Single Switch Socket Outlet, 250V, 10A, Removable Extra Switch, Safety Shutter

Single Switch Socket Outlet, 250V, 10A, Removable Extra Switch, Safety Shutter

Single Switch Socket Outlet, 250V, 10A, Removable Extra Switch, Safety Shutter

Item Number: 15XS-WE

Retail
$121.92
RRP (Inc. GST)
Colour White Electric (WE)
  • White Electric 1 PCE

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Product brand

Clipsal

Range of product

Standard Series

Surface finish

glossy

Sustainable offer status

Green Premium product

Physical

Control type

ON/OFF button

Number of gangs

1 gang

Pin number

3

Number of power socket outlets

1

Actuator

  • rocker
  • switch
    • Mounting position

      horizontal

      Fixing mode

      by screws

      Local signalling

      without light indicator

      [Ue] rated operational voltage

      250 V AC

      [In] rated current

      10 A

      Depth

      14 mm

      Length

      115 mm

      Width

      73 mm

      Fixing center

      84 mm

      Standards

    • AS/NZS 3100
    • AS/NZS 3112
    • AS/NZS 3133
    • AS/NZS 3000:approval number S/1
      • EU RoHS Directive

        Compliant

        Mercury free

        Yes

        RoHS exemption information

        Yes

        China RoHS Regulation

        Product out of China RoHS scope. Substance declaration for your information

        Environmental Disclosure

        ENVPEP120506EN

        Material

        Material

        PC (polycarbonate)

        Others

        Unit Type of Package 1

        PCE

        Number of Units in Package 1

        1

        Package 1 Weight

        0.036 kg

        Package 1 Height

        14 mm

        Package 1 width

        73 mm

        Package 1 Length

        115 mm

        Unit Type of Package 2

        BB1

        Number of Units in Package 2

        5

        Package 2 Weight

        5 kg

        Package 2 Height

        117 mm

        Package 2 width

        102 mm

        Package 2 Length

        138 mm

        Unit Type of Package 3

        CAR

        Number of Units in Package 3

        50

        Package 3 Weight

        50 kg

        Package 3 Height

        157 mm

        Package 3 width

        305 mm

        Package 3 Length

        445 mm
        Show all specifications

        Documents & downloads

        hide show
        Filter items
        • All

        • Product Brochures

        • Technical Data Catalogues

        • Specifications

        Frequently Asked Questions

        hide show

        Is the extra switch in the 15X removable?

        Yes, the extra switch in the 15X is removable. Any 230v rated 30 series mec will fit in it's place.

         

        Do you have a 15S in biege?

        No, the 15S only comes in White Electric and Red.

        Some of the key features are:
        • 1 pole
        • Standard size
        • Safety shutter
        For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=15Shttps://www.clipsal.com/Trade/Products/ProductDetail?catno=15S

        What is the maximum DC voltage per pole for TeSys F Range contactors.

        The maximum DC voltage for TeSys F range contactors is 125 Volt per pole. This voltage is applicable for the specification of L/R <= 15ms in DC applications.

        What is the maximum DC voltage per pole for TeSys D range contactors.

        The maximum DC voltage for TeSys D range contactor is 75 Volt per pole. This voltage is applicable for the specification of L/R <= 15ms in DC applications.

        How does the Test Button on the RH99 work?

        When the test push button is activated the switch SW1 is moved on Test position. The measurement of the network is temporarily stopped during 15ms and a sinusoidal signal of 500Hz to simulate a trip is sent to create a current of 100µA inside the resistor R. The signal seen by the toroid sensor is really negligible about the test signal injection.
        During the test signal injection the settings are: Idn = 30mA and tfault = 0.
        At the end of the 15ms delay
        -> if the product trips (TEST OK) the fault LED and the Fault order relay are activated (in case of no trip test only the fault LED is activated). We have to push on the push button Reset to remove the failure create by the test (in case of automatic reset product no action need to remove the failure).
        -> if the product doesn’t trip, no LED, no relay order the TEST is NOK and it means the product doesn’t work.
        After the 15ms of test signal injection the switch SW1 comes back to the measure position and re-starts the monitor of the network with the customer settings (in the front face).
        So if a trip occurs during the test, it will be see directly after the 15ms of test signal injection and it will be impossible to remove the failure state by a push on Reset push button.
         
