Quantcast

TeSys D Contactor, 3P(3 NO), AC-3, <= 440v,="" 12a,="" 380vac="">

TeSys D Contactor, 3P(3 NO), AC-3, <= 440v,="" 12a,="" 380vac="">

TeSys D Contactor, 3P(3 NO), AC-3, <= 440v,="" 12a,="" 380vac="">

Item Number: LC1D12Q7

Product Dimensions

Width icon

Width45 mm

Height icon

Height77 mm

Depth icon

Depth86 mm

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Sustainable offer status

Green Premium product

Warranty

18 months

Range of product

  • TeSys D
  • TeSys Deca

Range

  • TeSys
  • TeSys Deca

Product or component type

contactor

Physical

Insulation resistance

> 10 MOhm for signalling circuit

IP degree of protection

IP20 front face conforming to IEC 60529

Climatic withstand

  • conforming to IACS E10
  • conforming to IEC 60947-1 Annex Q category D

Ambient air temperature for operation

  • -40...60 °C
  • 60...70 °C with derating

Ambient air temperature for storage

-60...80 °C

Height

77 mm

Width

45 mm

Depth

86 mm

Net weight

0.325 kg

REACh Regulation

Free of Substances of Very High Concern above the threshold

REACh free of SVHC

Yes

EU RoHS Directive

Compliant

Toxic heavy metal free

Yes

Mercury free

Yes

RoHS exemption information

Yes

China RoHS Regulation

 Pro-active China RoHS declaration (out of China RoHS legal scope)

Environmental Disclosure

ENVPEP1501004

Circularity Profile

ENVEOLI1501004

California proposition 65

WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov

[Ue] rated operational voltage

  • power circuit: <= 690="" v="" ac="" 25...400="">
  • power circuit: <= 300="" v="">

[Ie] rated operational current

  • 25 A (at <60 °c)="" at=""><= 440="" v="" ac="" ac-1="" for="" power="">
  • 12 A (at <60 °c)="" at=""><= 440="" v="" ac="" ac-3="" for="" power="">
  • 12 A (at <60 °c)="" at=""><= 440="" v="" ac="" ac-3e="" for="" power="">

Electrical durability

  • 2 Mcycles 12 A AC-3 at Ue <= 440="">
  • 0.8 Mcycles 25 A AC-1 at Ue <= 440="">
  • 2 Mcycles 12 A AC-3e at Ue <= 440="">

Mounting support

  • rail
  • plate

Standards

  • CSA C22.2 No 14
  • EN 60947-4-1
  • EN 60947-5-1
  • IEC 60947-4-1
  • IEC 60947-5-1
  • UL 508
  • IEC 60335-1

Product certifications

  • CSA
  • DNV
  • BV
  • GL
  • UL
  • CCC
  • GOST
  • RINA
  • LROS (Lloyds register of shipping)
  • UKCA

Connections - terminals

  • power circuit: screw clamp terminals 1 cable(s) 1-4 mm²flexible without cable end
  • power circuit: screw clamp terminals 2 cable(s) 1-4 mm²flexible without cable end
  • power circuit: screw clamp terminals 1 cable(s) 1-4 mm²flexible with cable end
  • power circuit: screw clamp terminals 2 cable(s) 1-2.5 mm²flexible with cable end
  • power circuit: screw clamp terminals 1 cable(s) 1-4 mm²solid without cable end
  • power circuit: screw clamp terminals 2 cable(s) 1-4 mm²solid without cable end
  • control circuit: screw clamp terminals 1 cable(s) 1-4 mm²flexible without cable end
  • control circuit: screw clamp terminals 2 cable(s) 1-4 mm²flexible without cable end
  • control circuit: screw clamp terminals 1 cable(s) 1-4 mm²flexible with cable end
  • control circuit: screw clamp terminals 2 cable(s) 1-2.5 mm²flexible with cable end
  • control circuit: screw clamp terminals 1 cable(s) 1-4 mm²solid without cable end
  • control circuit: screw clamp terminals 2 cable(s) 1-4 mm²solid without cable end

Mechanical durability

15 Mcycles

Others

Coil technology

without built-in suppressor module

Control circuit voltage limits

  • 0.3...0.6 Uc (-40-70 °C):drop-out AC 50/60 Hz
  • 0.8...1.1 Uc (-40-60 °C):operational AC 50 Hz
  • 0.85...1.1 Uc (-40-60 °C):operational AC 60 Hz
  • 1...1.1 Uc (60-70 °C):operational AC 50/60 Hz

Inrush power in VA

  • 70 VA 60 Hz cos phi 0.75 (at 20 °C)
  • 70 VA 50 Hz cos phi 0.75 (at 20 °C)

Hold-in power consumption in VA

  • 7.5...7.5 VA 60 Hz cos phi 0.3 (at 20 °C)
  • 7 VA 50 Hz cos phi 0.3 (at 20 °C)

Heat dissipation

2...3 W at 50/60 Hz

Auxiliary contacts type

  • type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
  • type mirror contact 1 NC conforming to IEC 60947-4-1

Signalling circuit frequency

25...400 Hz

Minimum switching current

5 mA for signalling circuit

Minimum switching voltage

17 V for signalling circuit

Non-overlap time

  • 1.5 ms on de-energisation between NC and NO contact
  • 1.5 ms on energisation between NC and NO contact

Contact compatibility

M2

Compatibility code

LC1D

Power range

  • 4...6 kW at 380...440 V 3 phases
  • 4...6 kW at 480...500 V 3 phases
  • 1.1...2 kW at 100...120 V 3 phases
  • 2.2...3 kW at 200...240 V 3 phases
  • 7...11 kW at 525...690 V 3 phases

