Canalis KBB Straight length 40A, 2 circuits L+N+PE, 3 tap-off units, 2m

Canalis KBB Straight length 40A, 2 circuits L+N+PE, 3 tap-off units, 2m

Item Number: KBB40ED22203

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range

Canalis

Range of product

Canalis

Product compatibility

KBB

Product or component type

busbar trunking

Device application

  • power socket distribution
  • lighting

Warranty

18 months

Physical

[ie] rated operational current

40 A at 35 °C

[ue] rated operational voltage

230...400 V

Control type

without

Mounting mode

by screws

Standards

  • EN/IEC 61439-6
  • EN/IEC 61439-1

Width

30 mm

Height

46 mm

Length

2 m

Net weight

3.6 kg

Ip degree of protection

IP55 conforming to EN/IEC 60529

Ik degree of protection

IK06 conforming to EN/IEC 62262

Ambient air temperature for operation

  • 0...35 °C (100 % of In)
  • 35...40 °C (96 % of In)
  • 40...45 °C (93 % of In)
  • 45...50 °C (89 % of In)
  • 50...55 °C (85 % of In)

Environmental disclosure

ENVPEP061102EN

Eu rohs directive

Pro-active compliance (Product out of EU RoHS legal scope)

Others

Legacy weee scope

In

At least in Europe

Weee label

The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

Device short name

KBB

Busbar description

straight length

Network frequency

50/60 Hz

Busbar trunking polarity

L + N + PE

Number of circuits

2

Number of tap-off outlets

3

[uimp] rated impulse withstand voltage

4 kV

[ui] rated insulation voltage

690 V

[icw] rated short-time withstand current

0.94 kA

[ipk] rated peak withstand current

9.6 kA

Thermal stress limit

900 kA².s

Maximum radiated magnetic field

2 pT

Thdi

  • 0...15 % 40 A
  • 15...33 % 32 A
  • 33...100 % 28 A

Maximum voltage drop

  • <0.3 V with power factor = 1 at 50 Hz with 1A for 100 m long
  • <0.28 V with power factor = 0.9 at 50 Hz with 1A for 100 m long
  • <0.25 V with power factor = 0.8 at 50 Hz with 1A for 100 m long
  • <0.22 V with power factor = 0.7 at 50 Hz with 1A for 100 m long

Linear resistance

  • 0.02 mΩ/m X1 35 °C at Inc and 50 Hz phase conductor
  • 0.8 mΩ/m protective conductor
  • 2.83 mΩ/m R20 20 °C phase conductor
  • 3.46 mΩ/m R1 35 °C at Inc and 50 Hz phase conductor
  • 3.46 mΩ/m Z1 35 °C at Inc and 50 Hz phase conductor
  • 13.83 mΩ/m R0 20 °C symmetrical components method Ph/PE
  • 0.73 mΩ/m X0 20 °C symmetrical components method Ph/PE
  • 13.85 mΩ/m Z0 20 °C symmetrical components method Ph/PE
  • 5.68 mΩ/m Rb0 20 °C impedance method Ph/Ph
  • 5.68 mΩ/m Rb0 20 °C impedance method Ph/N
  • 0.9 mΩ/m Xb 35 °C at Inc and 50 Hz with impedance method Ph/Ph
  • 0.9 mΩ/m Xb 35 °C at Inc and 50 Hz with impedance method Ph/N
  • 17.28 mΩ/m R0 20 °C symmetrical components method Ph/N
  • 5.25 mΩ/m X0 20 °C symmetrical components method Ph/N
  • 18.06 mΩ/m Z0 20 °C symmetrical components method Ph/N
  • 6.92 mΩ/m Rb0 20 °C impedance method Ph/PE
  • 6.92 mΩ/m Rb1 35 °C at Inc with impedance method Ph/Ph
  • 6.92 mΩ/m Rb1 35 °C at Inc with impedance method Ph/N
  • 7.14 mΩ/m Rb1 35 °C at Inc with impedance method Ph/PE
  • 1.85 mΩ/m Xb 35 °C at Inc and 50 Hz with impedance method Ph/PE

Unit type of package 1

PCE

Number of units in package 1

1

Sustainable packaging

No

Weee label

The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
Show all specifications

Documents & downloads

hide show
Filter items
  • All

  • Product Brochures

  • Technical Data Catalogues

  • Environmental Disclosure

  • Installation Instruction

  • Specification Guide

  • Certificates (MSDS)

  • Declaration of Conformity (Sustainability)

Important: Some software files may need a mySchneider or Club login to download.