        The toroids used on the Vigirex range have only one winding inside.   
         
        There is no Calibration procedure for this product. The product is designed to provide the accuracy specified on the catalogue for the product life time.


         

        What is the minimum pulse width or duration required on a IOX or IOC module to register an input status change on the CM4000 series meter?

        Issue
        Minimum pulse or duration required on a IOX or IOC module on a CM4000 series meter

        Product Line
        CM4000 series meter

        Environment
        Hardware Specifications

        Resolution
        The minimal pulse duration per input on the CM4000 IOX or IOC is 15ms when the control power to the meter is DC voltage. For AC voltage to the control power the minimal input pulse duration is 23ms.

        How to set ATS22 to test un unloaded motor?

        Product Line:
        Altistart 22

        Environment:
        Shop tests, unloaded motor

        Cause:
        Testing the ATS with an unloaded motor, usually trips the ATS22 with SSCr.

        Resolution:

        After entering the correct motor data, and set the LAC to ON:

         - t90 = Factory 30 but changed to 10. ( Due to No Load connected and monitor ramp acceleration. This value to be changed back or increased when in the field under actual start-up. )
        - ILt = Factor 350 changed to 200% for Shop Testing. Value to be changed in the field if Current Limit trips out.
        - tLS = Factory 15s changed to 60s for Shop Testing. ( Changed back to 15s after completion of testing. )
        - ACC = Factory 10s change to 60s for Shop Testing. ( Changed back to 10s after completion of testing. )
        - SSC = Factory On, changed to oFF. ( Using Voltage control vs. Torque. )
        - ItH = Found to be on ErUn, changed to On. ( Factory is On. )

         

        NetBotz 250 | Physical Description

        Issue:
           Physical Description of the NetBotz 250.

        Product Line:
           NetBotz Rack Monitor 250 (NBRK0250)

        Environment:
           NetBotz Rack Monitor 250 (all versions)

        Resolution:

        Physical Description



         
        Item Description
        1 AC line inlet Input power connection.
        2 Switched Outlet Provides power to a device at a maximum of 10 A. Activates a connected device when configured events occur. (For example, a fan may be connected to this outlet, and the outlet may be configured to turn on when a high threshold violation occurs for a temperature sensor.)
        3 Wireless Sensor Network USB port with NetBotz USB Coordinator (NBWC100U) installed. Used with included Wireless Temperature Sensor (NBWS100T) to monitor temperature. Additional wireless sensors can be purchased separately. 
        4 Rack Access Ports Ports for the door switch sensors on doors #1 and #2.
        Ports for the handle sensors (NBHN125 or NBHN1356) on doors #1 and #2.
        5 Beacon Port Used for connecting an alarm beacon (AP9324).
        6 Universal Sensor ports Used to connect APC by Schneider Electric sensors and third-party dry contact sensors. Third-party dry contact sensors require a Dry Contact Cable (NBES0304).
        7 USB Port Used to connect USB devices to the appliance.
        8 Voltage Output Provides 12 Vdc or 24 Vdc (75mA) to a connected device.
        Relay Output Used for connecting relay-controlled external devices.
        9 10/100 Network Port Provides the connection to the network. Status and link Light-emitting Diodes (LEDs) indicate network traffic. See Link LED and Status LED for additional information.
        10 A-Link Ports Used to cascade NetBotz Rack Sensor Pod 150s (NBPD0150), or connect Temperature/Humidity Sensors with Digital Display (AP9520TH). Provides communications and power using standard CAT-5 cabling with straight-through wiring.
        NOTE: To cascade multiple devices, connect a supplemental power supply (100-240 Vac/24 Vdc, part number AP9505i) to a NetBotz Rack Sensor Pod 150.
        11 Modbus RS-485 port Provides the connection to a building management system using the Modbus protocol.
        12 Console Port Used to connect the USB A-USB mini B configuration cable, when configuring initial network settings.
        NOTE: See knowledge base FA381239 for instructions on configuring the network settings (TCP/IP) and knowledge base FA381275 for instructions on installing the required FTDI VCP driver.
        13 Power LED Indicates whether the unit is receiving power (blue = receiving power; dark = not receiving power).
        14 Reset button Restarts the Rack Monitor 250 network management interface.

