Quantcast

Motor Breaker GV4PE Multi Th/Magnetic 115A 100kA Lug Terminal

Motor Breaker GV4PE Multi Th/Magnetic 115A 100kA Lug Terminal

Motor Breaker GV4PE Multi Th/Magnetic 115A 100kA Lug Terminal

Item Number: GV4PEM115S6

Retail
$2,173.45
RRP (Inc. GST)

Product Dimensions

Width icon

Width81 mm

Height icon

Height155 mm

Depth icon

Depth116 mm

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Sustainable offer status

Green Premium product

Warranty

18 months

Range

TeSys

Product or component type

multifunction circuit breaker

Device application

motor protection

Physical

Circularity Profile

ENVEOLI1704004EN

Environmental Disclosure

ENVPEP1704004EN

Mercury free

Yes

REACh Regulation

Free of Substances of Very High Concern above the threshold

China RoHS Regulation

Product out of China RoHS scope. Substance declaration for your information

EU RoHS Directive

Compliant

RoHS exemption information

Yes

Protection type

  • long start
  • short-circuit
  • overload
  • phase loss
  • jam
  • short time short-circuit protection
  • ground fault protection
  • phase unbalance
  • locked rotor
    • [Ue] rated operational voltage

      690 V AC 50/60 Hz conforming to IEC 60947-2

      [In] rated current

      115 A

      Mechanical durability

      40000 cycles

      Electrical durability

    • 10000 cycles for AC-3 at 440 V In/2
    • 5000 cycles for AC-3 at 440 V In
      • Control type

        toggle

        Local signalling

      • flashing LED (green) for ready
      • LED (red) for alarm (T° >95%)
      • green indicator for presence of auxiliary contacts
        • Communication port protocol

          NFC

          Standards

        • CSA C22.2 No 60947-4-1
        • UL 60947-4-1
        • EN/IEC 60947-2
        • EN/IEC 60947-4-1
          • Product certifications

          • IEC
          • UL
          • CSA
          • CCC
          • EAC
          • ATEX
          • EU-RO MR
            • Mounting mode

            • by clips
            • by screws
              • Mounting support

              • 75 mm symmetrical DIN rail
              • plate
              • 35 mm symmetrical DIN rail
                • Connections - terminals

                  lugs-ring terminals

                  Width

                  81 mm

                  Height

                  155 mm

                  Depth

                  116 mm

                  Net weight

                  1.45 kg

                  Ambient air temperature for storage

                  -50-85 °C

                  Ambient air temperature for operation

                  -25-70 °C

                  IP degree of protection

                  IP40 front face conforming to IEC 60529

                  IK degree of protection

                  IK07 conforming to IEC 62262

                  Others

                  Halogen content performance

                  Halogen free plastic parts product

                  Package 1 Height

                  16.5 cm

                  Package 1 Length

                  22 cm

                  Package 1 Weight

                  1.43 kg

                  Package 1 width

                  11 cm

                  PVC free

                  Yes

                  WEEE

                  The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

                  Product name

                  TeSys GV4

                  Device short name

                  GV4PEM

                  Utilisation category

                  category A

                  Suitability for isolation

                  yes conforming to IEC 60947-1

                  Poles description

                  3P

                  Trip unit technology

                • thermal-magnetic
                • electronic
                  • Magnetic tripping current

                    1955-1955 A

                    [Isd] short-time pick-up adjustment range

                    5...13 x Ir

                    Thermal protection adjustment range

                    65-115 A

                    Motor tripping class

                  • 10
                  • 20
                    • Phase failure sensitivity

                      yes conforming to IEC 60947-4-1

                      Breaking capacity

                    • Icu 120 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2
                    • Icu 100 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2
                    • Icu 70 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
                    • Icu 30 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
                    • Icu 18 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2
                    • 100 kA at 208Y/120 V AC 50/60 Hz conforming to UL 60947
                    • 100 kA at 240 V AC 50/60 Hz conforming to UL 60947
                    • 65 kA at 480Y/277 V AC 50/60 Hz conforming to UL 60947
                    • Icu 10 kA at 660...690 V AC 50/60 Hz conforming to IEC 60947-2
                    • 25 kA at 600Y/347 V AC 50/60 Hz conforming to UL 60947
                      • [Ics] rated service breaking capacity

                      • 120 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2
                      • 100 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2
                      • 70 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
                      • 30 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
                      • 18 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2
                      • 2.5 kA at 660...690 V AC 50/60 Hz conforming to IEC 60947-2
                        • [Uimp] rated impulse withstand voltage

                          [Ui] rated insulation voltage

                          800 V conforming to IEC 60947-2

                          Motor power kW

                        • 37-37 kW at 400...415 V AC 50/60 Hz
                        • 45-45 kW at 400...415 V AC 50/60 Hz
                        • 55-55 kW at 400...415 V AC 50/60 Hz
                        • 45-45 kW at 500 V AC 50/60 Hz
                        • 55-55 kW at 500 V AC 50/60 Hz
                        • 75-75 kW at 500 V AC 50/60 Hz
                        • 75-75 kW at 660...690 V AC 50/60 Hz
                        • 90-90 kW at 660...690 V AC 50/60 Hz
                        • 110-110 kW at 660...690 V AC 50/60 Hz
                          • Rotary handle padlocking

                            with a lock accessory

                            Number of slots

                          • 1 slot(s) for alarm switch for fault signalling contact, plug-in
                          • 1 slot(s) for voltage release for electrical remote tripping, plug-in
                          • 1 slot(s) for auxiliary switch for open/close contact, plug-in
                            • Quality labels

                              CE

                              Connection pitch

                              27 mm

                              Tightening torque

                            • 9-9 N.m for 16-95 mm²
                            • 5-5 N.m for 1.5-10 mm²
                              • Operating altitude

                              • 0...2000 m without derating
                              • 2000...5000 m with derating
                                • Pollution degree

                                  3 conforming to IEC 60947-1

                                  Tropicalisation

                                  2 conforming to IEC 68-2

                                  Mechanical robustness

                                • vibrations: +/- 1 mm 2...13.2 Hz conforming to IEC 60068-2-6
                                • vibrations: 0.7 gn 13.2...100 Hz conforming to IEC 60068-2-6
                                • shocks: 15 gn 11 ms conforming to IEC 60068-2-27
                                  • Show all specifications