tee solid galv cond 20mm

Series 1246 Machine Cast Fittings, SoLid Tees, 20Mm Galvanised Cast Iron

Catalogue Number: 1246S20
tee solid galv cond 20mm
Colour:
Colour: Per UOM Std.
  • 1 PCE

Specifications

hide show
Product brand
Clipsal
Range of product
Series 1246
Material
cast iron
Surface treatment
galvanised
Diameter
inner: 20 mm
Length
  • 56 mm
  • 88 mm
    • REACh Regulation
      Free of Substances of Very High Concern above the threshold
      REACh free of SVHC
      Yes
      EU RoHS Directive
      Pro-active compliance (Product out of EU RoHS legal scope)
      Toxic heavy metal free
      Yes
      Mercury free
      Yes
      RoHS exemption information
      Yes
      China RoHS Regulation
       Pro-active China RoHS declaration (out of China RoHS legal scope)
      Circularity Profile
      N/A

      Documents & downloads

      hide show
      Filter items
      • All

      • Product Brochures

      • Technical Data Catalogues

      • Installation Instruction

      • Specifications

      • Certificates (MSDS)

      Frequently Asked Questions

      hide show

      What is the part number for a 20mm steel conduit plug?

      The part number  for a 20mm brass plug for steel conduit is 1220S20.

      What is part number for lid to suit 1239/20/4?

      Part number 1239L20 will suit any of 1239/20 series.

      Does the 1240/25 series come with gaskets?

      No, they are light duty. Buy the 1240HL25 to obtain a heavy duty lid and gasket , or if gasket is required for retro fit then buy 1240GT
      For more information on this product range please visit the Clipsal web site on the link provided
      https://www.clipsal.com/Trade/search-results?q=1240

      Whati s pitch thread for part number 1245/25?

      Pitch thread is 1.5mm

      What changes/updates are included in Nxt 2.2 SP8?

      Special 8 Features
      ----------------------------------------------
      - Fixed DDO364-00 User Defined/Last Value settings.
      - Fixed CPS 114-20, CPS 124-20 editing and power ratings.
      - Fixed NOE771-11 card causing an error "File not Found" in the TCOP editor
      - Fixed partial write of state ram clearing logic unintentionally.
      - Removed "Restore PLC Run State Before Power Down" option on the Transfer to Flash dialog for Momentum controllers.


      Legacy KB System (APS) Data: RESL174020 V1.0, Originally authored by on , Last Edited by on
      Related ranges: ProWORX

      Video: How to setup Pulse Width Modulation (PWM) with a SoMachine HMISCU HMI/Controller using SoMachine V4.3

      This video provides a demonstration of the process to configure PWM with SoMachine v4.1.

      How many analog output are available on the Altivar 312 drives?

      Issue:
      How many analog output are available on the Altivar 312 drives? 
       
      Product Line:
      ATV312

      Evironment:
      All

      Cause:
      Application requires 2 analog outputs

      Resolution:
      Only one analog output per drive. No previsions or options for additional input or outputs. 





       

      Does Schneider Electric offer a direct replacement for Berger Lahr motor type IFE71/2CAN-DS/-QBB54/2-064KSP54 with ID number of 66307190016

      No, the Berger Lahr motor type IFE71/2CAN-DS/-QBB54/2-064KSP54 with ID number of 66307190016 is a special version for Atlas Converting in Europe
      There ares some design features incorpoprated in this model which are unique to the OEM Atlas
      This model uses a 64:1 gearbox which is not included in our standard offer.
      The customer must contact the OEM machine builder in Europe for spares.

      rev 11-6-20

      Does the SEPAM MES 114/120 I/O module have analog input availability?