        ION8400 Firmware Features (Public Release Notes) for V261, V244, V240 and V232

         

        New Features in the V261 firmware:

        Firmware version 261 for the ION 8000 series supports the following new features:

        Adds several DNP protocol enhancements, including:

          • DNP supported over Ethernet.
          • Multi-port DNP support for up to three simultaneous connections in any combination of serial and Ethernet.
        Adds IRIG-B* functionality (order option):
          • All IRIG-B equipped meters are configured in the factory to synchronize via GPS using unmodulated IRIG-B time code data.
        *This option requires a receiver capable of unmodulated IRIG-B time code output (not included).

         

        New Features in the V244 firmware:


        Firmware version 244 (V244) for the ION 8500 meter supports the following new features:

          • Adds factory terminal support to choose between Temperature Compensation Algorithm and Crystal Option for the clock.
          • Fixes behaviour... Meter stays in test mode through power cycle with advanced securities enabled.


        New Features in the V240 firmware:

        Networking and Internet Connectivity
          • More robust and stable TCP/IP stack is introduced.
          • New configurable Web Pages are introduced.
          • Log Mail module has been replaced by the Log Export module, which sends log data in an XML format that is compatible with the MeterMail Archive.
        Rapid Meter Programming

        Rapid Meter Programming dramatically reduces the time required to complete a framework upgrade operation in ION 8000 series. It allows customers to load a complete custom framework into an ION device in approximately 5 minutes over a 9600-baud serial connection. For this feature to operate there must be a compatible version of ION Setup.

        Instrument Transformer Correction Module

        The Instrument Transformer Correction module is a core module that allows customers to correct for inaccuracies in the current transformers (CTs) and potential transformers (PTs). There is an Instrument Transformer Correction module for each current and voltage input into the meter.

        The primary application for instrument transformer correction is to apply correction factors for ratio errors and phase angle errors to instrument transformers. Instrument transformer correction reduces or eliminates the need to replace transformers in installations where high-accuracy is required.

        Integrator Module

        Version V240 allows Integrator modules to count by steps (every 15 minutes) to allow more accurate validation in MV90.

        Operations/Control

        Resetting battery counters through ION Setup, or ION Designer is provided.

        Harmonic Measurements

        Enhancements made to the Harmonics Measurement Module (HME):

          • An evaluate input to be pulsed at 15s or 10 minute intervals to perform RMS averaging according to IEC (6)1000-4-7.
          • A setup register for selecting whether the values are provided in engineering units or percentage of the fundamental.
          • A setup register for specifying, if the Evaluate input is linked, whether the output values represent the maximum of the 'TVS values' or the average of the 'TVS values'.
        Sag/Swell Event Monitoring

        If sag/swell event is accompanied with an power outage event, the sag/swell module now reports the sag/swell info as well as the actual outage duration.

