Single Switch Socket Outlet, 250V, 10A, Standard Size, Vertical, Safety Shutter

Catalogue Number: 15VS
sock swt sing vert 10a shutt
Retail
$82.36
RRP (Inc. GST)
Colour White Electric (WE)
  • White Electric 1 PCE

Specifications

hide show
Product brand
Clipsal
Range of product
Standard Series
Control type
ON/OFF button
Number of gangs
1 gang
Pin number
3
Number of power socket outlets
1
Actuator
  • switch
  • rocker
    • Mounting position
      vertical
      Fixing mode
      by screws
      Local signalling
      without light indicator
      Material
      PC (polycarbonate)
      Surface finish
      glossy
      [Ue] rated operational voltage
      250 V AC
      [In] rated current
      10 A
      Depth
      14 mm
      Length
      115 mm
      Width
      73 mm
      Fixing center
      84 mm
      Standards
    • AS/NZS 3100
    • AS/NZS 3112
    • AS/NZS 3133
    • AS/NZS 3000:approval number S/1
      • Unit Type of Package 1
        PCE
        Number of Units in Package 1
        1
        Package 1 Weight
        0.082 kg
        Package 1 Height
        14 mm
        Package 1 width
        73 mm
        Package 1 Length
        115 mm
        Unit Type of Package 2
        BB1
        Number of Units in Package 2
        10
        Package 2 Weight
        0.82 kg
        Package 2 Height
        118 mm
        Package 2 width
        148 mm
        Package 2 Length
        167 mm
        Unit Type of Package 3
        CAR
        Number of Units in Package 3
        100
        Package 3 Weight
        8.2 kg
        Package 3 Height
        254 mm
        Package 3 width
        348 mm
        Package 3 Length
        445 mm
        Sustainable offer status
        Green Premium product
        EU RoHS Directive
        Compliant
        Mercury free
        Yes
        RoHS exemption information
        Yes
        China RoHS Regulation
        Product out of China RoHS scope. Substance declaration for your information
        Environmental Disclosure
        ENVPEP120506EN

        Documents & downloads

        hide show
        Filter items
        • All

        • Product Brochures

        • Technical Data Catalogues

        Frequently Asked Questions

        hide show

        What is the inrush current of a LC1D40U7 Contactor?

        It is 160VA inrush and 15VA sealed at 50HZ for the LC1D40U7 Contactor.
        For more information see data sheet https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=lc1d40u7

        Do you have a 15S in biege?

        No, the 15S only comes in White Electric and Red.

        Some of the key features are:
        • 1 pole
        • Standard size
        • Safety shutter
        For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=15Shttps://www.clipsal.com/Trade/Products/ProductDetail?catno=15S

        What is the maximum DC voltage per pole for TeSys F Range contactors.

        The maximum DC voltage for TeSys F range contactors is 125 Volt per pole. This voltage is applicable for the specification of L/R <= 15ms in DC applications.

        What is the maximum DC voltage per pole for TeSys D range contactors.

        The maximum DC voltage for TeSys D range contactor is 75 Volt per pole. This voltage is applicable for the specification of L/R <= 15ms in DC applications.

        How does the Test Button on the RH99 work?

        When the test push button is activated the switch SW1 is moved on Test position. The measurement of the network is temporarily stopped during 15ms and a sinusoidal signal of 500Hz to simulate a trip is sent to create a current of 100µA inside the resistor R. The signal seen by the toroid sensor is really negligible about the test signal injection.
        During the test signal injection the settings are: Idn = 30mA and tfault = 0.
        At the end of the 15ms delay
        -> if the product trips (TEST OK) the fault LED and the Fault order relay are activated (in case of no trip test only the fault LED is activated). We have to push on the push button Reset to remove the failure create by the test (in case of automatic reset product no action need to remove the failure).
        -> if the product doesn’t trip, no LED, no relay order the TEST is NOK and it means the product doesn’t work.
        After the 15ms of test signal injection the switch SW1 comes back to the measure position and re-starts the monitor of the network with the customer settings (in the front face).
        So if a trip occurs during the test, it will be see directly after the 15ms of test signal injection and it will be impossible to remove the failure state by a push on Reset push button.
         
        The toroids used on the Vigirex range have only one winding inside.   
         
        There is no Calibration procedure for this product. The product is designed to provide the accuracy specified on the catalogue for the product life time.


         

        What is the minimum pulse width or duration required on a IOX or IOC module to register an input status change on the CM4000 series meter?

        Issue
        Minimum pulse or duration required on a IOX or IOC module on a CM4000 series meter

        Product Line
        CM4000 series meter

        Environment
        Hardware Specifications

        Resolution
        The minimal pulse duration per input on the CM4000 IOX or IOC is 15ms when the control power to the meter is DC voltage. For AC voltage to the control power the minimal input pulse duration is 23ms.

        How does the shield connection of the comm port on ION8600/8650 connect to earth ground?

        The RS485 shield is connected to earth ground through a 120ohm resistor.
        The RS232 shield is connected to earth ground through a 15V sidactor, 1Mohm resistor, and a 1nF capacitor.


        Legacy KB System (APS) Data: RESL209509 V1.0, Originally authored by MaTh on 10/27/2012, Last Edited by MaTh on 10/27/2012
        Related ranges: ION8650, ION8600

        Communication Gateway - What pins are what on the RS485 (Modbus) Terminal Block? (eg. Rx+, Rx-, Tx+ and correct orientation)

        Pin 1 - 15V input
        Pin 2 - Ground
        Pin 3 - RS485 A
        Pin 4 - RS485 B
         
        RS485 is a bidirectional differential bus so there is no transmit and receive. Pin 1 is on the right when looking at the connector. See attached diagram.
         

