Zelio Logic Modem Interface, GSM, for Communication Interface SR2COM02

Zelio Logic Modem Interface, GSM, for Communication Interface SR2COM02

Zelio Logic Modem Interface, GSM, for Communication Interface SR2COM02

Item Number: SR2MOD02

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Warranty

18 months

Range of product

Zelio Logic

Product or component type

GSM modem

Physical

Function available

  • send alarm/receive instruction
  • send alarm to e-mail address
  • transfer program
  • update firmware monitoring

Connections - terminals

  • screw terminals, 1 x 0.25...1 x 2.5 mm² (AWG 24...AWG 14) flexible with cable end
  • screw terminals, 2 x 0.25...2 x 0.75 mm² (AWG 24...AWG 18) flexible with cable end
  • screw terminals, 1 x 0.25...1 x 2.5 mm² (AWG 24...AWG 14) semi-solid
  • screw terminals, 1 x 0.25...1 x 2.5 mm² (AWG 24...AWG 14) solid
  • screw terminals, 2 x 0.25...2 x 1.5 mm² (AWG 23...AWG 16) solid

Net weight

0.335 kg

Product certifications

  • UL
  • PTCRB
  • GOST
  • CSA
  • IC
  • FCC part 15 standard
  • C-Tick

Standards

  • EN/IEC 60068-2-6 Fc
  • EN/IEC 60068-2-32

IP degree of protection

IP31 conforming to IEC 60529

Environmental characteristic

  • low voltage directive conforming to EN/IEC 60950-1
  • R and TTE directive conforming to ETSI EN 301419-1
  • R and TTE directive conforming to ETSI EN 301 489-7
  • R and TTE directive conforming to ETSI EN 301 511
  • EMC directive conforming to ETSI EN 301 489-1

Ambient air temperature for operation

  • -20...55 °C conforming to IEC 60068...2-1
  • -20...55 °C conforming to IEC 60068...2-2

Ambient air temperature for storage

-40...70 °C

Relative humidity

  • 0...95 % at 55 °C without condensation
  • 0...95 % without condensation, during storage

REACh Regulation

Reference contains Substances of Very High Concern above the threshold

EU RoHS Directive

Pro-active compliance (Product out of EU RoHS legal scope)

Mercury free

Yes

RoHS exemption information

Yes

China RoHS Regulation

X

California proposition 65

WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

Others

Kit composition

  • GSM modem
  • fixing on DIN rail (assembled with the GSM modem)
  • 1 supply cable
  • 1 antenna with cable
  • 2 lugs for plate mounting

Number of messages

28

Electrical data recording

  • telephone/e-mail
  • discrete and digital value
  • date and time

[Us] rated supply voltage

12...24 V DC

Supply voltage limits

5.5...32 V

Maximum supply current

  • 165 mA at 12 V
  • 87 A at 24 V
  • 2100 mA at 5.5 V

Power dissipation in W

2.1 W

Associated fuse rating

2.5 A

Electrical connection

  • 1 cable Com-M Com-M specific to Zelio RS232 serial, specific Zelio communication protocol for link with the modem, AT commands
  • 1 antenna with cable
  • 1 cable
  • 1 cable Com-Z Com-Z specific to Zelio, specific Zelio communication protocol for Zelio Logic smart relays SR.B..... and SR2 E..... Version (>= V3.1)
  • supply cable

Cable length

  • 1.5 m supply cable
  • 2.5 m antenna with cable

Insulation

  • 1780 V optocoupler, connector type: Com-Z specific to Zelio
  • by the cable SR2 CBL07, connector type: Com-M specific to Zelio

Tightening torque

0.5 N.m

Electromagnetic compatibility

conducted and radiated emissions class B group 1 conforming to EN 55022-11

Pollution degree

2 conforming to EN/IEC 61131-2

Operating altitude

2000 m

Maximum altitude transport

3048 m

Unit Type of Package 1

PCE

Number of Units in Package 1

1

Package 1 Weight

318.0 g

Package 1 Height

7.5 cm

Package 1 width

7.5 cm

Package 1 Length

14.7 cm

Unit Type of Package 2

S03

Number of Units in Package 2

20

Package 2 Weight

6.895 kg

Package 2 Height

30 cm

Package 2 width

30 cm

Package 2 Length

40 cm

PVC free

Yes

Type of modem

type quad band 900/1800 MHz, 850/1900 MHz

Data backed up

flash memory
Show all specifications

Documents & downloads

hide show
Filter items
  • All

  • Product Brochures

  • Technical Data Catalogues

  • Installation Instruction

  • Operating Manuals

  • eTechPub

  • Declaration of Conformity

  • Certificates (MSDS)

Frequently Asked Questions

hide show

What is required to setup SMS messaging in ClearSCADA?

Using a GSM Modem attached to your ClearSCADA Server doesn't require any third party software and the communication can be two way. You can send SMS messages out of ClearSCADA and you can also receive SMS Messages into ClearSCADA. 

Recommended Hardware: Schneider Modem SR2 MOD02
Note: Not all GSM Modems work
 
I altered the ClearSCADA pager communications channel settings as follows to match the modems defaults. The paperwork that came with the modem didn't give me this vital information. So I found this information in SR2MOD02 and SR2MOD03 Wireless Modem User Guide 11/2013 on page 45 of a manual that I downloaded. 
        Baud Rate         = 115200 
        Data Bits        = 7 
        Parity                = Even 
        Stop Bits         = 1 
        Flow Control        = RTS/CTS 
 
To send and receive SMS Messages you need to use the Pager Driver in ClearSCADA. 
 
The online help gives some good information regarding this and can be found here 
 
Driver Reference -> Pager Driver 
 
The object you would need to create in ClearSCADA to send a SMS include 
Pager -> SMS Pager Channel 
Pager -> SMS Service 
Alarm that would trigger the SMS 
Alarm Redirection configured on the Alarm object or Group Object 
Alarm Redirection -> Pager Action 
User or Group of users in the database to send the redirection complete with contact details don't forget the +61 for the phone number and drop the 0 at the start of a mobile number. 
 
The additional object you would need to create in ClearSCADA to process an inbound SMS include 
Other -> Method call 
 
Lots of other things can be done with Calendar and roster objects also...... 
 
For product support the following email is best. 
scada.support@schneider-electric.com