        The V240 release also fixes, or improves the following:

          • The output register named as "Battery Minutes" in ION Diagnostic Module is renamed as "Battery Remaining".
          • Alert Module Trigger pulses occurred first 30 seconds during start up will not be ignored.
          • Alert Module - Alert will accept control commands <CR><LF>.
          • Demand Update - Predicted Demand calculated correctly now in "Every Second" mode.
          • Demand Update - Output timestamps is now updated in "Every Second" mode.
          • DNP number of output handles returned is now correct.
          • 10 New Counter Modules added.
          • Configurable receive timeout is added to Ethernet COMs.
          • 5 New External Boolean Modules.
          • Initialization of Digital Inputs is corrected. Prior to V240, if the digital inputs are ON during startup, the meter reports incorrect transitions on digital inputs.


        New Features in V232 firmware:
          • Support for time and date formats in the display modules, enabling displays with nothing but date and/or time and/or time remaining in the current demand interval.
          • Improved disk simulator
          • A new Ethernet port option on ION 8300 meters.
          • Enhanced Test Functions when using Transformer Loss Compensation. Easier meter testing is now possible because the addition of a single-phase TLC (transformer loss compensation) algorithm meaning users can run the meter in Test Mode using a single phase test set rather than having to use a three phase test set.
          • Improved Logging on Power Outages. Customers can now choose an option that determines how the meter handles logged information after a power outage condition.
          • Variable update rate for demand values - the Sliding Window/Rolling Block module has a new setup register "Update Rate" that defines the update rate of the SWin Demand output register. Updates can be made at the end of each sub-interval or every second. Updates every second are required for Demand Forgiveness functionality. For more information, refer to the Sliding Window module description in the online ION Programmers Reference.
         

         Note:
        Since V231 ION 8000 series firmware has contained advanced security. Pegasys users must NOT enable this feature as you will no longer be able to communicate to the meter. The Advanced Security feature is designed to work with ION Enterprise and ION Setup.

         



        Legacy KB System (APS) Data: RESL205236 V1.0, Originally authored by DaMi on 04/30/2011, Last Edited by DaMi on 04/30/2011
        Related ranges: ION8400

        ION8300 Firmware Features (Public Release Notes) for V261, V244, V240 and V232

         

        ION8300 Firmware Features

        Note:
        Since V231 ION 8000 series firmware has contained advanced security. Pegasys users must NOT enable this feature as you will no longer be able to communicate to the meter. The Advanced Security feature is designed to work with ION Enterprise and ION Setup.

         


        New Features in the V261 firmware:

        Firmware version 261 for the ION 8000 series supports the following new features:

        Adds several DNP protocol enhancements, including:

          • DNP supported over Ethernet.
          • Multi-port DNP support for up to three simultaneous connections in any combination of serial and Ethernet.
        Adds IRIG-B* functionality (order option):
          • All IRIG-B equipped meters are configured in the factory to synchronize via GPS using unmodulated IRIG-B time code data.
        *This option requires a receiver capable of unmodulated IRIG-B time code output (not included).

        New Features in the V244 firmware:


        Firmware version 244 (V244) for the ION 8500 meter supports the following new features:

          • Adds factory terminal support to choose between Temperature Compensation Algorithm and Crystal Option for the clock.
          • Fixes behaviour... Meter stays in test mode through power cycle with advanced securities enabled.

        New Features in the V240 firmware:

        Networking and Internet Connectivity
          • More robust and stable TCP/IP stack is introduced.
          • New configurable Web Pages are introduced.
          • Log Mail module has been replaced by the Log Export module, which sends log data in an XML format that is compatible with the MeterMail Archive.
        Rapid Meter Programming

        Rapid Meter Programming dramatically reduces the time required to complete a framework upgrade operation in ION 8000 series. It allows customers to load a complete custom framework into an ION device in approximately 5 minutes over a 9600-baud serial connection. For this feature to operate there must be a compatible version of ION Setup.

        Instrument Transformer Correction Module

        The Instrument Transformer Correction module is a core module that allows customers to correct for inaccuracies in the current transformers (CTs) and potential transformers (PTs). There is an Instrument Transformer Correction module for each current and voltage input into the meter.