        How to power a Xantrex System Control Panel when no XW+ or SW is present?

        When using a Xantrex System Control Panel, this unit is powered from either an XW+ or an SW hybrid inverter.

        When in a situation that either one of these hybrid inverters are not available, to get the SCP to operate, you will need to provide an independant 15V DC 200mA supply to the Xanbus network.

        +ve should be connected straight to pins 1,2 and 7. -ve should be connected to 3, 6 and 8.

        How to set ATS22 to test un unloaded motor?

        Product Line:
        Altistart 22

        Environment:
        Shop tests, unloaded motor

        Cause:
        Testing the ATS with an unloaded motor, usually trips the ATS22 with SSCr.

        Resolution:

        After entering the correct motor data, and set the LAC to ON:

         - t90 = Factory 30 but changed to 10. ( Due to No Load connected and monitor ramp acceleration. This value to be changed back or increased when in the field under actual start-up. )
        - ILt = Factor 350 changed to 200% for Shop Testing. Value to be changed in the field if Current Limit trips out.
        - tLS = Factory 15s changed to 60s for Shop Testing. ( Changed back to 15s after completion of testing. )
        - ACC = Factory 10s change to 60s for Shop Testing. ( Changed back to 10s after completion of testing. )
        - SSC = Factory On, changed to oFF. ( Using Voltage control vs. Torque. )
        - ItH = Found to be on ErUn, changed to On. ( Factory is On. )

         

        NetBotz 250 | Physical Description

        Issue:
           Physical Description of the NetBotz 250.

        Product Line:
           NetBotz Rack Monitor 250 (NBRK0250)

        Environment:
           NetBotz Rack Monitor 250 (all versions)

        Resolution:

        Physical Description



         
        Item Description
        1 AC line inlet Input power connection.
        2 Switched Outlet Provides power to a device at a maximum of 10 A. Activates a connected device when configured events occur. (For example, a fan may be connected to this outlet, and the outlet may be configured to turn on when a high threshold violation occurs for a temperature sensor.)
        3 Wireless Sensor Network USB port with NetBotz USB Coordinator (NBWC100U) installed. Used with included Wireless Temperature Sensor (NBWS100T) to monitor temperature. Additional wireless sensors can be purchased separately. 
        4 Rack Access Ports Ports for the door switch sensors on doors #1 and #2.
        Ports for the handle sensors (NBHN125 or NBHN1356) on doors #1 and #2.
        5 Beacon Port Used for connecting an alarm beacon (AP9324).
        6 Universal Sensor ports Used to connect APC by Schneider Electric sensors and third-party dry contact sensors. Third-party dry contact sensors require a Dry Contact Cable (NBES0304).
        7 USB Port Used to connect USB devices to the appliance.
        8 Voltage Output Provides 12 Vdc or 24 Vdc (75mA) to a connected device.
        Relay Output Used for connecting relay-controlled external devices.
        9 10/100 Network Port Provides the connection to the network. Status and link Light-emitting Diodes (LEDs) indicate network traffic. See Link LED and Status LED for additional information.
        10 A-Link Ports Used to cascade NetBotz Rack Sensor Pod 150s (NBPD0150), or connect Temperature/Humidity Sensors with Digital Display (AP9520TH). Provides communications and power using standard CAT-5 cabling with straight-through wiring.
        NOTE: To cascade multiple devices, connect a supplemental power supply (100-240 Vac/24 Vdc, part number AP9505i) to a NetBotz Rack Sensor Pod 150.
        11 Modbus RS-485 port Provides the connection to a building management system using the Modbus protocol.
        12 Console Port Used to connect the USB A-USB mini B configuration cable, when configuring initial network settings.
        NOTE: See knowledge base FA381239 for instructions on configuring the network settings (TCP/IP) and knowledge base FA381275 for instructions on installing the required FTDI VCP driver.
        13 Power LED Indicates whether the unit is receiving power (blue = receiving power; dark = not receiving power).
        14 Reset button Restarts the Rack Monitor 250 network management interface.

        My customer have a Siemens motor nr: 1PH7 107-xxFxx-x The encoder on this motor is of the type HTL-signal, 15VDC. Do we have any encodercard that supp...

        Goals and Symptoms

        My customer have a Siemens motor nr: 1PH7 107-xxFxx-x The encoder on this motor is of the type HTL-signal, 15VDC. Do we have any encoder card that support this kind of encoder "HTL signal" for the ATV71?

        Causes and Fixes

        The HTL is a type of Push Pull, then VW3A3405 or 06 or 07 option board depend the alimentation, can work without any problem on the HTL encoder. So be carreful you have to verrify the current consomation of your encoder in accordance to 175ma maximum up to 15V and 100ma up to 24V. Or you can add a external alimentation.

        In the ATV71 catalogue the low level is < 1,5V, not compatible with HTL but this value is false, in reality we guarantee a low level <3V, 100% compatible with HTL technologie <2,8V.


        Legacy KB System (APS) Data: RESL176046 V1.0, Originally authored by on , Last Edited by GiVa on 11/07/2006
        Related ranges: Altivar 71
        Show More