bracket mtg 1g mini plaster

Mounting Accessories Metal Plaster Bracket to Suit Intermediate Plates

Catalogue Number: 155PM
bracket mtg 1g mini plaster
Colour:
Colour: Per UOM Std.
  • 1 PCE

Specifications

hide show
Product brand
Clipsal
Product or component type
bracket
Accessory / separate part category
mounting accessory
Shape
square
Fixing center
84 mm
Depth
3 mm
Length
152 mm
Width
152 mm
Material
metal
EU RoHS Directive
Pro-active compliance (Product out of EU RoHS legal scope)
Toxic heavy metal free
Yes
Mercury free
Yes
RoHS exemption information
Yes
China RoHS Regulation
 Pro-active China RoHS declaration (out of China RoHS legal scope)
Circularity Profile
N/A

Documents & downloads

hide show
Filter items
  • All

  • CAD Files and Packs

  • Product Brochures

  • Technical Data Catalogues

  • Installation Instruction

  • Specifications

  • Certificates (MSDS)

Frequently Asked Questions

hide show

What is the plaster bracket to suit the P2025?

The part name is 155P2

What is part number for bracket to suit BSL31VA?

The part number for bracket to suit is 155P.

What are the dimensions of the INS400 single handle transfer switch 31150?

205mm x 395mm x 155mm (H x W x D) excluding the handle.
Overall depth with standard handle is 213mm.
See attached.

What are the outside dimensions of the FPSS121-CAT6?

The dimensions are 121mm (W) X 83mm (H) X 155mm (D).

Will 25/2V double outlet, large size, vertical fit on 155P2 plaster bracket?

Yes, 25/2V will fit on 155P2. 25/2V is  Large Size Format 115 x 115mm, Double Power Outlet rated to 250V 10A.
For further information please visit:
https://www.clipsal.com/Trade/Products/ProductDetail?catno=25/2V
User-added image

155P2 is a large plaster mounting bracket with 84mm mounting centre. For further information please visit:
https://www.clipsal.com/Trade/Products/ProductDetail?catno=155P2
User-added image
 

Is there a bracket to mount sockets onto Actassi trucking?

You can direct mount onto the lid of the 80 or 155mm trunking or use the ISM15150

Other options are the Unistrut 2087016 and adaptors can also be found at cccutting.co.nz

What would be the Wall plate (plaster) to suit Prestige large switches?

The wall plate would be the 155P2.

Please go to the website via the following link www.clipsal.com/Trade/Products/ProductDetail  and check under the Documentation Tab for more information.

Will 755PFM photoelectric alarm fit in the existing base of 755FM ionization alarm?

Yes. 755PFM photoelectric alarm can be fitted on to the existing base of 755FM ionization smoke alarm.
For further information of 755PFM, please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=755PFM

What is part number for 115mm x 115mm large mounting flange?

Part number for large mounting flange is 448SD

What is the Cut-Out Hole Size or Mounting Hole Size for a Clipsal 755PFM and 755FM

 It is 90mm.
See attached pdf for more information.

The installation sheet for 755FM is available at :  https://updates.clipsal.com/ClipsalOnline/Files/Brochures/W0000802.pdf

The installation sheet for 755PFM is available at:  https://updates.clipsal.com/ClipsalOnline/Files/Brochures/W0000801.pdf

What is the part Number for the Clipsal Flush mounted smoke detector ?

The part number is 755PFM for photoelectric type and 755FM for Ionisation

Please find attached pdf on these alarms

For further information please visit the Clipsal Web site on the link provided.
https://www.clipsal.com/Trade/search-results?q=755p

Can the 155H2 be used with the 2025H2 series ?

No, the 155H2 mounting bracket can not be used with the 2025H2 as the mounting holes do not line up. You can use a wall clip part number 2154/4.

For further information please visit https://updates.clipsal.com/ClipsalOnline/Files/Brochures

 

what is the cutout size for the 755FM ?

 
 
 
 
The 755FM and 755PFM have a 90mm cut out
For more information on the 755 range of smoke alarms please visit the Clipsal web site on the link provided
https://www.clipsal.com/Trade/search-results?q=755

Is there a Secondary Power Supply for the Clipsal 755PFM and 755FM smoke alarms

 Yes there is a secondary power supply it is 9V DC alkaline battery backup

How far is the 755PFM recessed?

The recess on our 755PFM is 80mm.

What is the part code for a 1P 32A relay

 The part code is 15515

What is the dimensions for a PDL 535WH

 Dimensions -  158mm x 158mm x 140mm high.

What is the diameter for the Clipsal 755PSM smoke alarm

The diameter is 140mm

What size duct does a 135mm, drop in lid suit in the Moduline range?

The 135mm drop in lid would suit the 150mm duct however all drop in products have been obsolete for a at least 2 years.

What Series is the 154RM C-Clip, plaster bracket for?

That bracket will suit the slimline, Saturn, ZEN and OneTouch series plates.

What is the part code for a pulse relay 16Amp 2P 240V ac coil voltage

Use a 15520

What is the dimension of the PDL 90 - Ceiling Mounting Ball Light?

175mm diameter ball

What is the acti 9 equivelant of the 15512

The part code is A9C30211

What is the meaning of the Speed-range ratio in Altivar 61/71 Range Drives.

The Speed-range ratio for Drives is 20:1, 100:1 or 1000:1. This is an indication of how slow the Drive can run the motor, before the motor starts to overheat.

Drive with a 1000:1 ratio is good, as compared to 20:1 or 100:1.
 
The Altivar 61 and Altivar 71 Range of Drives have the Speed-range ratio of 1000:1 in closed loop and 100:1 in open loop operation.
 
Example:
 
The speed in RPM (Revolutions per Minute) of a 4 pole, 50 Hz Motor will be 1500 RPM.
 
If the Drive Speed-range is 1000:1, Drive can run the motor as slow as 1.5 RPM (1500/1000 = 1.5) without overheating.
 
For 100:1 it is 15rpm and for 20:1 it is 75rpm.
 
The higher the Speed-range ratio, the slower the motor can be operated safely without overheating.

What wall clip is used for Prestige large format plates?

The 154/2 is the clip to suit any Prestige large format plate 115mm x 115mm

What is the cut out for 755PFM smoke alarm?

The cut out is 90mm diameter

What is the part number for a metal plate range double GPO on plate that is 115mm x 115mm?

The part number for a metal plate range double GPO on plate that is 115mm x 115mm is - B15V2A

For further information , visit link below:-
https://www.clipsal.com/Trade/search-results?q=B15V2A
User-added image

Can you get a double GPO that is bigger than the standard 115mm x 85mm?

Yes, there are a couple of options that are bigger than the standard 115mm x 85mm. 
There is the P2025/2-WE, M8015LVA-WE or M8025LVA-WE.

Do you have an active link that takes 185mm cable?

No, unfortunately we don't have an active link that takes 185mm cable.
The largest we have is the L13/150R which accommodates 2 x 150sq mm.

Some of the key features are:
  • 13 hole Front wiring
  • Red base and cover

For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=L13/150R
 

 

Is the Clipsal 755PFM smoke alarm photoelectric

Yes it is

What are the dimensions for the 4CS12FD?

The dimensions are 315mm W x 255mm H x 97mm D
 

What are the dimensions for part number C2016/2?

The dimensions for part number C2016/2 are:
159mm (L)  47mm (H) 28mm (D)

What is the Length of LV432598?

The length is 195mm - 600mm to back of door from the base, where the breaker is mounted.
For more information please see the instruction sheet .....https://www.schneider-electric.com.au/sites/australia/en/support/substitution-tool/substitution-tool.page..
 

What is part number for 150mm 2m cable cover?

Part number is 287/150

Is it possible to test several 755FM units which are all interconnected?

Hold the test button down for about 10-15 seconds and other smoke alarms on circuit should go off

Does the 755FM smoke alarm comply with AS3786

Yes it complies with AS3786 and also AS/NZS3100

What are the part numbers required to make data kit and power kit for moduline Tal Plus duct ?

data kit is made of 2 part nos
> PLDSK (which is the Shroud) and then front cover PL125CFCx (x will be the color N,B,W,O) > this is for 125mm duct
> PLDSK (which is the Shroud) and then front cover PL150CFCx (x will be the color N,B,W,O) > this is for 150mm duct

power kit is made of 2 part nos
> PLPSK (which is the Shroud) and then front cover PL125CFCx (x will be the color N,B,W,O) > this is for 125mm duct
> PLPSK (which is the Shroud) and then front cover PL150CFCx (x will be the color N,B,W,O) > this is for 150mm duct
 

What is the dimensions for the PDL range of cover plates

The single cover plate is 118 x 74mm
The double cover which covers two subplates plates is 118mm x 145mm

What are the Dimensions for the PDL DBPS96 Switchboard ?

Board Size: 780mm H x 555mm W x 186mm D
Weight: with Metal Door 21kg, with Glass Door 21.4kg

Dimensions of the Clipsal 155PRM, Metal Mounting Bracket, for plaster walls?

152 Length x 152 Width x 10 Depth mm
Mounting centre 84mm

what is the Acti 9 code for Merlin Gerin 15515?

A9C30831 is the Acti9 code for the 1P 1NO 32A 230v AC impulse relay.

What are the dimensions of part number 750MBA?

The dimensions for part number 750MBA are:

145mm (L) x 90mm (W) x 45mm (D)

What is the Cut-out hole size for a 755PFM Flush mount smoke alarm?

The Cut-out hole size for a 755PSM flush mount smoke alarm is 90mm.

Some of the key features are:

  • Photoelectric technology for faster response to common smouldering fires
  • Super low profile, stylish fully recessed design (60% smaller than the average smoke alarm)
  • Easy installation and maintenance using a 90mm cut out and clip in/clip out module
  • Interconnectable with up to 40 units (compatible with all Clipsal Firetek smoke alarms)
  • Built in test/hush function
  • 9VDC battery backup (included)
For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=755PFM


User-added image

Is there a wireless interconnect base for the flush mount 755PFM ?

No. Unfortunately, there is currently no base available with wireless interconnect to suit the 755PFM flush series of smoke alarm. 

What is the difference between the Surge Arresters reference 15597 and 16447

The difference between the Surge Arrester references 15597 and 16447 is as follows:

1.) 15597 is a PF20 3Pole Fixed type Type 2 LV Surge Arrester.
2.) 16447 is a PRD20 3Pole Withdrawable type Type 2 LV Surge Arrester. 

Both are suitable to be used in low risk level and for use in TNC Earthing systems.

The difference is that 15597 at its end of life needs to be replaced as it is Fixed type, while 16447 at its end of life can be reused by simply replacing the cartridge as it is Withdrawable type, and the other major advantage is that the wiring does not get disturbed.

Whati s pitch thread for part number 1245/25?

Pitch thread is 1.5mm

What is the part numbers for the 125mm clip on lid to go with PL35125DN?

The part numbers for the 125mm clip on lid that goes with PL35125DN is PL125CLN.

For further information please visit https://www.clipsal.com/Trade/search-results?q=PL125CLN

What is the part number of the mounting block to suit 31/3VX, 162 x 115mm blank switch plate?

Unfortunately we do not have a mounting block  to suit 31/3VX, large format blank switch plate.

Will the 9001KA contact blocks work at 24VDC?

Issue:
Will the 9001KA contact blocks work at 24VDC?

Product Line:
Harmony Pushbuttons

Environment:
All Products

Cause:
Product Features

Resolution:
9001 KA1-KA6, KA21-25, KA31-35, KA1G-KA6 contact blocks will work on 24VDC providing the do not exceed 1.1amp make and break nor exceed 10 amps continuous current.


CTA-ID : 15554

What are the dimensions for the Clipsal 755SMA Smoke Alarm?

Please see attached document and drawing.
Show More