TeSys GV4, Voltage release, TeSys GV4, MX coil, 380 to 415VAC 50Hz, 440 to 480VAC 60Hz

Home ProductsIndustrialTeSysVoltage release, TeSys GV4, MX coil, 380 to 415VAC 50Hz, 440 to 480VAC 60Hz

TeSys GV4, Voltage release, TeSys GV4, MX coil, 380 to 415VAC 50Hz, 440 to 480VAC 60Hz

Item Number: GV4AS487

TeSys GV electrical trip unit, MX shunt trip, 380-415V AC 50Hz / 440-480V AC 60Hz, for motor circuit breakers GV4. It trips the circuit breaker when the control voltage is applied in limits 0.7-1.1 Uc with an impulse duration greater than 20ms or a maintained signal. To be plugged inside the circuit breaker, connection by spring terminals. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range

TeSys

Product or component type

voltage release

Device application

control

Physical

Range compatibility

TeSys TeSys GV4|TeSys TeSys BV4

Mounting mode

internal mounting

Mechanical durability

20000 cycles

Connections - terminals

spring terminals 1 0.5-1.5 mm² - cable stiffness: flexible without cable end

Wire stripping length

8 mm

Quantity per set

set of 1

Eu rohs directive

Compliant with Exemptions

Mercury free

Yes

Rohs exemption information

Yes

China rohs regulation

Product out of China RoHS scope. Substance declaration for your information

Environmental disclosure

ENVPEP2311043EN

Circularity profile

ENVEOLI2311043EN

California proposition 65

WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

Others

Life cycle assessment data

Yes

Substance regulation data deliverable

Yes

Package 1 bare product quantity

1

Device short name

MX

Voltage release type

shunt trip release

[uc] control circuit voltage

440...480 V AC 60 Hz|380...415 V AC 50 Hz

[ui] rated insulation voltage

480 V conforming to IEC 60947-1

Threshold tripping voltage

0.7...1.1 Un failsafe opening|< 0.7 Un possible opening

Impulse duration

>= 20 ms

Maximum inrush power in va

6 VA

Maximum hold-in power consumption in va

10 VA

Operating time

< 50 ms

Unit type of package 1

PCE

Number of units in package 1

1

Package 1 height

3.5 cm

Package 1 width

6.0 cm

Package 1 length

8.0 cm

Package 1 weight

64.0 g

Unit type of package 2

BB1

Number of units in package 2

10

Package 2 height

9.0 cm

Package 2 width

13.0 cm

Package 2 length

18.5 cm

Package 2 weight

680.0 g

Unit type of package 3

S03

Number of units in package 3

120

Package 3 height

30.0 cm

Package 3 width

30.0 cm

Package 3 length

40.0 cm

Package 3 weight

8.601 kg

Weee

The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
Show all specifications

Documents & downloads

hide show
Filter items
  • All

  • CAD Files and Packs

  • Technical Data Catalogues

  • End of Life Manual

  • Environmental Disclosure

  • Installation Instruction

  • Operating Manuals

  • Certificates (MSDS)

  • Declaration of Conformity