031V66.

       

      Can the 2031VETR and 2031VETR3 operate without a neutral?

      The 2031VETR3 will not operate without a neutral however the 2031VETR WILL operate without a neutral as it was designed purely as a 2 wire device I.e. Active & Switched Active.

      Is the 2031vetr available in the C2000 series?

      It is only available in either the standard series ( 31VETR) or 2000 series ( 2031VETR)

      Is mech only available for part number 2031VETR?

      No the mech comes only complete in plate.

      What is the time delay available on the 31VETF or 2031VETF?

      The 31VETF Series is adjustable to allow fans to continue to run from 3 minutes to 10 minutes (approximately) after the lighting is turned off. The delay adjustment is accessible on the
      rear of the device.

      Can the 2031VETR switch 24V DC?

      No, it is only for 240V~.

      For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=2031VETR

      Do you do the 2031V66 with double pole switches?

      No, the 2031V66 does not have double pole mechanisms.

      Some of the key features are:
      • Switches have been re-designed to provide mechanisms that can be re-orientated horizontally or vertically
      • 1 gang weatherproof switch

      For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=2031V66

      Can the 2031VETR be two wayed?

      Yes the 2031VETR can have a remote switch wired to it.

      For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=2031VETR

      Does the 2031VETR switch an exhaust fan?

      Yes the 2031VETR will switch small motor loads. (maximum 2A)

      For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=2031VETR


       

      Does the 2031VETR have dip switches?

      Yes, the 2031VETR does have dip switches.

      For more information, please refer to the link:
      https://www.clipsal.com/Trade/Products/ProductDetail?catno=2031VETR

      Can you get a clipsal plate 2031VH with a 30HM-WE pre assembled?

      No, unfortunately you will need to buy the parts separately.

      Can the grid for the 2031v66 be purchased without mechs?

      No, We do not supply or encourage this as the 2031v66 has a specific gasket set up to ensure weatherproof rating and this may be compromised if tampered with therefore we only sell them assembled.

      What is the mech that fits in the 2031V66 switch?

      Unfortunately we dont do the mech as a spare part it is essentually a 30 mech with a rubber seal between the contacts ant the dolly and we dont do that mech as a spare part.

      What is the minimum load for a 2031VETR?

      The minimum load for a 2031VETR is 20mA.

      For more information, please refer to the link:
      https://updates.clipsal.com/ClipsalOnline/Files/Brochures/W0001508.pdf 

      What is the part number for cover to suit P2031VA?

      The part number for cover to suit P2031VA is - P2001

      ​Is there an alternative C-Bus Switch for 5031NL-WE?

      Yes, one off 2031VH + one off 5031NMML

      What is mounting block to suit P2031VH?

      Part no P2031VH will fit on either 449A or 449ASD mounting block

      Is there a Permanent connection unit in the Medilec range?

      No Medilec permanent connection unit
      Use 2031VH with a 38TB Mech.

      Is there a part similar to the grid plate 2031VX that has a terminal block on the back?

      Yes, The grid plate has a terminal block on the back and is rated at 30A. The part number is 2031VXCB.

      What is the timing range for a 2031VETR-WE?

      The timing range for a 2031VETR-WE is 15 seconds to 254 minutes.
      Please see following link for complete range
      https://www.clipsal.com/Trade/Products/ProductDetail?catno=2031VETR3

      How does 2031VETF run on timer switch operate?

      The Clipsal 2031VETF Series is an electronic time delay switch which provides extended exhaust fan operations to ensure proper ventilation in bathrooms and toilets. It uses a single switch to operate both lighting and an exhaust fan. Both loads switch on simultaneously when the switch is operated, but when the lighting is turned off, the exhaust fan continues to run for several minutes.
      Time Delay Intervals Available:
      The 201VETF Series is adjustable to allow fans to continue to run from 3 minutes to 10 minutes (approximately) after the lighting is turned off. The delay adjustment is accessible on the rear of the device.
      Operation:
      Turning on the switch will cause both the lights and the fan to operate. The electronic timer starts when the switch is turned off. The lights are controlled directly by the switch, however, the fan will run for its preset timer period when the lights are turned off. Turning the lights on and off again, while the fan is still running, will cause the timer period to restart.
      The fan will activate for a timer cycle whenever power is re-applied to the unit. eg. initial installation, power failure/return, fan replacement.
      for further information. please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=2031VETF
      User-added image

       

      is there a push button timer which i can place in a switch plate with other switches

      We do not do a timer which is removable, the closest is a 2031VETR3-WE.
      This comes on it's own plate which it cannot be removed from.
      This timer allows the operator to push the button and will remain on until the time has lapsed.
      please see below link for more information.
      https://www.clipsal.com/Trade/search-results?q=2031vetr

      Is there a timer switch in Saturn Series available?

      No, however you can use the timer 2031VETR  as a remote timer ie place it in the ceiling and have cables running to a Saturn Series plate with a bell press. When the bell press is pressed it will trigger the 2031VETR.

