Quantcast

Gv2 Motor CB High Inrush 1.6-2.5A Toggle

Product Dimensions

Width icon

Width45 mm

Height icon

Height89 mm

Depth icon

Depth78.5 mm

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range

TeSys

Range of product

TeSys GV2

Product or component type

circuit breaker

Device application

  • transformer
  • motor
    • Sustainable offer status

      Green Premium product

      Warranty

      18 months

      Physical

      Fixing mode

    • 35 mm symmetrical DIN rail: clipped
    • panel: screwed (with adaptor plate)
      • Control type

        toggle

        [In] rated current

        2.5 A

        [Ue] rated operational voltage

        690 V AC 50/60 Hz conforming to IEC 60947-2

        Mechanical durability

        100000 cycles

        Electrical durability

        100000 cycles for AC-3 at 440 V

        Height

        89 mm

        Width

        45 mm

        Depth

        78.5 mm

        Standards

      • EN/IEC 60947-2
      • EN/IEC 60947-4-1
      • UL 60947-4-1
      • CSA C22.2 No 60947-4-1
        • Product certifications

        • IECEE CB Scheme
        • UL
        • CSA
        • CCC
        • EAC
        • BV
        • LROS (Lloyds register of shipping)
          • IP degree of protection

            IP20 conforming to IEC 60529

            IK degree of protection

            IK04

            Ambient air temperature for operation

            -20-60 °C

            Ambient air temperature for storage

            -40-80 °C

            REACh Regulation

            Free of Substances of Very High Concern above the threshold

            EU RoHS Directive

            Compliant

            Mercury free

            Yes

            RoHS exemption information

            Yes

            China RoHS Regulation

            Product out of China RoHS scope. Substance declaration for your information

            Environmental Disclosure

            ENVPEP121004EN

            California proposition 65

            WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov

            Others

            Product name

            TeSys GV2

            Device short name

            GV2RT

            Trip unit technology

            thermal-magnetic

            Poles description

            3P

            Network type

            AC

            Utilisation category

          • AC-3 conforming to IEC 60947-4-1
          • category A conforming to IEC 60947-2
            • Network frequency

              50/60 Hz conforming to IEC 60947-4-1

              Operating position

              any position

              Motor power kW

            • 0.37-0.37 kW at 220/230 V AC 50/60 Hz motor protection high peak current
            • 0.75-0.75 kW at 400/415 V AC 50/60 Hz motor protection high peak current
            • 0.75-0.75 kW at 440 V AC 50/60 Hz motor protection high peak current
            • 1.1-1.1 kW at 440 V AC 50/60 Hz motor protection high peak current
            • 1.1-1.1 kW at 500 V AC 50/60 Hz motor protection high peak current
            • 1.5-1.5 kW at 690 V AC 50/60 Hz motor protection high peak current
            • 0.63-0.63 kW at 230/240 V AC 50/60 Hz transformer protection
            • 1-1 kW at 400/415 V AC 50/60 Hz transformer protection
            • 1.6-1.6 kW at 500 V AC 50/60 Hz transformer protection
            • 1.6-1.6 kW at 690 V AC 50/60 Hz transformer protection
            • 2-2 kW at 690 V AC 50/60 Hz transformer protection
              • Breaking capacity

              • 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
              • 100 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
              • 100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
              • 3 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
              • 100 kA Icu at 220/230 V AC 50/60 Hz conforming to IEC 60947-2
                • Trip unit rating

                  1.6-2.5 A

                  Magnetic tripping current

                  51-51 A

                  [Ui] rated insulation voltage

                  690 V AC 50/60 Hz conforming to IEC 60947-2

                  [Ith] conventional free air thermal current

                  2.5 A conforming to IEC 60947-4-1

                  [Uimp] rated impulse withstand voltage

                  Power dissipation per pole

                  2.5 W

                  Maximum operating rate

                  25 cyc/h

                  Rated duty

                  continuous conforming to IEC 60947-4-1

                  Direct connector

                  without

                  Tightening torque

                  1.7 N.m on screw clamp terminals

                  Suitability for isolation

                  yes conforming to IEC 60947-1

                  Compatibility code

                  GV2RT

                  Protective treatment

                  TH

                  Fire resistance

                  960 °C conforming to IEC 60695-2-1

                  Operating altitude

                  2000 m

                  Unit Type of Package 1

                  PCE

                  Number of Units in Package 1

                  1

                  Package 1 Weight

                  253 g

                  Package 1 Height

                  4.8 cm

                  Package 1 width

                  8.5 cm

                  Package 1 Length

                  9.5 cm

                  Unit Type of Package 2

                  S02

                  Number of Units in Package 2

                  24

                  Package 2 Weight

                  6.388 kg

                  Package 2 Height

                  15 cm

                  Package 2 width

                  30 cm

                  Package 2 Length

                  40 cm

                  Unit Type of Package 3

                  P06

                  Number of Units in Package 3

                  384

                  Package 3 Weight

                  128.507 kg

                  Package 3 Height

                  80 cm

                  Package 3 width

                  80 cm

                  Package 3 Length

                  60 cm

                  WEEE

                  The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
                  Show all specifications

                  Documents & downloads

                  hide show
                  Filter items
                  • All

                  • CAD Files and Packs

                  • Product Brochures

                  • Technical Data Catalogues

                  • Product Environmental

                  • Installation Instruction

                  • Data Bulletin

                  • eTechPub

                  Frequently Asked Questions

                  hide show

                  Can the GV* starters be used on 50 hertz applications?

                  Issue:
                  GV* Starter for 50/60hz application

                  Product Line:
                  Motor Starters and Protectors

                  Environment:
                  PowerPact™ Manual Starters

                  Resolution:
                  Yes, these starters are rated for 50/60 hertz.

                  This applies to all GV2M, GV2ME, GV2P, GV3M, GV3ME devices.

                  What is the tripping class of the GV2 ME, GV2 P and GV2 RT?

                  The tripping class for GV2MExx, GV2Pxx, GV2RTxx motor protection circuit-breakers (MPCB) is class 10. Class 10 corresponds to a direct on-line motor starting time between 4 and 10 sec. Example of a tripping curve:




                   

                  What items does the GV2PC02 enclosure suit?

                  The GV2PC02 is for GV2P and GV2L, 0.55 to 15kW.

                  What would be the part number for an enclosure for the GV2ME20

                  Can GVAE1, GVAE11 or GVAE20 be used with GV3 starters?

                  Issue:
                  Are the front mount auxiliary contacts GVAE1, GVEA11 and GVAE20 be used for GV3M devices?
                   
                  Product Line:

                  Tesys GV Manual Starter and Protectors

                  Environment:
                  TeSys GV, GVA, GV2, GV3P

                  Resolution:
                  These auxiliary contacts can only be used with the rotary handled GV3P devices. They cannot be applied with the pushbutton GV3M devices.