Specifications

hide show
Product brand
Clipsal
EU RoHS Directive
Compliant
Circularity Profile
N/A

Documents & downloads

hide show
Filter items
  • All

  • Product Brochures

  • CAD Files and Packs

  • Technical Data Catalogues

  • Installation Instruction

  • Product Environmental

  • Operating Manuals

  • Specifications

  • Certificates (MSDS)

Frequently Asked Questions

hide show

Is the 2031vetr available in the C2000 series?

It is only available in either the standard series ( 31VETR) or 2000 series ( 2031VETR)

Can the 2031VETR and 2031VETR3 operate without a neutral?

The 2031VETR3 will not operate without a neutral however the 2031VETR WILL operate without a neutral as it was designed purely as a 2 wire device I.e. Active & Switched Active.

Is mech only available for part number 2031VETR?

No the mech comes only complete in plate.

What is the minimum load for a 2031VETR?

The minimum load for a 2031VETR is 20mA.

For more information, please refer to the link:
https://updates.clipsal.com/ClipsalOnline/Files/Brochures/W0001508.pdf 

Can the 2031VETR switch 24V DC?

No, it is only for 240V~.

For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=2031VETR

Can the 2031VETR be two wayed?

Yes the 2031VETR can have a remote switch wired to it.

For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=2031VETR

Does the 2031VETR switch an exhaust fan?

Yes the 2031VETR will switch small motor loads. (maximum 2A)

For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=2031VETR


 

Does the 2031VETR have dip switches?

Yes, the 2031VETR does have dip switches.

For more information, please refer to the link:
https://www.clipsal.com/Trade/Products/ProductDetail?catno=2031VETR

Can the mech from 2031VETF be bought seperately ?

No, the mech is intergrated into the grid, and cannot be purchased seperately.

What is the time delay available on the 31VETF or 2031VETF?

The 31VETF Series is adjustable to allow fans to continue to run from 3 minutes to 10 minutes (approximately) after the lighting is turned off. The delay adjustment is accessible on the
rear of the device.

Is the 2031VETR3 available in a 15 amp version?

No , The 31VETR series are available in 10a versions only
For more information regarding this product range please visit the Clipsal web site on the link provided.
https://www.clipsal.com/Trade/search-results?q=31vetr
User-added image

What is the timing range for a 2031VETR-WE?

The timing range for a 2031VETR-WE is 15 seconds to 254 minutes.
Please see following link for complete range
https://www.clipsal.com/Trade/Products/ProductDetail?catno=2031VETR3

Can part number 2031VETR3 be used in conjunction with air conditioner?

2031VETR3 can be used with air ocnditioner up to 10amps.

 

Can I change the output state of the 2031VETR?

No, the output of the 2031VETR is N/O and can not be changed.

However the 2031VETR3 has the option to choose between N/O and N/C.

For further information please visit https://www.clipsal.com/Trade



 

2031VETR3 - is it an intermediate switch? Can it be used in a stairwell to control a load from three floors?

2031VETR3 is three wire switch. 
Additional switches, 30mbp or the 30pbbp, can be installed in parallel to activate the timer from more than one location.

Please go to the website via the following link www.clipsal.com/Trade/Products/ProductDetail and check under the Documentation Tab for more information.
 

Does 2031VETR3 have a remote input?

Yes you can remotely switch the timer using a bell press mechanism.
Please follow link below for more information.
https://www.clipsal.com/Trade/Products/ProductDetail?catno=2031VETR3

What type of switch mechanisms can be used to remotely switch 31VETR3 / 2031VETR3 push button timer?

Momentary switch mechanisms (Bell press mechanisms) can be used to remotely switch 31VETR3 / 2031VETR3. Example of 30 series momentary switch mechanisms are 30PBBP or 30PBBPL.
For further information, please visit 
https://updates.clipsal.com/ClipsalOnline/Files/Brochures/W0001273.pdf
https://www.clipsal.com/Trade/Products/ProductDetail?catno=30PBBP
https://www.clipsal.com/Trade/Products/ProductDetail?catno=30PBBPL

is there a push button timer which i can place in a switch plate with other switches

We do not do a timer which is removable, the closest is a 2031VETR3-WE.
This comes on it's own plate which it cannot be removed from.
This timer allows the operator to push the button and will remain on until the time has lapsed.
please see below link for more information.
https://www.clipsal.com/Trade/search-results?q=2031vetr

Is there a timer switch in Saturn Series available?

No, however you can use the timer 2031VETR  as a remote timer ie place it in the ceiling and have cables running to a Saturn Series plate with a bell press. When the bell press is pressed it will trigger the 2031VETR.