Motor starter type

direct on-line contactor

Protective treatment

TH conforming to IEC 60068-2-30

Pollution degree

3

Operating altitude

0...3000 m

Fire resistance

850 °C conforming to IEC 60695-2-1

Flame retardance

V1 conforming to UL 94

Mechanical robustness

  • vibrations contactor open: 2 Gn, 5...300 Hz
  • vibrations contactor closed: 4 Gn, 5...300 Hz
  • shocks contactor open: 10 Gn for 11 ms
  • shocks contactor closed: 15 Gn for 11 ms

Unit Type of Package 1

PCE

Number of Units in Package 1

1

Package 1 Weight

354.0 g

Package 1 Height

5 cm

Package 1 width

9.2 cm

Package 1 Length

11.2 cm

Unit Type of Package 2

P06

Number of Units in Package 2

160

Package 2 Weight

68.78 kg

Package 2 Height

45 cm

Package 2 width

80 cm

Package 2 Length

60 cm

Unit Type of Package 3

S02

Number of Units in Package 3

20

Package 3 Weight

7.402 kg

Package 3 Height

15 cm

Package 3 width

30 cm

Package 3 Length

40 cm

WEEE

The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

PVC free

Yes

Product name

  • TeSys D
  • TeSys Deca

Device short name

LC1D

Contactor application

  • resistive load
  • motor control

Utilisation category

  • AC-1
  • AC-4
  • AC-3
  • AC-3e

Poles description

3P

Pole contact composition

3 NO

Motor power kW

  • 3 kW at 220...230 V AC 50/60 Hz (AC-3)
  • 5.5 kW at 380...400 V AC 50/60 Hz (AC-3)
  • 5.5 kW at 415...440 V AC 50/60 Hz (AC-3)
  • 7.5 kW at 500 V AC 50/60 Hz (AC-3)
  • 7.5 kW at 660...690 V AC 50/60 Hz (AC-3)
  • 3.7 kW at 400 V AC 50/60 Hz (AC-4)
  • 3 kW at 220...230 V AC 50/60 Hz (AC-3e)
  • 5.5 kW at 380...400 V AC 50/60 Hz (AC-3e)
  • 5.5 kW at 415...440 V AC 50/60 Hz (AC-3e)
  • 7.5 kW at 500 V AC 50/60 Hz (AC-3e)
  • 7.5 kW at 660...690 V AC 50/60 Hz (AC-3e)

Motor power hp

  • 0.5 hp at 115 V AC 50/60 Hz for 1 phase motors
  • 2 hp at 230/240 V AC 50/60 Hz for 1 phase motors
  • 3 hp at 200/208 V AC 50/60 Hz for 3 phases motors
  • 3 hp at 230/240 V AC 50/60 Hz for 3 phases motors
  • 7.5 hp at 460/480 V AC 50/60 Hz for 3 phases motors
  • 10 hp at 575/600 V AC 50/60 Hz for 3 phases motors

Control circuit type

AC at 50/60 Hz

[Uc] control circuit voltage

380 V AC 50/60 Hz

Auxiliary contact composition

1 NO + 1 NC

[Uimp] rated impulse withstand voltage

6 kV conforming to IEC 60947

Overvoltage category

III

[Ith] conventional free air thermal current

  • 25 A (at 60 °C) for power circuit
  • 10 A (at 60 °C) for signalling circuit

Irms rated making capacity

  • 250 A at 440 V for power circuit conforming to IEC 60947
  • 140 A AC for signalling circuit conforming to IEC 60947-5-1
  • 250 A DC for signalling circuit conforming to IEC 60947-5-1

Rated breaking capacity

250 A at 440 V for power circuit conforming to IEC 60947

[Icw] rated short-time withstand current

  • 105 A 40 °C - 10 s for power circuit
  • 210 A 40 °C - 1 s for power circuit
  • 30 A 40 °C - 10 min for power circuit
  • 61 A 40 °C - 1 min for power circuit
  • 100 A - 1 s for signalling circuit
  • 120 A - 500 ms for signalling circuit
  • 140 A - 100 ms for signalling circuit

Associated fuse rating

  • 10 A gG for signalling circuit conforming to IEC 60947-5-1
  • 40 A gG at <= 690="" v="" coordination="" type="" 1="" for="" power="">
  • 25 A gG at <= 690="" v="" coordination="" type="" 2="" for="" power="">

Average impedance

2.5 mOhm - Ith 25 A 50 Hz for power circuit

[Ui] rated insulation voltage

  • power circuit: 690 V conforming to IEC 60947-4-1
  • power circuit: 600 V CSA certified
  • power circuit: 600 V UL certified
  • signalling circuit: 690 V conforming to IEC 60947-1
  • signalling circuit: 600 V CSA certified
  • signalling circuit: 600 V UL certified

Power dissipation per pole

  • 0.36 W AC-3
  • 1.56 W AC-1
  • 0.36 W AC-3e

Protective cover

with

Tightening torque

  • power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
  • power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2
  • control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
  • control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2
  • control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver pozidriv No 2
  • power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver pozidriv No 2

Operating time

  • 12...22 ms closing
  • 4...19 ms opening

Safety reliability level

  • B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
  • B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1

Maximum operating rate

3600 cyc/h 60 °C
Show all specifications

Documents & downloads

hide show
Filter items
  • All

  • CAD Files and Packs

  • Product Brochures

  • Technical Data Catalogues

  • Installation Instruction

  • End of Life Manual

  • Product Environmental

  • Data Bulletin

  • Technical Drawing

  • Certificates (MSDS)

  • Declaration of Conformity