Quantcast

Gv2 Motor CB High Inrush 1-1.6A Toggle

Gv2 Motor CB High Inrush 1-1.6A Toggle

Gv2 Motor CB High Inrush 1-1.6A Toggle

Item Number: GV2RT06

Datasheet

Product Dimensions

Width icon

Width45 mm

Height icon

Height89 mm

Depth icon

Depth78.5 mm

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range

TeSys Deca

Range of product

TeSys GV2

Product or component type

motor circuit breaker

Device application

  • motor protection
  • motor

Sustainable offer status

Green Premium product

Warranty

18 months

Physical

Fixing mode

  • 35 mm symmetrical DIN rail: clipped
  • panel: screwed (with adaptor plate)

Control type

toggle

[In] rated current

1.6 A

[Ue] rated operational voltage

690 V AC 50/60 Hz conforming to IEC 60947-2

Mechanical durability

100000 cycles

Electrical durability

  • 100000 cycles for AC-3 at 415 V
  • at 415 V

Height

89 mm

Width

45 mm

Depth

78.5 mm

Standards

  • EN/IEC 60947-2
  • EN/IEC 60947-4-1

Product certifications

  • CCC
  • UL
  • CSA
  • EAC
  • BV
  • LROS (Lloyds register of shipping)
  • UKCA

Climatic withstand

conforming to IACS E10

IK degree of protection

IK04

IP degree of protection

IP20 conforming to IEC 60529

Ambient air temperature for storage

-40...80 °C

Ambient air temperature for operation

-20...60 °C

REACh Regulation

Reference contains Substances of Very High Concern above the threshold

EU RoHS Directive

Compliant

Mercury free

Yes

RoHS exemption information

Yes

China RoHS Regulation

Product out of China RoHS scope. Substance declaration for your information

Environmental Disclosure

ENVPEP121004EN

Circularity Profile

ENVEOLI121004EN

California proposition 65

WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov

Others

Device short name

GV2RT

Product name

  • TeSys GV2
  • TeSys Deca

Trip unit technology

thermal-magnetic

Poles description

3P

Network type

AC

Utilisation category

  • AC-3 conforming to IEC 60947-4-1
  • category A conforming to IEC 60947-2

Network frequency

50/60 Hz conforming to IEC 60947-4-1

Operating position

any position

Motor power kW

  • 0.37...0.37 kW at 400/415 V AC 50/60 Hz motor protection high peak current
  • 0.37...0.37 kW at 440 V AC 50/60 Hz motor protection high peak current
  • 0.37...0.37 kW at 500 V AC 50/60 Hz motor protection high peak current
  • 0.18...0.18 kW at 220/230 V AC 50/60 Hz motor protection high peak current
  • 0.25...0.25 kW at 220/230 V AC 50/60 Hz motor protection high peak current
  • 0.55...0.55 kW at 400/415 V AC 50/60 Hz motor protection high peak current
  • 0.55...0.55 kW at 440 V AC 50/60 Hz motor protection high peak current
  • 0.55...0.55 kW at 500 V AC 50/60 Hz motor protection high peak current
  • 0.75...0.75 kW at 500 V AC 50/60 Hz motor protection high peak current
  • 0.75...0.75 kW at 690 V AC 50/60 Hz motor protection high peak current
  • 1.1.1 kW at 690 V AC 50/60 Hz motor protection high peak current
  • 0.4...0.4 kW at 230/240 V AC 50/60 Hz transformer protection
  • 0.63...0.63 kW at 400/415 V AC 50/60 Hz transformer protection

Breaking capacity

  • 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
  • 100 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
  • 100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
  • 100 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
  • 100 kA Icu at 220/230 V AC 50/60 Hz conforming to IEC 60947-2

Trip unit rating

1.6 A

Magnetic tripping current

33 A

[Ui] rated insulation voltage

690 V AC 50/60 Hz conforming to IEC 60947-2

[Ith] conventional free air thermal current

1.6 A conforming to IEC 60947-4-1

[Uimp] rated impulse withstand voltage

6 kV conforming to IEC 60947-2

Power dissipation per pole

2.5 W

Maximum operating rate

25 cyc/h

Rated duty

continuous conforming to IEC 60947-4-1

Direct connector

without

Tightening torque

1.7 N.m on screw clamp terminals

Mechanical robustness

  • shocks: 30 Gn conforming to IEC 60068-2-27
  • vibrations: 5 Gn, 5...150 Hz conforming to IEC 60068-2-6

Compatibility code

GV2RT

Suitability for isolation

yes conforming to IEC 60947-1 § 7-1-6

Fire resistance

960 °C conforming to IEC 60695-2-11

Operating altitude

2000 m

Unit Type of Package 1

PCE

Number of Units in Package 1

1

Package 1 Weight

260.0 g

Package 1 Height

8.2 cm

Package 1 width

9.0 cm

Package 1 Length

4.8 cm

Unit Type of Package 2

S02

Number of Units in Package 2

24

Package 2 Weight

6.39 kg

Package 2 Height

15.0 cm

Package 2 width

30.0 cm

Package 2 Length

40.0 cm

Unit Type of Package 3

P06

Number of Units in Package 3

384

Package 3 Weight

110.74 kg

Package 3 Height

77.0 cm

Package 3 width

80.0 cm

Package 3 Length

60.0 cm

WEEE

The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins