bracket mtg 1g std plaster

Metal Plaster Mounted Bracket to Suit Rendered Plaster Walls, 1 Gang

Catalogue Number: 155P
bracket mtg 1g std plaster
Retail
$9.61
RRP (Inc. GST)

Specifications

hide show
Product brand
Clipsal
Product or component type
bracket
Accessory / separate part category
mounting accessory
Shape
square
Fixing center
84 mm
Depth
3 mm
Length
152 mm
Width
152 mm
Material
metal
Package 1 Weight
0.099 kg
Package 1 Height
10 mm
Package 1 width
152 mm
Package 1 Length
152 mm
EU RoHS Directive
Pro-active compliance (Product out of EU RoHS legal scope)
Toxic heavy metal free
Yes
Mercury free
Yes
RoHS exemption information
Yes
China RoHS Regulation
 Pro-active China RoHS declaration (out of China RoHS legal scope)

Frequently Asked Questions

hide show

What is part number for Optiline 70 skirting duct 155x 55?

The part number for Optiline 70 skirting duct 155x 55 is a - ISM11450

For more information on this part please refer to https://www.clipsal.com/Trade/Products/ProductDetail?catno=ISM11450


User-added image

Read a LXM32 drive ramp (ACC, DEC) using SoMachine

Issue:
How to read a LXM32 drive ramp (ACC, DEC) using SoMachine?

Product Line:
Lexium 32

Resolution:
To read the drive ramp values (ACC, DEC), you can use the function block "MC_ReadParameter".
This function block requires the modbus address of the parameter in the input "Address".
ParameterNumber must be set to 1000 (Default value).
1556 = RAMP_v_acc
1558 = RAMP_v_dec

Using GetAttributeSingle would also work. In this case, the CIP address should be used (can be found in the LXM32M manual).
CIP 106.1.10 = RAMP_v_acc
CIP 106.1.11 = 1558 = RAMP_v_dec

What is the recommended line reactor part number for a 15HP 460VAC drive?

Issue:
What is the recommended line reactor part number for a 15HP 460VAC drive?

Product Line:
All

Environment:
All

Cause:
Input or output line/load reactor part numbers.

Resolution:
RL02503 is open style.
RL02513 is enclosed NEMA type 1.
Both are 5% reactors rated for 15HP 480V 3 phase.
This reactor will fit the ATV31HD11N4, ATV61HD11N4 and ATV71HD11N4 or any 15HP 460VAC drive.

What is the plaster bracket to suit the P2025?

The part name is 155P2

What is part number for bracket to suit BSL31VA?

The part number for bracket to suit is 155P.

Will 25/2V double outlet, large size, vertical fit on 155P2 plaster bracket?

Yes, 25/2V will fit on 155P2. 25/2V is  Large Size Format 115 x 115mm, Double Power Outlet rated to 250V 10A.
For further information please visit:
https://www.clipsal.com/Trade/Products/ProductDetail?catno=25/2V
User-added image

155P2 is a large plaster mounting bracket with 84mm mounting centre. For further information please visit:
https://www.clipsal.com/Trade/Products/ProductDetail?catno=155P2
User-added image
 

When is a neutral CT required?

Issue:
When is a neutral CT required?

Product Line:

Environment:

Cause:


Resolution:
A neutral CT is only required when there are loads that produce neutral current.
A neutral CT is required when an electronic-trip circuit breaker has a ground-fault option (alarm or trip) and is used on a 4 wire system. Neutral current must be factored in with phase current for accurate sensing.
A neutral CT is also required for the GFM modules when used on a 4-wire system.


CTA-ID : 1559

What would be the Wall plate (plaster) to suit Prestige large switches?

The wall plate would be the 155P2.

Please go to the website via the following link www.clipsal.com/Trade/Products/ProductDetail  and check under the Documentation Tab for more information.

What is the largest trunking we do in NZ

 The larges is Actassi 155 x 55 part code ISM11400


What is the part number for a PDL DOL Starter 240V 5.5Kw

PDL56DOL12LOBGY - less overload
available on page 155 Pocket book PDL 2014

What does RDY status on an Altivar drive mean?

Issue:
What does RDY status on an Altivar drive mean?
 
Product Line:
All Altivar drives
 
Environment:
All models currently in production, all serial numbers.
 
Cause:
Customer is unsure what this code indicates
 
Resolution:
RDY is an indication that the drive is ready to run and has not detected any faults, but does not currently have a command to run.  This is the normal status of the drive when it is powered, but does not have a run command present, or any other logic inputs triggered to disable the drive, such as a freewheel stop input or external fault input.

Installation Issues with Symmetra LX & 100A Supply

"

Symmetra LX is a redundant on-line double conversion UPS. Each Symmetra Power Module is rated at 4 KVA so when the Symmetra LX is fully populated with 5 power modules, it can draw up to16 KVA from the utility as one power module is redundant. This unit can be used either as a single phase or as a 3 phase unit, without any adjustments or changes being made to system to achieve this.

The Symmetra LX will operate at a voltage of 155 V to 276V , therefore it should draw a current of about 100A at 155V on a full load of 16KVA. Most European regulations require a 35 sq. mm cable for a 100A load but the Symmetra LX connectors will only take a maximum of 25 sq. mm.

However if we look at the power supply in most European countries, the voltage range is 230V - 240V and a voltage of under 200V would be very unusual. Taking a voltage of 240V and running the unit on full load the current would be just over the 65A, with 230V it would still be under 70A and we can drop the down to 200V before reaching 80A. The Symmetra LX should be protected by a slow blow Fuse / MCB which would need a sustained overload of over 1.2 times the rated current for about 2 hours to trip the Fuse / MCB, so even if the voltage drops below 200V the extra current shouldn't cause any problem.

In an area where a reasonably stable voltage exists there is no problem in using 25 sq. mm with an 80A fuse / MCB. Even with substantial voltage drops there is no danger of cables overheating or fuses blowing. In cases where the cable runs are very long and the regulations specify 35 sq. mm cable, the 35 sq. mm cable can be brought to the isolator adjacent to the unit and a 25 sq. mm cable can be used between isolator switch and UPS.

"
Show More