      Bell press part number is a 60PBBP

      The saturn series plate less mechanism is 4061VH.

      What is the part number for the key only for the 2036VKT4?

      The part number for the key only for the 2036VKT4 is 2036VKT.

      Some of the key features are:
      • To suit 2036VKT and 36VKT series switches
      For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=2036VKT
       

      Is the 2031V66 switch 2 way compatible?

      Yes, as it is based on 30 series mech with 4 terminals it is 2 way compatible.

      Some of the key features are:
      • 1 gang weatherproof switch
      • Standard size gridplate and surround complete with one 30M switch
      • Vertical mount
      • 116 mm Length x 76 mm Width x 30 mm Depth
      • 84 mm apart Mounting centres

      For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=2031V66

      What is the Brushed Aluminum cover plate for the C2031VH

       Part code C2031C-BA

      What is the Cver Plate for C2031VT2W

      The cover plate is C2031VT2WC-BA - FAQ Already exists

      What is the Brushed Aluminum cover plate to suit C2031VT2W

       Part Code is C2031VT2WC-BA

      What is the part number for an OFF delay timer for a 20amp strip heater?

      There is no OFF delay timer that has 20amp rating .
      You can use run on timer  , 2031VETR , controlling 20amp contactor with 240VAC coil - LC1D09U7 for 20amp resistive load
      For further information , visit link below:-
      https://www.clipsal.com/Trade/search-results?q=2031VETR
      https://www.schneider-electric.com.au/en/search/LC1D09U7
      User-added image

      What IP66 rating weather proof indoor switches are there avaliable?

      The IP66 rated weather proof indoor switches avaliable are 2031V66, C2031V66.

      What is the part number for a prestige single gang switch?

      The part number is P2031VA.

      Do you do a C2031V66 in a 3 gang?

      No unfortunately we only go up to 2 gang (C2032V66)

      What are the part numbers for a single / double prestige grid and plates and mechs

      Part numbers are P2031VH (single) P2032VH (double) P30M (Mech)

      Is gasket only available for part number 2031V66?

      The gasket is not available for this part

      for more information on this part please refer to https://www.clipsal.com/Trade/Products/ProductDetail?catno=2031V66

      User-added image

      What coil codes are available for the U-Line motor starter Control Units?

      The coil codes available for the U-Line Motor Starter control units are as follows:
      24VDC is BL
      24VAC is B
      48-72V DC or 48V AC is ES
      110-240V AC/DC is FU.
      We do not have 480VAC coils available


      CTA-ID : 2031577

      Can part number 2031VETR3 be used in conjunction with air conditioner?

      2031VETR3 can be used with air ocnditioner up to 10amps.

       

      Do you do a 2031VETR3 in Classic Series?

      No unfortunately we don't do a 2031VETR3 in Classic Series. However, this unit can be remotely operated. Therefore you can place the 2031VETR3 In the wall cavity and can be triggered by a C2031VH plate with a 30PBBP switch mechanism. This insures the correct look while obtaining correct functionality.


       

      Can I change the output state of the 2031VETR?

      No, the output of the 2031VETR is N/O and can not be changed.

      However the 2031VETR3 has the option to choose between N/O and N/C.

      For further information please visit https://www.clipsal.com/Trade



       

      Will the LA4DC1U work with the new CAD32BD relay?

      Issue:
      Will the LA4DC1U work on the CAd32BD relay

      Product Line:
      IEC relays and accessories

      Environment:
      Products sold and used in the United States

      Cause:
      Identifying product compatibility

      Resolution:
      The CAD32BD with DC coil has built-in coil suppression protection as standard so the LA4DC1U is not needed.


      CTA-ID : 2031917

      ​Is there an alternative C-Bus Switch for C5031NL-WE?

      The following parts are required to build the equivelent: 1x C2031VH + 1x 5031NMML

      Are mechs only available for part number C2031V66?

      No. Unfortunately, Mechs only are not available for switch.

      2031VETR3 - is it an intermediate switch? Can it be used in a stairwell to control a load from three floors?

      2031VETR3 is three wire switch. 
      Additional switches, 30mbp or the 30pbbp, can be installed in parallel to activate the timer from more than one location.

      Please go to the website via the following link www.clipsal.com/Trade/Products/ProductDetail and check under the Documentation Tab for more information.
       

      Is the 2031VETR3 available in a 15 amp version?

      No , The 31VETR series are available in 10a versions only
      For more information regarding this product range please visit the Clipsal web site on the link provided.
      https://www.clipsal.com/Trade/search-results?q=31vetr
      User-added image

      What is the mounting height of a PowerPact H Frame 3-pole breaker

      Product Line:
      Circuit Breakers
      PowerPact H
      I Line

      Environment:
      Electrical Distribution Equipment

      Resolution:
      It takes 4.5`` of mounting height.
       