Mounting Accessories Wall Boxes Metal, Poured Concrete, 1 Gang

Mounting Accessories Wall Boxes Metal, Poured Concrete, 1 Gang

Mounting Accessories Wall Boxes Metal, Poured Concrete, 1 Gang

Item Number: 160

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Product brand

Clipsal

Surface treatment

electro-galvanized

Sustainable offer status

Green Premium product

Physical

Number of gangs

1 gang

Length

97 mm

Width

50 mm

Depth

39 mm

REACh Regulation

Free of Substances of Very High Concern above the threshold

REACh free of SVHC

Yes

EU RoHS Directive

Pro-active compliance (Product out of EU RoHS legal scope)

Toxic heavy metal free

Yes

Mercury free

Yes

RoHS exemption information

Yes

China RoHS Regulation

 Pro-active China RoHS declaration (out of China RoHS legal scope)

Environmental Disclosure

ENVPEP110719EN

Material

Material

steel

Others

Package 1 Bare Product Quantity

1

Shape

rectangular

Cable entry number

9

Location of connection

rear

Unit Type of Package 1

PCE

Number of Units in Package 1

1

Package 1 Weight

0.143 kg
Show all specifications

Frequently Asked Questions

hide show

What does the Rated short time withstand current (Icw) for the breaker mean?

Rated short time withstand current is the value of short time withstand current, assigned to the equipment by the manufacturer, that the equipment can carry without damage, under the test conditions specified in the relevant product standard.
It's generally expressed in kA for 0.5, 1 or 3 seconds. This is an essential characteristic for air circuit breakers. It is not significant for molded-case circuit breakers for which the design targets fast opening and high limiting capacity.
Icw is different from one breaker to another and its value can be found in the product catalogue.
Masterpact MTZ catalogue
Masterpact NT/NW catalogue

Aveva Edge text display becomes unreadable on high resolution monitors

SUMMARY:
This article explains how to correct display issues for Aveva Edge when run on high resolution monitors.
 
SITUATION: 
Tested on: Aveva Edge 2020 R2, Monitor Resolution (3840 x 2160)
 display issue

ACTION:
Please follow the instructions in the screenshot below. Reboot will be required for changes to take effect.
fix
 

What is the DALI Line Alert indicator mean on the DCBM2-1608

dcbm2-1608

The red Alert (ALT) LED is active only when the Line Controller discovers an error from at least one of the DALI devices being polled for status.

Alert Indicator

 
 

What is the guard for a 22mm push-pull mushroom head operator, similar to cat. no. 9001 K56*M?

Issue:
Identify the part number for a guard for a 22mm push-pull mushroom head operator.

Product Line:
Harmony 22mm, XB4, XB5, Push Buttons

Environment:
Push Buttons and Operator Interface

Resolution:
Catalog number ZBZ160* is a metal guard for 40mm mushroom head operator.
ZBZ1600Chrome Plated
ZBZ1602Black
ZBZ1604Red
ZBZ1605Yellow
ZBZ1606Blue

What are the replacement spring charging motors for the Masterpact NT and NW?

Product Line:
Masterpact NT, Masterpact NW

Resolution:
Spring Charging Motor (MCH)
VoltageT-FrameW- & Y-Frame
FixedDrawoutFixedDrawout
AC
48S47391S47461S48207S48522
100–130S47395S47465S48211S48526
200–240S47396S47466S48212S48527
277S47398S47468S48213S48528
380–415S47398S47468S48214S48529
440–480S47400S47470S48215S48530
DC
24–30S47390S47460S48206S48521
48–60S47391S47461S48207S48522
100–130S47392S47462S48208S48523
200–250S47393S47463S48209S48524


See instruction bulletins,
Spring Charging Motor (MCH) for Masterpact® NT, Electrically-operated P-frame and NS630b–NS1600 Circuit Breakers
48049-236-01
Spring-charging Motor (MCH) for Masterpact® NW Circuit Breakers
48049-149-02

NW
NW Spring charging motor

NT
NT spring charging motor

What can I use to enhance the Modbus signal to my Altivar drive?

Issue:
Enhance Modbus signal for Altivar Drives.

Product Line:
ATV61, ATV71, ATV312, ATV12, ATV320, ATV212, ATV630, ATV930
 
Environment:
All Altivar drives with integrated modbus
 
Cause:
None
 
Resolution:
A device that can be used to enhance the signal on the Modbus network is the TWIDO TWDXCAISO T-junction box.   Please see the attached installation document (1606451_01A55.pdf).
Show More