plug brass screw cond 25mm

Series 1220S Brass Plugs, 25mm, Screwed Conduit, Brass Plug

Catalogue Number: 1220S25
plug brass screw cond 25mm
Retail
$47.40
RRP (Inc. GST)

Specifications

hide show
Product brand
Clipsal
Range of product
Series 1220S
Material
brass
Product destination
diameter: 25-25 mm tube
Stub stiffness
rigid
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Weight
36 g
Package 1 Height
12 mm
Package 1 width
25 mm
Package 1 Length
25 mm
Unit Type of Package 2
BB1
Number of Units in Package 2
20
Package 2 Weight
0.78 kg
Package 2 Height
60 mm
Package 2 width
78 mm
Package 2 Length
78 mm
Unit Type of Package 3
CAR
Number of Units in Package 3
240
Package 3 Weight
8.9 kg
Package 3 Height
175 mm
Package 3 width
160 mm
Package 3 Length
240 mm
REACh free of SVHC
Yes
EU RoHS Directive
Pro-active compliance (Product out of EU RoHS legal scope)
Toxic heavy metal free
Yes
Mercury free
Yes
RoHS exemption information
Yes
China RoHS Regulation
 Pro-active China RoHS declaration (out of China RoHS legal scope)

Frequently Asked Questions

hide show

What is the part number for a 20mm steel conduit plug?

The part number  for a 20mm brass plug for steel conduit is 1220S20.

Does the 1240/25 series come with gaskets?

No, they are light duty. Buy the 1240HL25 to obtain a heavy duty lid and gasket , or if gasket is required for retro fit then buy 1240GT
For more information on this product range please visit the Clipsal web site on the link provided
https://www.clipsal.com/Trade/search-results?q=1240

Is there a black version of the 220S20?

Yes, there is.  The 220S20 comes in 3 colors.

For more information, please refer to the link:
https://www.clipsal.com/Trade/Products/ProductDetail?catno=220S20 

What is the dimension of 1260025 TMX-4E hollow wall anchor cavity fixing with screw?

The dimension of 1260025 TMX-4E is 14mm (diameter) x 47mm (length). 1260025 is cavity fixing including fully threaded screw with combi-head and Phillips cross-slot.
Benefits
• Captive fixing – stays fixed even when the screw is not tightened
• Anti-rotation design
• Pre-assembled screw
• High load values
• Fire-resistant
• Ideal for overhead cavity fixing
Material and Operative Data:
Material cavity fixing Expanding part: electroplated sheet metal
Screw: electroplated steel
Material mounting tool: Steel and plastic
Temperature range:  –40°C to 80°C
For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=1260025
User-added image

Is there 125x125 mini trunking available.

no, biggest mini trunking size available is 150x75

Whati s pitch thread for part number 1245/25?

Pitch thread is 1.5mm

What is the thread type on a 1235/25?

The thread type on a 1235/25 is BS - British Standard.

For more information, please refer to the link:
https://www.clipsal.com/Trade/Products/ProductDetail?catno=1235/25 

Momentum CAD Drawings

Goals and Symptoms

Momentum CAD Drawings

Causes and Fixes

Momentum CAD Drawings as of 1/20/05

The Micrologic Trip Unit screen displays the message "Comms not available" when trying to set Com Parameters.

Issue:
When trying to set up communications parameters on the Micrologic trip unit, the message on the trip unit screen shows "Comms not available".

Product Line:
Circuit Breakers

Environment:
Applies to Micrologic Trip Unit models 3.0A, 5.0A, 5.0P, 5.0H, 6.0A, 6.0P, 6.0H

Cause:
For some reason, the communication parameters cannot be set up in the Micrologic Trip Unit.

Resolution:
When setting up the Com Parameters using the Micrologic Trip Unit screen, if the trip unit screen displays the message "Comms not available", it may be caused by one of the following:
-The BCM is not installed (Breaker Communications Module)
-The BCM is not powered (it requires 24Vd on terminals E1+ and E2-)
-The polarity of the 24Vdc power supply is reversed (it should be positive on E1, negative on E2)
-The BCM is damaged
-The BCM and the Trip Unit communicate through an optical port. Check for foreign material blocking the optical port.
If the above check OK, then contact us for technical support.

STBNIP2212 Advantys Non-RoHs Ethernet NIM Firmware Upgrade - Exec v.2.31, Kernel 2.04, Web 1.20.05

Release Notice

The purpose of this resolution is to inform STBNIP2212 users that the Exec., Kernel, and Web pages have been upgraded to the following:

    • Exec v.2.31
    • Kernel v. 2.04
    • Web page v.1.20.05

Goals and Symptoms

Exec file, nip2212_upgrade_[k]_v2.04.06_[fw]_v2.31.09_[web]_v1.20.05.exe, is now available and will automatically run the loader utility program when executed and prompt the user to enter the IP address of the Ethenet NIM. The Exec, Kernel, and web files will load sequentially and then reboot the NIM when completed.

Facts and Changes

The new Exec., Kernel and web versions are field upgradable and will work with any STBNIP2212 Ethernet NIM hardware whose firmware is version 2.30 or less. This Exec cannot be loaded into NIMs that have an SV 2.70 or higher.

