Quantcast

TeSys D, Control Relay, 5 NO, <= 690v,="" 480vac,="" standard="">

TeSys D, Control Relay, 5 NO, <= 690v,="" 480vac,="" standard="">

TeSys D, Control Relay, 5 NO, <= 690v,="" 480vac,="" standard="">

Item Number: CAD50T7

Datasheet

Product Dimensions

Width icon

Width45 mm

Height icon

Height77 mm

Depth icon

Depth84 mm

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range

TeSys

Range of product

TeSys D control relay

Product or component type

control relay

Warranty

18 months

Physical

[Ue] rated operational voltage

<= 690="" v="" ac="" 25...400="">

Mounting support

  • rail
  • plate

Connections - terminals

  • screw clamp terminals 1 cable(s) 1-4 mm²flexible without cable end
  • screw clamp terminals 2 cable(s) 1-4 mm²flexible without cable end
  • screw clamp terminals 1 cable(s) 1-4 mm²flexible with cable end
  • screw clamp terminals 2 cable(s) 1-2.5 mm²flexible with cable end
  • screw clamp terminals 1 cable(s) 1-4 mm²solid without cable end
  • screw clamp terminals 2 cable(s) 1-4 mm²solid without cable end

Mechanical durability

30 Mcycles

Insulation resistance

> 10 MOhm

Height

77 mm

Width

45 mm

Depth

84 mm

Net weight

0.58 kg

Standards

  • EN/IEC 60947-5-1
  • GB/T 14048.5
  • UL 60947-5-1
  • CSA C22.2 No 60947-5-1
  • JIS C8201-5-1

Product certifications

  • CB Scheme
  • CCC
  • UL
  • CSA
  • EAC
  • CE
  • UKCA

IP degree of protection

IP2X front face conforming to VDE 0106

Ambient air temperature for operation

  • -40...60 °C
  • 60...70 °C with derating

Ambient air temperature for storage

-60...80 °C

EU RoHS Directive

Compliant

Mercury free

Yes

RoHS exemption information

Yes

China RoHS Regulation

Product out of China RoHS scope. Substance declaration for your information

California proposition 65

WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov

Others

Package 1 Bare Product Quantity

1

Product name

TeSys CAD

Device short name

CAD

Contactor application

control circuit

Utilisation category

  • DC-13
  • AC-15
  • AC-14

Pole contact composition

5 NO

Control circuit type

AC at 50/60 Hz

[Uc] control circuit voltage

480 V AC 50/60 Hz

[Uimp] rated impulse withstand voltage

6 kV conforming to IEC 60947

[Ith] conventional free air thermal current

10 A (at 60 °C)

Irms rated making capacity

  • 140 A AC conforming to IEC 60947-5-1
  • 250 A DC conforming to IEC 60947-5-1

[Icw] rated short-time withstand current

  • 100 A - 1 s
  • 120 A - 500 ms
  • 140 A - 100 ms

Associated fuse rating

10 A gG conforming to IEC 60947-5-1

[Ui] rated insulation voltage

  • 600 V UL certified
  • 600 V CSA certified
  • 690 V conforming to IEC 60947-5-1

Tightening torque

  • 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2
  • 1.2 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm

Control circuit voltage limits

  • 0.3...0.6 Uc (-40-70 °C):drop-out AC 50/60 Hz
  • 0.8...1.1 Uc (-40-60 °C):operational AC 50 Hz
  • 0.85...1.1 Uc (-40-60 °C):operational AC 60 Hz
  • 1...1.1 Uc (60-70 °C):operational AC 50/60 Hz

Operating time

  • 12...22 ms coil energisation and NO closing
  • 4...12 ms coil de-energisation and NO opening

Maximum operating rate

180 cyc/mn

Inrush power in VA

70 VA 50 Hz (at 20 °C)

Hold-in power consumption in VA

8 VA 50 Hz (at 20 °C)

Minimum switching voltage

17 V

Minimum switching current

5 mA

Non-overlap time

  • 1.5 ms on energisation between NC and NO contact
  • 1.5 ms on de-energisation between NC and NO contact

Mechanical robustness

  • shocks control relay open: 10 Gn for 11 ms conforming to IEC 60068-2-27
  • shocks control relay closed: 15 Gn for 11 ms conforming to IEC 60068-2-27
  • vibrations control relay open: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
  • vibrations control relay closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6

Compatibility code

CAD

Protective treatment

TH conforming to IEC 60068

Operating altitude

0...3000 m

Unit Type of Package 1

PCE

Number of Units in Package 1

1

Package 1 Height

9.4 cm

Package 1 Width

8.1 cm

Package 1 Length

5.4 cm

Package 1 Weight

300 g

WEEE

The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
Show all specifications

Documents & downloads

hide show
Filter items
  • All

  • CAD Files and Packs

  • Technical Data Catalogues

  • Installation Instruction

  • End of Life Manual

  • Certificates (MSDS)

  • Declaration of Conformity