coupling steel con 25mm z/pl

Cable Management Machined Brass, 25Mm Steel Coupling, Zinc Plated

Catalogue Number: 1242S25
coupling steel con 25mm z/pl
Colour:
Colour: Per UOM Std.
  • 1 PCE

Specifications

hide show
Product brand
Clipsal
Material
steel
Surface treatment
zinc plated
Surface finish
polished
Connector type
thread connector
Product destination
diameter: 25-25 mm tube
Length
35.5-35.5 mm
Standards
  • CS 792/S
  • AS 2052
  • AS 1721
    • REACh Regulation
      Free of Substances of Very High Concern above the threshold
      REACh free of SVHC
      Yes
      EU RoHS Directive
      Pro-active compliance (Product out of EU RoHS legal scope)
      Toxic heavy metal free
      Yes
      Mercury free
      Yes
      RoHS exemption information
      Yes
      China RoHS Regulation
       Pro-active China RoHS declaration (out of China RoHS legal scope)
      Circularity Profile
      N/A

      Documents & downloads

      hide show
      Filter items
      • All

      • Product Brochures

      • Technical Data Catalogues

      • Installation Instruction

      • Specifications

      • Certificates (MSDS)

      Frequently Asked Questions

      hide show

      Whati s pitch thread for part number 1245/25?

      Pitch thread is 1.5mm

      Does the 1240/25 series come with gaskets?

      No, they are light duty. Buy the 1240HL25 to obtain a heavy duty lid and gasket , or if gasket is required for retro fit then buy 1240GT
      For more information on this product range please visit the Clipsal web site on the link provided
      https://www.clipsal.com/Trade/search-results?q=1240

      What is the Diameter of the 93B?

      The diameter of the 93B is 91mm.

      Is there 125x125 mini trunking available.

      no, biggest mini trunking size available is 150x75

      What is the part number for a 20mm steel conduit plug?

      The part number  for a 20mm brass plug for steel conduit is 1220S20.

      What load does the 140CRP31200 represent to the 140CPSxxx xx power supply?

      The 140CRP31200 will draw 1.2 amperes from the Quantum's +5 volt bus.






       R-71717

      What is the thread type on a 1235/25?

      The thread type on a 1235/25 is BS - British Standard.

      For more information, please refer to the link:
      https://www.clipsal.com/Trade/Products/ProductDetail?catno=1235/25 

      SRT 8 or 10kVA reports Error P.11 or DC Bus Soft Start or event codes 124/125

      Issue: The UPS reports P.11 or DC Bus Soft Start - event 124/125



      Product Line: SRT 8-10kVA Models 

      Resolution:
      Clear the Alarm. Turn the output ON again. If the problem persists, Brain dead the UPS. If the alarm reoccurs, perform a UPS Firmware upgrade to the latest 04.7 revision that addressed these issues. For complete upgrade instructions please refer to FA164737.
       
      Release Notes (UPS 04.7):
      ========================
      1. Improved system performance of transitions between Online and Bypass operation modes.
      2. Improved system behaviour for three phase input configurations to reduce transitions to battery under certain input feed conditions.
      3. Improved system behaviour to eliminate false detection of DC bus under voltage alarm under certain conditions.
      4. Improved system handling for certain AC input conditions during system start-up.

      What is the dimension of 1260025 TMX-4E hollow wall anchor cavity fixing with screw?

      The dimension of 1260025 TMX-4E is 14mm (diameter) x 47mm (length). 1260025 is cavity fixing including fully threaded screw with combi-head and Phillips cross-slot.
      Benefits
      • Captive fixing – stays fixed even when the screw is not tightened
      • Anti-rotation design
      • Pre-assembled screw
      • High load values
      • Fire-resistant
      • Ideal for overhead cavity fixing
      Material and Operative Data:
      Material cavity fixing Expanding part: electroplated sheet metal
      Screw: electroplated steel
      Material mounting tool: Steel and plastic
      Temperature range:  –40°C to 80°C
      For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=1260025
      User-added image

      Vijeo Designer V6.2 SP4: KAOSCore.DLM is detected incorrectly by Antivirus software as a Trojan virus

      Confirmation from Kaspersky Antivirus has confirmed that Vijeo Designer V6.2 SP4's KAOSCore.dlm is NOT a Trojan virus.

      Please see the note from Kaspersky's support team below:

      Hello,
       
      Sorry, it was a false detection. It will be fixed in the next update.
      Thank you for your help.
       