Bell press part number is a 60PBBP

The saturn series plate less mechanism is 4061VH.

How can 31VETR3/ 2031VETR3 push button timers be remotely switched?


For 31VETR3/ 2031VETR3 push button timers to be remotely switched, additional switches have to be installed in parallel, allowing the timer to be activated from one or more remote locations as shown in the wiring diagram below:


NOTE:
• The remote switch wiring must be rated for 240V a.c.
• The sum of cable lengths used to connect the remote switches must not exceed 100m.
• Remote switches MUST be Normally Open momentary operation type switches.
 

How does the three wire push button timer 31VETR3 or 2031VETR3 work?

The built in push button on the 31VETR3 or 2031VETR3 has the following functions:
• Pressing the button when the timer is passive will initiate timing and set the load, and indicator, to the active state according to the configuration switch settings.
• Pressing the button during timing will cancel timing and set the load, and indicator, to the passive state according to the configuration switch settings.
• To restart the timer when the load is already on, simply perform consecutive turn-on and turn-off functions.
For further information, please refer to the below link:
https://www.clipsal.com/Trade/Products/ProductDetail?catno=31VETR3
https://www.clipsal.com/Trade/Products/ProductDetail?catno=2031VETR3
 

Will the 2031VETR3 handle an Air Conditioner?

The unit has a powerful 10AX switching capability. However, regarding the Air Conditioner, it comes under a "Motor Load" which then de-rates it to 2 Amp's.
Generally speaking, a small AC is 11 Amp's and up! Therefore it is inadequate and the use of a contactor in conjunction with the 2031VETR3 is needed.

For further specifications on this product please visit https://updates.clipsal.com/clipsalonline/files/brochures/w0001156.pdf
 
 

Do you have a two wire time delay switch available?

Yes, we do have a two wire time delay switch available. The part number is 31VETR.

What is the part number for an OFF delay timer for a 20amp strip heater?

There is no OFF delay timer that has 20amp rating .
You can use run on timer  , 2031VETR , controlling 20amp contactor with 240VAC coil - LC1D09U7 for 20amp resistive load
For further information , visit link below:-
https://www.clipsal.com/Trade/search-results?q=2031VETR
https://www.schneider-electric.com.au/en/search/LC1D09U7
User-added image

Is there a Saturn push button timer plate?

No there is not, however using a 2031VETR3 with a 60PBBP to remotely switch it from a saturn plate will achieve the same result.

Do you do a 2031VETR3 in Classic Series?

No unfortunately we don't do a 2031VETR3 in Classic Series. However, this unit can be remotely operated. Therefore you can place the 2031VETR3 In the wall cavity and can be triggered by a C2031VH plate with a 30PBBP switch mechanism. This insures the correct look while obtaining correct functionality.


 

How does 2031VETF run on timer switch operate?

The Clipsal 2031VETF Series is an electronic time delay switch which provides extended exhaust fan operations to ensure proper ventilation in bathrooms and toilets. It uses a single switch to operate both lighting and an exhaust fan. Both loads switch on simultaneously when the switch is operated, but when the lighting is turned off, the exhaust fan continues to run for several minutes.
Time Delay Intervals Available:
The 201VETF Series is adjustable to allow fans to continue to run from 3 minutes to 10 minutes (approximately) after the lighting is turned off. The delay adjustment is accessible on the rear of the device.
Operation:
Turning on the switch will cause both the lights and the fan to operate. The electronic timer starts when the switch is turned off. The lights are controlled directly by the switch, however, the fan will run for its preset timer period when the lights are turned off. Turning the lights on and off again, while the fan is still running, will cause the timer period to restart.
The fan will activate for a timer cycle whenever power is re-applied to the unit. eg. initial installation, power failure/return, fan replacement.
for further information. please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=2031VETF
User-added image

 

Can the timer 2031VETR3 run a 1500W timer?

The 2031VETR3 timer can run 1500W heater as it is rated to 10A and 1500W is = 6.52A. There fore it is well with in its rating

                                       Watts (P)                                                 1500

Current (A) =          ----------------------                     =        ----------------------        = 6.52A
                                    Voltage  (V)                                                230

Can part number 30M35 be used in 2031V66?

No. Unfortunately, part number 30M35 CANNOT be used in 2031V66.

 

I have 2 wire 31VETR and i dont have enough load will a 31CAP do the trick?

It will improve the situation however we cannot confirm wether it will fix the problem or not. The alternative is to use the three wire design 31VETR3

Can a run on timer be operated remotely by bell press mech?

Yes, the 2031VETR-WE can be operated by a 30PBBPL-WE

What IP66 rating weather proof indoor switches are there avaliable?

