Gv2 GV3 Undervolt 240V Rhs Mount

Gv2 GV3 Undervolt 240V Rhs Mount

Gv2 GV3 Undervolt 240V Rhs Mount

Item Number: GVAX225

Retail
$369.06
RRP (Inc. GST)

Product Dimensions

Width icon

Width18 mm

Height icon

Height89 mm

Depth icon

Depth66 mm

See full specifications

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range of product

TeSys GV2

Range

TeSys

Product or component type

safety undervoltage trip

Sustainable offer status

Green Premium product

Warranty

18 months

Physical

Range compatibility

GV2ME

Connections - terminals

  • screw clamp terminals 1 cable(s) 1-2.5 mm²solid
  • screw clamp terminals 2 cable(s) 1-2.5 mm²solid
  • screw clamp terminals 1 cable(s) 0.75-2.5 mm²flexible without cable end
  • screw clamp terminals 2 cable(s) 0.75-2.5 mm²flexible without cable end
  • screw clamp terminals 1 cable(s) 0.75-1.5 mm²flexible with cable end
  • screw clamp terminals 2 cable(s) 0.75-1.5 mm²flexible with cable end
    • Mechanical durability

      30000 cycles

      Quantity per set

      set of 10

      Height

      89 mm

      Width

      18 mm

      Depth

      66 mm

      Net weight

      0.105 kg

      REACh free of SVHC

      Yes

      EU RoHS Directive

      Compliant

      Toxic heavy metal free

      Yes

      Mercury free

      Yes

      RoHS exemption information

      Yes

      China RoHS Regulation

      X

      Environmental Disclosure

      ENVPEP111252EN

      Others

      Device short name

      GVAX

      [Uc] control circuit voltage

      220...240 V AC 50 Hz

      Control circuit voltage limits

      0.85...1.1 Un

      [Ui] rated insulation voltage

    • 690 V AC conforming to IEC 60947-1
    • 600 V AC conforming to UL 60947-4-1
    • 600 V AC conforming to CSA C22.2 No 60947-4-1
      • Threshold tripping voltage

        0.7...0.35 Un

        Inrush power in VA

        12-12 VA AC

        Inrush power in W

        8 W

        Hold-in power consumption in VA

        3.5-3.5 VA AC

        Hold-in power consumption in W

        1.1-1.1 W

        Operating time

        10...15 ms conforming to IEC 60947-1

        On-load factor

        100 %

        Tightening torque

        < 1.4 N.m on screw clamp terminals

        Compatibility code

        GVAX

        Unit Type of Package 1

        PCE

        Number of Units in Package 1

        1

        Package 1 Weight

        131 g

        Package 1 Height

        3.5 cm

        Package 1 width

        8.5 cm

        Package 1 Length

        9.2 cm

        Unit Type of Package 2

        S01

        Number of Units in Package 2

        16

        Package 2 Weight

        2.256 kg

        Package 2 Height

        15 cm

        Package 2 width

        15 cm

        Package 2 Length

        40 cm

        WEEE

        The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
        Show all specifications

        Documents & downloads

        hide show
        Filter items
        • All

        • Product Brochures

        • Technical Data Catalogues

        • Product Environmental

        • Installation Instruction

        • eTechPub

        Frequently Asked Questions

        hide show

        Can GVAU225 operate on 60 HZ?

        Do we offer a cable operated handle mechanism for the GV7 starters?

        Issue:
        They need to mount the GV7 back inside the enclosure and need a handle mechanism with a cable to operate. 

        Product line:
        Manual Starters and Protectors

        Environment:
        Tesys GV7 manual motor controller

        Resolution:
        The GV7 do not offer a cable operator.  Consider switching to a Powerpact circuit breaker which offers the cable mechanism kits.

        What is the catalog number for an external rotary handle for a GV7 manual starter ?

        Issue:
        GV7 Manual starter handle kit

        Product Line:
        Motor Starters and Protectors

        Environment:
        TeSys™ GV Manual Starters and Protectors

        Resolution:
        Use the GV7AP01 for a black handle with black legend or a GV7AP02 for a red handle with yellow legend.

        What is the part number for the top mount auxiliary for a GV2L22?

        The part number for the Top mount auxiliary for the GV2 range is the GVAE1....
        This can be a N/O or N/C depending on orientation
        https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=gvae1

        User-added image

        What is the IP rating of GVAE20? Would the IP rating of GV2P circuit breaker (IP20) get affected by the addition of Aux contact GVAE20?

        The IP rating of GVAE20 is IP 20.

        The IP rating of GV2* with GVAE20 is then IP20. It would not get affected by the addition of the Auxiliary 

        Will the accessories used for the GV3ME06 through GV3ME63 work with the GV3ME80?

        Product Line:
        GV3 manual motor starters, IEC

        Resolution:
        The standard GV3 accessories will work on this device.
        Show More