Quantcast

Compact NSX Circuit Breaker, TMD, 80A, 3 Poles 3d

Compact NSX Circuit Breaker, TMD, 80A, 3 Poles 3d

Compact NSX Circuit Breaker, TMD, 80A, 3 Poles 3d

Item Number: LV429631

Retail
N/A
RRP (Inc. GST)

Product Dimensions

Width icon

Width105 mm

Height icon

Height161 mm

Depth icon

Depth86 mm

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Sustainable offer status

Green Premium product

Warranty

18 months

Range

ComPact

Range of product

ComPact NSX100...250

Product or component type

circuit breaker

Device application

distribution

Physical

Mechanical durability

50000 cycles

Electrical durability

  • 10000 cycles at 690 V In
  • 20000 cycles at 690 V In/2
  • 30000 cycles at 440 V In
  • 50000 cycles at 440 V In/2
    • Mounting support

      backplate

      Protection type

    • L : for overload protection (thermal)
    • I : for short-circuit protection (magnetic)
      • Width

        105 mm

        Height

        161 mm

        Depth

        86 mm

        Net weight

        2.05 kg

        Standards

        EN/IEC 60947

        Product certifications

      • CCC
      • EAC
      • Marine
        • IP degree of protection

          IP40 conforming to IEC 60529

          IK degree of protection

          IK07 conforming to IEC 62262

          Ambient air temperature for operation

          -25-70 °C

          Ambient air temperature for storage

          -50-85 °C

          Relative humidity

          0-95 %

          REACh Regulation

          Free of Substances of Very High Concern above the threshold

          EU RoHS Directive

          Compliant

          Mercury free

          Yes

          RoHS exemption information

          Yes

          China RoHS Regulation

          Product out of China RoHS scope. Substance declaration for your information

          Environmental Disclosure

          ENVPEP120606EN

          Circularity Profile

          ENVEOLI120604EN

          California proposition 65

          WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

          [In] rated current

          80 A at 40 °C

          [Ue] rated operational voltage

          690 V AC 50/60 Hz

          Control type

          toggle

          Mounting mode

          fixed

          Others

          [Ui] rated insulation voltage

          800 V AC 50/60 Hz

          [Uimp] rated impulse withstand voltage

          8 kV

          [Ics] rated service breaking capacity

        • 11 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2
        • 35 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
        • 36 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
        • 4 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
        • 85 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
        • 12.5 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
          • Upside connection

            front

            Downside connection

            front

            Connection pitch

            35 mm

            Trip unit rating

            80-80 A at 40 °C

            Long time pick-up adjustment type Ir

            adjustable

            Long time pick-up adjustment range

            0.7...1 x In

            Long time delay adjustment type

            fixed

            [tr] long-time delay adjustment range

          • 120-400 s at 1.5 x In
          • 15-15 s at 6 x Ir
            • Short-time pick-up adjustment type Isd

              fixed

              [Isd] short-time pick-up adjustment range

              640 A

              Short-time delay adjustment type

              fixed

              Earth-leakage protection

              without

              Number of slots

              5 slot(s)

              Compatibility code

              NSX100

              Overvoltage category

              class II

              Electrical shock protection class

              class II

              Pollution degree

              3 conforming to IEC 60664-1

              Operating altitude

            • 0...2000 m without derating
            • 2000 m...5000 m with derating
              • Unit Type of Package 1

                PCE

                Number of Units in Package 1

                1

                Package 1 Weight

                1.773 kg

                Package 1 Height

                14 cm

                Package 1 width

                11.5 cm

                Package 1 Length

                19 cm

                Unit Type of Package 2

                S04

                Number of Units in Package 2

                12

                Package 2 Weight

                22.042 kg

                Package 2 Height

                30 cm

                Package 2 width

                40 cm

                Package 2 Length

                60 cm

                WEEE

                The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

                Product name

                ComPact NSX

                Device short name

                NSX100F

                Poles description

                3P

                Protected poles description

                3t

                Network type

                AC

                Network frequency

                50/60 Hz

                Suitability for isolation

                yes conforming to EN/IEC 60947-2

                Utilisation category

                category A

                Breaking capacity

              • 10 kA at 600 V AC 50/60 Hz conforming to UL 508
              • 25 kA at 480 V AC 50/60 Hz conforming to UL 508
              • 85 kA at 240 V AC 50/60 Hz conforming to UL 508
              • 22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
              • 25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
              • 35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
              • 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
              • 8 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
              • 85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
                • Breaking capacity code

                  F 36 kA 415 V AC

                  Trip unit name

                  TM-D

                  Trip unit technology

                  thermal-magnetic

                  Trip unit protection functions

                  LI
                  Show all specifications

                  Documents & downloads

                  hide show
                  Filter items
                  • All

                  • CAD Files and Packs

                  • Product Brochures

                  • Technical Data Catalogues

                  • Installation Instruction

                  • Operating Manuals

                  • Technical Drawing

                  • Marine Certificate

                  Frequently Asked Questions

                  hide show

                  What is the replacement model for a NS100N 3 Pole molded case circuit breaker?

                  The replacement model for a NS100N 3 Pole is the NSX100F 3P range.

                  NSX100F: (36kA at 415V)
                  Complete/3 Pole Front Connected
                  DescriptionTypeTrip UnitRatingPart Number
                  NSX100F (36kA) Distribution ProtectionStandard thermal-magnetic trip unit TM-DTM16D11-16ALV429637
                  TM25D17-25ALV429636
                  TM32D22-32ALV429635
                  TM40D28-40ALV429634
                  TM50D35-50ALV429633
                  TM63D44-63ALV429632
                  TM80D56-80ALV429631
                  TM100D70-100ALV429630
                  Electronic Trip unit Micrologic 2.2 (LSol)40A18-40ALV429772
                  100A40-100LV429770
                  Electronic Trip unit Micrologic 5.2A (LSI) (ammeter)40A18-40ALV429882
                  100A40-100LV429880
                  NSX100F (36kA)
                  Motor Protection
                  Nagnetic only trip Unit MAMA2.52.5A, 0.75kWLV429745
                  MA6.36.3A, 2.2kWLV429744
                  MA12.512.5A, 5.5kWLV429743
                  MA2525A, 11kWLV429742
                  MA5050A, 22kWLV429741
                  MA100100A, 45kWLV429740
                  Electronic Trip unit Micrologic 2.2 (LSol)25A12-25A, 11kWLV429828
                  50A25-50A, 22kWLV429827
                  100A50- 100A, 45kWLV429825



                  There is also a 4P model as well.

                  Please see link to Product guide - https://www2.schneider-electric.com/resources/sites/SCHNEIDER_ELECTRIC/content/live/FAQS/297000/FA297893/pl_PL/CROSSFER%20NS%20TO%20NSX.pdf