The IP66 rated weather proof indoor switches avaliable are 2031V66, C2031V66.

Do you do a 2031VH in red?

Yes the part number is 2031VH-RD

What is the part number for the key only for the 2036VKT4?

The part number for the key only for the 2036VKT4 is 2036VKT.

Some of the key features are:
  • To suit 2036VKT and 36VKT series switches
For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=2036VKT
 

Do you have a weatherproof push button timer that does 2 hours?

No, not as a single part, but you can make one with a 56PB push button and a 31VETR timer.

Can the 31VETR , be used with 2 way switching ?

Yes , with the use of a bell press switch mech switching neutral to unit - 31VETR
emailed customer installation instructions...
For further information , visit link below:-
https://www.clipsal.com/Trade/search-results?q=31VETR
User-added image

Is gasket only available for part number 2031V66?

The gasket is not available for this part

for more information on this part please refer to https://www.clipsal.com/Trade/Products/ProductDetail?catno=2031V66

User-added image

What colours are the PDL 680M32 available in?

The PDL 680M32 (switch module, 1 way, 2 terminal, 32A, 240V) is only available in white or black.
https://www.pdl.co.nz/product-details.aspx?rcat=products&catid=0&id=825

Can i wire multiple 30PBBP momentary press mechanisms in parallel with the 2031VETR3 time delay switch?

It is a momentary press so there isn't any restriction in how many mechanisms are wired in parallel providing your cable length doesn't exceed 100M.


Some of the key features are:
  • 0 - 15 Hours timer range
  • Surface mounted
  • 84 mm mounting centre
  • N.O/N.C contact type
  • -10 to 50 deg C
  • Improved terminal design-Ease of wiring termination and simplified installation
  • Connection for remote push-button switch-Permits remote control of timer from any number of locations using a standard push-button switch.
  • Variable timer settings-Allows the timer to be used for maximum energy savings in a wide range of applications
  • New enclosure design-Provides more room for wiring and easier fitting into standard wall box
  • State of the art microprocessor design-Highly reliable and accurate timing
  • Near zero crossing turn on switching-Prolongs the life of the relay contacts - in excess of 100,000 operations
  • Simple set up procedures-Fast installation
For further information please visit www.clipsal.com/Trade/Products/ProductDetail?catno=2031VETR3


 

Do you make a 2031VHA like the 2032VHA?

Unfortunately, we only make a 2 gang version.

What is the white cover plate for a 2031VCS

The part code is 2000-WE surround cover plate

What is the part number for 2000 series run on timer unit?

The part number for 2000 series run on timer unit is - 2031VETR

For further information , visit link below:-
https://www.clipsal.com/Trade/search-results?q=2031VETR
User-added image

What is the part number for a run on timer?

The part number for a run on timer is - 2031VETR
For further information , visit link below:-
https://www.clipsal.com/Trade/search-results?q=2031VETR
User-added image

Does the 2031V66 come in architrave?

No it doesnt

Can part number 31VETR3 run a 1.6kw inductive load?

Yes, they will operate up to 2.4kw inductive load. 

What is the part number for 610 Telephone socket and mounting plate , with Brushed Aluminium cover?

The part number for 610 Telephone socket and mounting plate , with Brushed Aluminium cover is - C2031VTO & C2031VTOC & 3110SK610
For further information , visit links below:-
https://www.clipsal.com/Trade/search-results?q=C2031VTO
https://www.clipsal.com/Trade/search-results?q=C2031VTOC
https://www.clipsal.com/Trade/search-results?q=3110SK610
User-added image

Do you do the 2031V66 with double pole switches?

No, the 2031V66 does not have double pole mechanisms.

Some of the key features are:
  • Switches have been re-designed to provide mechanisms that can be re-orientated horizontally or vertically
  • 1 gang weatherproof switch

For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=2031V66

Can the 31VETR3 be used as normally open and normally closed contact?

Yes, the 31VETR3 can be used as normally open and normally closed contact.

For more information, please refer to the link:
https://updates.clipsal.com/ClipsalOnline/Files/Brochures/W0001273.pdf 

Image result for 31VETR3 Clipsal

Can the grid for the 2031v66 be purchased without mechs?

No, We do not supply or encourage this as the 2031v66 has a specific gasket set up to ensure weatherproof rating and this may be compromised if tampered with therefore we only sell them assembled.

What is the mech that fits in the 2031V66 switch?

Unfortunately we dont do the mech as a spare part it is essentually a 30 mech with a rubber seal between the contacts ant the dolly and we dont do that mech as a spare part.
Show More