  • STBNIP2212's whose Exec versions are 2.3x or less are non-RoHs units. STBNIP2212's whose Exec versions are 2.7x or higher are RoHs units. The Execs between these units are not interchangeable.
    • RoHs is the acronym for Restriction of Hazardous Substances. RoHS, also known as Directive 2002/95/EC, originated in the European Union and restricts the use of specific hazardous materials found in electrical and electronic PRODUCTS. The substances banned under RoHS are lead (Pb), mercury (Hg), cadmium (Cd), hexavalent chromium (CrVI), polybrominated biphenyls (PBB) and polybrominated diphenyl ethers (PBDE).
  • Firmware for the RoHs and Non-RoHs Ethernet NIMs is available on Planet.

Causes and Fixes

The following issues have been resolved in this version:

  1. The STBNIP2212 may go into fallback in the presence of UDP traffic.
  2. Error '1013h' may occur when attempting to connect to the Ethernet NIM using Advantys Config Software.
  3. STBNIP2212 Broadcast Filter improvements implemented.
  4. An error would occur when an Island configuration file from an FDR server was loaded into an STBNIP2212 after a power cycle of the NIM or the Restore function in the FDR Configuration web page was initiated. This resulted in the error, 'FDR parameter file from the server is invalid' in the 'Error Log' web page.
  5. Power cycling a large island with mandatory modules does not always start in RUN.
  6. STBNIP2212 v.2.30 NIMs could randomly go to 'fallback' and require a power cycle to recover.

Legacy KB System (APS) Data: RESL199672 V1.0, Originally authored by DaDz on 08/21/2009, Last Edited by DaDz on 08/21/2009
Related ranges: Advantys STB

STBNIP2212 Advantys RoHs Ethernet NIM Firmware Upgrade - Exec v.2.71, Kernel 2.21, Web 1.20.05

Release Notice

The purpose of this resolution is to inform STBNIP2212 users that the Exec., Kernel, and Web pages have been upgraded to the following:

    • Exec v.2.71
    • Kernel v. 2.21
    • Web page v.1.20.05

Goals and Symptoms

Exec file, nip2212_upgrade_[k]_v2.21.02_[fw]_v2.71.02_[web]_v1.20.05.exe, is now available and will automatically run the loader utility program when executed and prompt the user to enter the IP address of the Ethenet NIM. The Exec, Kernel, and web files will load sequentially and then reboot the NIM when completed.

Facts and Changes

The new Exec., Kernel and web versions are field upgradable and will work with any STBNIP2212 Ethernet NIM hardware whose firmware is version 2.70 or higher. This Exec cannot be loaded into NIMs that have an SV 2.30 or lower.

  • STBNIP2212's whose Exec versions are 2.3x or less are non-RoHs units. STBNIP2212's whose Exec versions are 2.7x or higher are RoHs units. The Execs between these units are not interchangeable.
    • RoHs is the acronym for Restriction of Hazardous Substances. RoHS, also known as Directive 2002/95/EC, originated in the European Union and restricts the use of specific hazardous materials found in electrical and electronic PRODUCTS. The substances banned under RoHS are lead (Pb), mercury (Hg), cadmium (Cd), hexavalent chromium (CrVI), polybrominated biphenyls (PBB) and polybrominated diphenyl ethers (PBDE).
  • Firmware for the RoHs and Non-RoHs Ethernet NIMs is available on Planet.

Causes and Fixes

The following issues have been resolved in this version:

  1. The STBNIP2212 may go into fallback in the presence of UDP traffic.
  2. Error '1013h' may occur when attempting to connect to the Ethernet NIM using Advantys Config Software.
  3. STBNIP2212 Broadcast Filter improvements were implemented.
  4. An error would occur when an Island configuration file from an FDR server was loaded into an STBNIP2212 after a power cycle of the NIM or the Restore function in the FDR Configuration web page was initiated. This resulted in the error, 'FDR parameter file from the server is invalid' in the 'Error Log' web page.
  5. Power cycling a large island with mandatory modules does not always start in RUN.
  6. STBNIP2212 v2.70 NIMs could randomly go to 'fallback' and require a power cycle to recover.

Legacy KB System (APS) Data: RESL199680 V1.0, Originally authored by DaDz on 08/21/2009, Last Edited by DaDz on 08/21/2009
Related ranges: Advantys STB

SRT 8 or 10kVA reports Error P.11 or DC Bus Soft Start or event codes 124/125

Issue: The UPS reports P.11 or DC Bus Soft Start - event 124/125



Product Line: SRT 8-10kVA Models 

Resolution:
Clear the Alarm. Turn the output ON again. If the problem persists, Brain dead the UPS. If the alarm reoccurs, perform a UPS Firmware upgrade to the latest 04.7 revision that addressed these issues. For complete upgrade instructions please refer to FA164737.
 
Release Notes (UPS 04.7):
========================
1. Improved system performance of transitions between Online and Bypass operation modes.
2. Improved system behaviour for three phase input configurations to reduce transitions to battery under certain input feed conditions.
3. Improved system behaviour to eliminate false detection of DC bus under voltage alarm under certain conditions.
4. Improved system handling for certain AC input conditions during system start-up.
Show More