      Sincerely yours,

      Malware analyst.
      _____________________
      Kaspersky Lab
      Bellevue, USA
       
      39A/3 Leningradskoe Shosse, Moscow, 125212, Russia  Tel./Fax: + 7 (495) 797 8700  https://www.kaspersky.com https://www.viruslist.com
       

      How to create EGX300 custom web pages with multiple devices (two methods: PL Tags and XMLHttpRequest)

      Issue
      There are 2 methods for creating custom web pages for devices on the EGX300.
      1. "PL Tags"
      2. XMLHttpRequest

      Product Line
      EGX300

      Environment
      EGX300 web page
      Text Editor (HTML and JavaScript)
      Modbus Register Maps

      Cause
      When adding devices and register to the web pages, the user will need to use one of the 2 methods. The code will vary depending on the method chosen for the webpage.

      Resolution
      *Warning: Take backups of any files prior to modifying them. Ensure the backups are in a location that will not be overwritten (i.e. the Desktop,etc.).

      method one "PL Tags":
      • These are Server Side Includes (proprietary) that the server uses to read data from device as it serves the page to the host (browser).
      • Can cause the page to load slowly if read request is directed to non-responding device, or if several read requests are made from within the page
      • Requires webpage to be reloaded to update data
      • Easy to use
      Example using PL Tags for two meters
      RegisterSet1 = [PL__3^3209,3210,3211,3208,1180,1100,1103,1104__PL]; //device with unit ID 3
      RegisterSet2 = [PL__5^3209,3210,3211,3208,1180,1100,1103,1104__PL]; //device with unit ID 5

      //device 3
      dev3_ScaleFactorA = RegisterSet1[0]; // Current Scale Factor
      dev3_ScaleFactorB = RegisterSet1[1]; // Neutral Current Scale Factor
      dev3_ScaleFactorC = RegisterSet1[2]; // Ground Current Scale Factor
      dev3_NominalFrequency = RegisterSet1[3];
      dev3_Frequency = RegisterSet1[4];
      dev3_CurrentPhaseA = RegisterSet1[5];
      dev3_CurrentNeutral = RegisterSet1[6];
      dev3_CurrentGround = Registers[7];

      //device 5
      dev5_Frequency = RegisterSet2[4];


      method two XMLHttpRequest:
      • Part of the HTML DOM (Document Object Model), which is a World Wide Web Consortium (W3C) standard
      • Request to read data is made after the page is loaded
      • Data can be updated without reloading the webpage
      • More difficult to implement than PL Tags

      Example using XMLHttpRequest for two meters
      function getData() {
               //device at unit ID 25 and 23 are concatenated in postString
               postString = "PL_" + "_25" + "^3209,3210,3211,3208,1180,1100,1103,1104" + "__PL," +
                                  "PL_" + "_23" + "^1180" + "__PL";
               doRead(xmlhttp, updateData, postString);   
      }

      function updateData(Registers) {
               // Assign Scale Factors
               dev25_ScaleFactorA = Registers[0];  // Current Scale Factor
               dev25_ScaleFactorB = Registers[1];  // Neutral Current Scale Factor
               dev25_ScaleFactorC = Registers[2];  // Ground Current Scale Factor

               // Assign Nominal Frequency
               dev25_NominalFrequency = Registers[3];

               // Assign Data Values
               dev25_Frequency         = Registers[4];
               dev25_CurrentPhaseA  = Registers[5];
               dev25_CurrentNeutral   = Registers[6];
               dev25_CurrentGround   = Registers[7];
              
               //device 23 continues with Register[8] being the first register in the array for this second device
               dev23_Frequency   = Registers[8];

      ...//code continues
      }


      For more details view the PowerLogic Ethernet Gateway EGX300 reference guide 63230-319-230A1
      Also, attached are two example files for the methods mentioned in this article.

      Are EasyPact CVS circuit breakers for sale in the USA or Canada?

      Product Line:
      EasyPact CVS circuit breakers

      Cause:
      This breaker is popular overseas and there is interest in the US

      Resolution:
      There are no plans for a general release of the EasyPact CVS circuit breaker line in North America.

      Will the Compact NSX breaker be for sale in the USA or Canada?

      Issue:
      Where can I buy a Compact NSX breaker?

      Product Line:
      Circuit Breakers

      Cause:
      This breaker is popular overseas and there is interest in the US

      Resolution:
      There are no plans for a general release of the Compact NSX breaker line in North America, since the NSX is not UL Listed to UL489. (UL 489 is the standard commonly required in the US.) In the US, the Powerpact Circuit Breakers should be used (Powerpact breakers are UL, CSA and IEC-rated).

      If an existing piece of equipment has an NSX breaker which needs replacing, we have made a few catalog numbers available for sale in the US. The list of numbers will vary based upon need. Contact your local authorized Schneider Electric distributor for assistance on your specific NSX catalog number.

      For support on these breakers, Please see the following link to Global Operations where you can select other Countries:
      https://www2.schneider-electric.com/sites/corporate/en/support/operations/local-operations/local-operations.page