        The primary application for instrument transformer correction is to apply correction factors for ratio errors and phase angle errors to instrument transformers. Instrument transformer correction reduces or eliminates the need to replace transformers in installations where high-accuracy is required.

        Integrator Module

        Version V240 allows Integrator modules to count by steps (every 15 minutes) to allow more accurate validation in MV90.

        Operations/Control

        Resetting battery counters through ION Setup, or ION Designer is provided.

        Harmonic Measurements

        Enhancements made to the Harmonics Measurement Module (HME):

          • An evaluate input to be pulsed at 15s or 10 minute intervals to perform RMS averaging according to IEC (6)1000-4-7.
          • A setup register for selecting whether the values are provided in engineering units or percentage of the fundamental.
          • A setup register for specifying, if the Evaluate input is linked, whether the output values represent the maximum of the 'TVS values' or the average of the 'TVS values'.
        Sag/Swell Event Monitoring

        If sag/swell event is accompanied with an power outage event, the sag/swell module now reports the sag/swell info as well as the actual outage duration.

        The V240 release also fixes, or improves the following:

          • The output register named as "Battery Minutes" in ION Diagnostic Module is renamed as "Battery Remaining".
          • Alert Module Trigger pulses occurred first 30 seconds during start up will not be ignored.
          • Alert Module - Alert will accept control commands <CR><LF>.
          • Demand Update - Predicted Demand calculated correctly now in "Every Second" mode.
          • Demand Update - Output timestamps is now updated in "Every Second" mode.
          • DNP number of output handles returned is now correct.
          • 10 New Counter Modules added.
          • Configurable receive timeout is added to Ethernet COMs.
          • 5 New External Boolean Modules.
          • Initialization of Digital Inputs is corrected. Prior to V240, if the digital inputs are ON during startup, the meter reports incorrect transitions on digital inputs.


        New Features in V232 firmware:
          • Support for time and date formats in the display modules, enabling displays with nothing but date and/or time and/or time remaining in the current demand interval.
          • Improved disk simulator
          • A new Ethernet port option on ION 8300 meters.
          • Enhanced Test Functions when using Transformer Loss Compensation. Easier meter testing is now possible because the addition of a single-phase TLC (transformer loss compensation) algorithm meaning users can run the meter in Test Mode using a single phase test set rather than having to use a three phase test set.
          • Improved Logging on Power Outages. Customers can now choose an option that determines how the meter handles logged information after a power outage condition.
          • Variable update rate for demand values - the Sliding Window/Rolling Block module has a new setup register "Update Rate" that defines the update rate of the SWin Demand output register. Updates can be made at the end of each sub-interval or every second. Updates every second are required for Demand Forgiveness functionality. For more information, refer to the Sliding Window module description in the online ION Programmers Reference.
         

        Legacy KB System (APS) Data: RESL205238 V1.0, Originally authored by DaMi on 04/30/2011, Last Edited by DaMi on 04/30/2011
        Related ranges: ION8300

        ION8500 Firmware Features (Public Release Notes) for V261, V244, V240 and V232

        New Features in the V261 firmware:

        Firmware version 261 for the ION 8000 series supports the following new features:

        Adds several DNP protocol enhancements, including:

          • DNP supported over Ethernet.
          • Multi-port DNP support for up to three simultaneous connections in any combination of serial and Ethernet.
        Adds IRIG-B* functionality (order option):
          • All IRIG-B equipped meters are configured in the factory to synchronize via GPS using unmodulated IRIG-B time code data.
        *This option requires a receiver capable of unmodulated IRIG-B time code output (not included).



        New Features in the V244 firmware:

        Firmware version 244 (V244) for the ION 8500 meter supports the following new features:

          • Adds factory terminal support to choose between Temperature Compensation Algorithm and Crystal Option for the clock.
          • Fixes behaviour... Meter stays in test mode through power cycle with advanced securities enabled.