      The Sepam MES114/120 I/O module does not have an input that can monitor the value of an analog signal generated from an external power source. The Sepam I/O modules are designed to detect status changes of a circuit breaker, contactor, plc, etc....., and will output a "0" or "1", depending on the condition of the input signal. The MES114 I/O module (compatible w/ Series 20/40) has up to 10 input connections and the MES120 (compatible w/ Series 80) has up to 14 input connections.
      The Accessory MES114 and MES 120 can be used only in Logical Status

      The MES114 module, on the other hand, will accept analog input signals, but the input APS_SENSORS will only detect whether the status of the analog signal is high "1" or low "0" depending on a certain threshold. These thresholds can be located in the characteristics section of the MES114 install sheet:


      For a 110 V AC analog signal, a signal greater than 88V will force a "1" state and a signal less than 22V will force a "0" state.
      For a 220 V AC analog signal, a signal greater than 176V will force a "1" state and a signal less than 48V will force a "0" state.

      These input status changes can then be used by the Sepam relay to influence control logic, display alarm messages & LEDs, trigger waveforms or open & close relay outputs.

      Nevertheless sepam can use the Accessory MSA 141 to manage an Analogic Output

      AEDL3



       
      Legacy KB System (APS) Data: RESL203471 V1.0, Originally authored by MiZe on 09/21/2010, Last Edited by MiZe on 09/21/2010
      Related ranges: Sepam accessories

      What values should be set for the potential transformer (PT) primary and secondary values in a CM4000 when connecting the voltage inputs of meters directly to the bus (with fuses)?

      Issue
      A user may want to know the PT primary and secondary values for a CM4000 upon initial setup

      Product Line
      CM4000

      Environment
      Setup

      Cause
      The meter may be set to "No PT" or the PT ratio may be used. 

      Resolution
      When setting the PT ratio, one may select "No PT" for the PT Primary Scale - there is no requirement to set the PT ratio if "NO PT" is chosen.

      The PT Primary and PT Secondary inputs are still available, but they are not used when "No PT" is selected for the PT Pri Scale.
      A user would set the PT ratio to "No PT" when the system voltage used by the load to be metered is the same as the system voltage connected directly to the meter (i.e. direct connect with no potential transformers used).

      The PT ratio needs to be set only when the load is using a different voltage from the meter voltage inputs (i.e. potential transformers are being utilized). Potential transformers are used when the voltage of the electrical system is higher than the rated specifications of the meter voltage inputs. The PT primary and secondary ratio on the meter should match that of the potential transformers in the field.

      Example 1: When metering a 1.2 kV system with a set of PT's that contain a ratio of 1200:120, the PT Primary of the meter should be set to 1200 and the PT Secondary of the meter should be set to 120.
      (Potential transformers are used in this scenario because 1.2 kV exceeds the acceptable voltage input threshold the CM4000 can withstand (1–690 L-L, 400 L-N)

      Example 2: When metering a a 480V L-L system, no PT's are being used. The system voltage is directly connected to the metering inputs. In this scenario, you would set the PT Pri Scale of the meter to "No PT".

      Note: If the meter receives voltage that is the same as the voltage used by the load and "No PT" is NOT selected, then a PT ratio of 1:1 would need to be used and is still acceptable. (i.e.This result can be achieved by setting the PT Ratio to 120:120 or 480:480)

      SRT 8 or 10kVA reports Error P.11 or DC Bus Soft Start or event codes 124/125

      Issue: The UPS reports P.11 or DC Bus Soft Start - event 124/125



      Product Line: SRT 8-10kVA Models 

      Resolution:
      Clear the Alarm. Turn the output ON again. If the problem persists, Brain dead the UPS. If the alarm reoccurs, perform a UPS Firmware upgrade to the latest 04.7 revision that addressed these issues. For complete upgrade instructions please refer to FA164737.
       
      Release Notes (UPS 04.7):
      ========================
      1. Improved system performance of transitions between Online and Bypass operation modes.
      2. Improved system behaviour for three phase input configurations to reduce transitions to battery under certain input feed conditions.
      3. Improved system behaviour to eliminate false detection of DC bus under voltage alarm under certain conditions.
      4. Improved system handling for certain AC input conditions during system start-up.