755PFM4 is a photoelectric flush mount smoke alarm that can be used as a single mains powered battery backed alarm or can be interconnected with other 755 series smoke alarms. The stylish design is extremely low profile and unobtrusive. It caters for fast installs with 90mm cut out & extra large terminals.

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Free Introductory Training Module

On installation, maintenance and troubleshooting

Home owner checking their fire alarm
Clipsal Firetek group shot of products and packaging
dimensions

Specifications

Design

Range Fire Tek
Product brand Clipsal
Product or component type smoke detector
Device application early detection of smouldering fires and open fires

Physical

Type of packing carton
Supply mains
[in] rated current
  • 13 µA at 9 V, DC not in operation
  • 40 mA at 9 V, DC operation
Function available
  • local alarm
  • hush function
  • self-test of smoke detection
Control type button (test/hush function)
Local signalling
  • sound: signal
  • visual: LED (red) for warning and low battery
  • visual: LED (green) for ON status
Connections - terminals
  • screw terminal (line) - 2 x 1...3 x 2.5 mm²
  • screw terminal (neutral) - 2 x 1...3 x 2.5 mm²
  • screw terminal (earth loop) - 2 x 1...3 x 2.5 mm²
  • screw terminal (interconnect) - 2 x 1...3 x 2.5 mm²
Type of installation indoor
Device mounting flush
Mounting support ceiling
Fixing mode by screws
Depth 102.6 mm
Net weight 263 g
Ip degree of protection IP20
Ambient air temperature for operation 0...45 °C
Ambient air temperature for storage -20...60 °C
Relative humidity 5...95 %
Product certifications
  • RCM
  • SAI
  • Activfire
Standards
  • ISO 8201
  • AS 3786:2014
  • AS/NZS 60950.1
  • AS/NZS 60065
Mercury free Yes
Rohs exemption information Yes
Environmental disclosure ENVPEP1907002_V1
Reach regulation Reference contains Substances of Very High Concern above the threshold
China rohs regulation X
Eu rohs directive Compliant By Exemption

Material

Device composition
  • 1 mounting base
  • 1 dust protection foil
  • 1 user guide
  • 3 screws
  • 1 sticker sheet
Material thermoplastic

Others

Legacy weee scope In
Outside of Europe
Average percentage of recycled plastic content 0 %
Package 1 bare product quantity 1
Warranty duration(in months) bmecat 18
Weee label N/A
Weee applicability Finished product
Electronic sensor type photo-electric sensor
[us] rated supply voltage 220...240 V AC 50 Hz
Battery type alkaline 9 V 6LR61
Battery life 1 year(s)
Output voltage limits interconnection: 6.5...20 V
Type of alarms low battery at 6.9...7.5 V
Detection type heat
Technology type scattered light (Tyndall effect)
Type of measurement optic
Number of devices 40 for wired alarm wired over <= 150 m
Noise level 85 dB at 3 m, minimum
Diameter 108 mm
Projecting depth 23 mm
Unit type of package 1 PCE
Number of units in package 1 1
Package 1 height 10.6 cm
Package 1 width 14.5 cm
Package 1 length 14.5 cm
Package 1 weight 343 g
Green premium status for reporting Green Premium product
Total lifecycle carbon footprint 0 kg CO2 eq.
Carbon footprint of the manufacturing phase [a1 to a3] 0.0029770289230769227
Carbon footprint of the manufacturing phase [a1 to a3] 0 kg CO2 eq.
Carbon footprint of the distribution phase [a4] 0.00004425579487179486
Carbon footprint of the distribution phase [a4] 0 kg CO2 eq.
Carbon footprint of the installation phase [a5] 0.00001034945333333333
Carbon footprint of the installation phase [a5] 0 kg CO2 eq.
Carbon footprint of the use phase [b2, b3, b4, b6] 0
Carbon footprint of the use phase [b2, b3, b4, b6] 0 kg CO2 eq.
Sustainable packaging No
Carbon footprint of the end-of-life phase [c1 to c4] 0.00009301808205128207
Carbon footprint of the end-of-life phase [c1 to c4] 0 kg CO2 eq.
Pvc free Yes
Halogen-free status Halogen free product
Take-back No
Product contributes to saved and avoided emissions No
Removable battery N/A
Total lifecycle carbon footprint 0.0031246522533333334
Average percentage of recycled metal content 0 %
Packaging made with recycled cardboard No
Packaging without single use plastic No
China rohs label 3
Halogen-free status Halogen free product
Pvc free Yes
End of life manual availability ENVEOLI1907002EN
Take-back No
Warranty (in months) 18

Documents & downloads

Filter items
  • All

  • Product Brochures

  • Other technical guide

  • Installation Instruction

  • End of Life Manual

  • Environmental Disclosure

  • Operating Manuals

  • Certificates (MSDS)

  • Declaration of Conformity (Sustainability)

Important: Some software files may need a mySchneider or Club login to download.

Frequently Asked Questions

What causes the smoke alarm to continuously beep ?

Hide Show
The dust inside the smoke alarms can cause a continuous beep.
Please follow the regular maintenance check to avoid this.

Vacuum the smoke alarms using a soft brush attachment-
Keeping your smoke alarm free of dust particles, dirt, kitchen grease or cobwebs will help you reduce false alarms and ensure any smoke can easily reach the internal sensing chamber.

Clean and wipe down around unit-
Clean around the smoke alarm unit and remove any insects or other contamination which may have occurred. Spray bug repellent on a cloth and wipe the ceiling around the smoke alarm to act as a future bug deterrent. Clean every 3-6 months to mitigate insect ingress.

ALWAYS TEST THE SMOKE ALARM AFTER CLEANING.

Attached is the Clipsal smoke alarm troubleshooting guide for more info.

SMOKE ALARM
 

What is the warranty period for the 755 series smoke alarms?

Hide Show
The 755 series smoke alarms have a 5 year warranty period
 
Firetek group shot

Range

Clipsal's Fire Tek range helps protect the most valuable assets; family, friends and the home.

They are backed by the SAI Global 5 ticks certification of quality, offering robust designs for reliability, ensuring early detection and warning from hazardous smoke and fire.

The Australian Building Code mandates all new homes must have AS3786:2014 compliant smoke alarms installed, interconnected and hard wired to mains power.

By having Fire Tek's smoke alarms installed, you will have the best chance of escaping the devastating effects of a house fire.

Visit our Smoke Alarms FAQ page

To learn more