label - 2031VETF-WE
Image of 2031VETF timer 1g light cont delay fan
label - 2031VETF-WE
Image of 2031VETF timer 1g light cont delay fan

Time Delay Switch, 1 Gang, 10 A

Catalogue Number: 2031VETF
label - 2031VETF-WE
Image of 2031VETF timer 1g light cont delay fan
label - 2031VETF-WE
Image of 2031VETF timer 1g light cont delay fan
Retail
$504.80
RRP (Inc. GST)
Colour White Electric (WE)
  • White Electric 1 PCE

Specifications

hide show
Product brand
Clipsal
Range of product
Series 2000
Device presentation
basic element with full cover plate
[Ue] rated operational voltage
220...240 V
Package 1 Weight
212 g
Package 1 Height
71 mm
Package 1 width
90 mm
Package 1 Length
118 mm
EU RoHS Directive
Pro-active compliance (Product out of EU RoHS legal scope)

Documents & downloads

hide show
Filter items
  • All

  • Product Brochures

  • CAD Files and Packs

  • Installation Instruction

  • Certificates (MSDS)

Frequently Asked Questions

hide show

What is the time delay available on the 31VETF or 2031VETF?

The 31VETF Series is adjustable to allow fans to continue to run from 3 minutes to 10 minutes (approximately) after the lighting is turned off. The delay adjustment is accessible on the
rear of the device.

Can the mech from 2031VETF be bought seperately ?

No, the mech is intergrated into the grid, and cannot be purchased seperately.

Can the 2031VETR and 2031VETR3 operate without a neutral?

The 2031VETR3 will not operate without a neutral however the 2031VETR WILL operate without a neutral as it was designed purely as a 2 wire device I.e. Active & Switched Active.

Is the 2031vetr available in the C2000 series?

It is only available in either the standard series ( 31VETR) or 2000 series ( 2031VETR)

Is mech only available for part number 2031VETR?

No the mech comes only complete in plate.

What is the minimum load for a 2031VETR?

The minimum load for a 2031VETR is 20mA.

For more information, please refer to the link:
https://updates.clipsal.com/ClipsalOnline/Files/Brochures/W0001508.pdf 

Can the 2031VETR switch 24V DC?

No, it is only for 240V~.

For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=2031VETR

Can the 2031VETR be two wayed?

Yes the 2031VETR can have a remote switch wired to it.

For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=2031VETR

Does the 2031VETR switch an exhaust fan?

Yes the 2031VETR will switch small motor loads. (maximum 2A)

For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=2031VETR


 

Does the 2031VETR have dip switches?

Yes, the 2031VETR does have dip switches.

For more information, please refer to the link:
https://www.clipsal.com/Trade/Products/ProductDetail?catno=2031VETR

How does 2031VETF run on timer switch operate?

The Clipsal 2031VETF Series is an electronic time delay switch which provides extended exhaust fan operations to ensure proper ventilation in bathrooms and toilets. It uses a single switch to operate both lighting and an exhaust fan. Both loads switch on simultaneously when the switch is operated, but when the lighting is turned off, the exhaust fan continues to run for several minutes.
Time Delay Intervals Available:
The 201VETF Series is adjustable to allow fans to continue to run from 3 minutes to 10 minutes (approximately) after the lighting is turned off. The delay adjustment is accessible on the rear of the device.
Operation:
Turning on the switch will cause both the lights and the fan to operate. The electronic timer starts when the switch is turned off. The lights are controlled directly by the switch, however, the fan will run for its preset timer period when the lights are turned off. Turning the lights on and off again, while the fan is still running, will cause the timer period to restart.
The fan will activate for a timer cycle whenever power is re-applied to the unit. eg. initial installation, power failure/return, fan replacement.
for further information. please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=2031VETF
User-added image

 

Can part number 2031VETR3 be used in conjunction with air conditioner?

2031VETR3 can be used with air ocnditioner up to 10amps.

 
Show More