Quantcast

Gv2 GV3 Auxiliary N/C(Flt) N/O Lhs

Gv2 GV3 Auxiliary N/C(Flt) N/O Lhs

Gv2 GV3 Auxiliary N/C(Flt) N/O Lhs

Item Number: GVAD0110

Retail
$155.18
RRP (Inc. GST)

Product Dimensions

Width icon

Width9.3 mm

Height icon

Height89 mm

Depth icon

Depth66 mm

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range of product

  • TeSys GV3
  • TeSys GV2
    • Range

      TeSys

      Product or component type

      auxiliary contact block

      Product compatibility

    • GV2ME
    • GV2L
    • GV3P
    • GV2P
    • GV3L
    • GV2LE
    • GV2RT
      • Sustainable offer status

        Green Premium product

        Warranty

        18 months

        Physical

        [Ue] rated operational voltage

      • 48...690 V AC
      • 24...240 V DC
        • Protection type

        • GB2CB... circuit breaker
        • gG fuse 10 A
          • Mechanical durability

            100000 cycles

            Height

            89 mm

            Width

            9.3 mm

            Depth

            66 mm

            Net weight

            0.055 kg

            Environmental characteristic

            normal environment

            Product certifications

            UKCA

            REACh Regulation

            Free of Substances of Very High Concern above the threshold

            REACh free of SVHC

            Yes

            EU RoHS Directive

            Compliant

            Toxic heavy metal free

            Yes

            Mercury free

            Yes

            RoHS exemption information

            Yes

            China RoHS Regulation

            X

            Environmental Disclosure

            ENVPEP111252EN

            California proposition 65

            WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov

            Others

            Device short name

            GVAD

            Mounting location

            left side

            Auxiliary contacts operation

            fault signal 1 NC

            Pole contact composition

            1 NO + 1 NC

            [Ui] rated insulation voltage

          • 690 V conforming to IEC 60947-1
          • 300 V conforming to UL 508
          • 300 V conforming to CSA C22.2 No 14
            • [Ith] conventional free air thermal current

            • 6 A
            • 2.5 A for fault signalling
              • Minimum switching current

                5 mA

                Minimum switching voltage

                17 V

                Rated operational power in VA

              • 300 VA at 48-48 V AC-15 - electrical durability: 100000 cycles
              • 414 VA at 690-690 V AC-15 - electrical durability: 100000 cycles
              • 500 VA at 110-127 V AC-15 - electrical durability: 100000 cycles
              • 500 VA at 500-500 V AC-15 - electrical durability: 100000 cycles
              • 650 VA at 440-440 V AC-15 - electrical durability: 100000 cycles
              • 720 VA at 230-240 V AC-15 - electrical durability: 100000 cycles
              • 850 VA at 380-415 V AC-15 - electrical durability: 100000 cycles
              • 36 VA at 24-24 V AC-14 - electrical durability: 1000 cycles
              • 48 VA at 48-48 V AC-14 - electrical durability: 1000 cycles
              • 72 VA at 110-127 V AC-14 - electrical durability: 1000 cycles
                • Rated operational power in W

                • 120 W at 240 V DC-13 - electrical durability: 100000 cycles
                • 140 W at 110 V DC-13 - electrical durability: 100000 cycles
                • 140 W at 24 V DC-13 - electrical durability: 100000 cycles
                • 180 W at 60 V DC-13 - electrical durability: 100000 cycles
                • 240 W at 48 V DC-13 - electrical durability: 100000 cycles
                • 15 W at 48 V DC-13 - electrical durability: 1000 cycles
                • 24 W at 24 V DC-13 - electrical durability: 1000 cycles
                • 9 W at 60 V DC-13 - electrical durability: 1000 cycles
                  • Tightening torque

                    1.4 N.m - on screw clamp terminals

                    Compatibility code

                    GVAD

                    Unit Type of Package 1

                    PCE

                    Number of Units in Package 1

                    1

                    Package 1 Weight

                    46.1 g

                    Package 1 Height

                    0.951 cm

                    Package 1 width

                    6.578 cm

                    Package 1 Length

                    8.905 cm

                    Unit Type of Package 2

                    BB1

                    Number of Units in Package 2

                    10

                    Package 2 Weight

                    500 g

                    Package 2 Height

                    9.5 cm

                    Package 2 width

                    10 cm

                    Package 2 Length

                    15 cm

                    Unit Type of Package 3

                    S02

                    Number of Units in Package 3

                    60

                    Package 3 Weight

                    3.455 kg

                    Package 3 Height

                    15 cm

                    Package 3 width

                    30 cm

                    Package 3 Length

                    40 cm

                    WEEE

                    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
                    Show all specifications

                    Documents & downloads

                    hide show
                    Filter items
                    • All

                    • CAD Files and Packs

                    • Product Brochures

                    • Technical Data Catalogues

                    • Installation Instruction

                    • Product Environmental

                    • Technical Drawing

                    • eTechPub

                    Frequently Asked Questions

                    hide show

                    What is the operation of the GV2AD fault signalling contacts of the GV2 motor protection circuit breakers?

                    GV2ME, GV2P, GV2L, GV2LE, GV3P and GV3L Motor protection circuit breakers (MPCB) can be fitted with the following optional fault indicating contact blocks:
                     

                    GVAD0110
                    GVAD0101
                    GVAD1010
                    GVAD1001

                    These blocks comprise of fault signalling contacts and instantaneous auxiliary contacts

                    GVAD0110

                    A N/O instantaneous auxiliary contact (terminals 53-54), closed when the device is energized and open when the device is de-energized

                    A N/C fault signalling contact (terminals 95-96), closed if there is no fault, open when a fault (magnetic or thermal) occurs. 

                    GVAD0101

                    A N/C instantaneous auxiliary contact (terminals 51-52), closed when the device is de-energised and open when the device is energised.

                    A N/C fault signalling contact (terminals 95-96), closed if there is no fault, open when a fault (magnetic or thermal) occurs. 

                    GVAD1010 

                    A N/O instantaneous auxiliary contact (terminals 53-54), closed when the device is energized and open when the device is de-energized.

                    A N/O fault signalling contact (terminals 97-98), open if there is no fault, closed when a fault (magnetic or thermal) occurs. 
                     

                    GVAD1001

                    A N/C instantaneous auxiliary contact (terminals 51-52), closed when the device is de-energized and open when the device is energized.

                    A N/O fault signalling contact (terminals 97-98), open if there is no fault, closed when a fault (magnetic or thermal) occurs. 
                     


                    The instantaneous auxiliary contact test is performed by creating a state of transition of the handle actuator between the de-energized position and the energized position.

                    The fault contact test is performed by pressing the test button when the handle actuator is in the closed position.