        New Features in the V240 firmware:

        Networking and Internet Connectivity
          • More robust and stable TCP/IP stack is introduced.
          • New configurable Web Pages are introduced.
          • Log Mail module has been replaced by the Log Export module, which sends log data in an XML format that is compatible with the MeterMail Archive.
        Rapid Meter Programming

        Rapid Meter Programming dramatically reduces the time required to complete a framework upgrade operation in ION 8000 series. It allows customers to load a complete custom framework into an ION device in approximately 5 minutes over a 9600-baud serial connection. For this feature to operate there must be a compatible version of ION Setup.

        Instrument Transformer Correction Module

        The Instrument Transformer Correction module is a core module that allows customers to correct for inaccuracies in the current transformers (CT’s) and potential transformers (PT’s). There is an Instrument Transformer Correction module for each current and voltage input into the meter.

        The primary application for instrument transformer correction is to apply correction factors for ratio errors and phase angle errors to instrument transformers. Instrument transformer correction reduces or eliminates the need to replace transformers in installations where high-accuracy is required.

        Integrator Module

        Version V240 allows Integrator modules to count by steps (every 15 minutes) to allow more accurate validation in MV90.

        Operations/Control

        Resetting battery counters through ION Setup, or ION Designer is provided.

        Harmonic Measurements

        Enhancements made to the Harmonics Measurement Module (HME):

          • An evaluate input to be pulsed at 15s or 10 minute intervals to perform RMS averaging according to IEC (6)1000-4-7.
          • A setup register for selecting whether the values are provided in engineering units or percentage of the fundamental.
          • A setup register for specifying, if the Evaluate input is linked, whether the output values represent the maximum of the 'TVS values' or the average of the 'TVS values'.
        Sag/Swell Event Monitoring

        If sag/swell event is accompanied with an power outage event, the sag/swell module now reports the sag/swell info as well as the actual outage duration.

        The V240 release also fixes, or improves the following:

          • The output register named as "Battery Minutes" in ION Diagnostic Module is renamed as "Battery Remaining".
          • Alert Module – Trigger pulses occurred first 30 seconds during start up will not be ignored.
          • Alert Module - Alert will accept control commands <CR><LF>.
          • Demand Update - Predicted Demand calculated correctly now in "Every Second" mode.
          • Demand Update - Output timestamps is now updated in "Every Second" mode.
          • DNP – number of output handles returned is now correct.
          • 10 New Counter Modules added.
          • Configurable receive timeout is added to Ethernet COM’s.
          • 5 New External Boolean Modules.
          • Initialization of Digital Inputs is corrected. Prior to V240, if the digital inputs are ON during startup, the meter reports incorrect transitions on digital inputs.



        New Features in V232 firmware:
          • Support for time and date formats in the display modules, enabling displays with nothing but date and/or time and/or time remaining in the current demand interval.
          • Improved disk simulator
          • A new Ethernet port option on ION 8300 meters.
          • Enhanced Test Functions when using Transformer Loss Compensation. Easier meter testing is now possible because the addition of a single-phase TLC (transformer loss compensation) algorithm meaning users can run the meter in Test Mode using a single phase test set rather than having to use a three phase test set.
          • Improved Logging on Power Outages. Customers can now choose an option that determines how the meter handles logged information after a power outage condition.
          • Variable update rate for demand values - the Sliding Window/Rolling Block module has a new setup register "Update Rate" that defines the update rate of the SWin Demand output register. Updates can be made at the end of each sub-interval or every second. Updates every second are required for Demand Forgiveness functionality. For more information, refer to the Sliding Window module description in the online ION Programmers Reference.
         

        Note:
        Since V231 ION 8000 series firmware has contained advanced security. Pegasys users must NOT enable this feature as you will no longer be able to communicate to the meter. The Advanced Security feature is designed to work with ION Enterprise and ION Setup.