Quantcast

TeSys D, Control Relay, 5 NO, <= 690v,="" 72vdc,="" low="" consumption="">

TeSys D, Control Relay, 5 NO, <= 690v,="" 72vdc,="" low="" consumption="">

TeSys D, Control Relay, 5 NO, <= 690v,="" 72vdc,="" low="" consumption="">

Item Number: CAD50SL

Datasheet

Product Dimensions

Width icon

Width45 mm

Height icon

Height77 mm

Depth icon

Depth93 mm

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range

TeSys

Range of product

TeSys D control relay

Product or component type

control relay

Warranty

18 months

Physical

[Ue] rated operational voltage

<= 690="" v="" ac="" 25...400="">

Mounting support

  • plate
  • rail

Connections - terminals

  • screw clamp terminals 1 cable(s) 1-4 mm²flexible without cable end
  • screw clamp terminals 2 cable(s) 1-4 mm²flexible without cable end
  • screw clamp terminals 1 cable(s) 1-4 mm²flexible with cable end
  • screw clamp terminals 2 cable(s) 1-2.5 mm²flexible with cable end
  • screw clamp terminals 1 cable(s) 1-4 mm²solid without cable end
  • screw clamp terminals 2 cable(s) 1-4 mm²solid without cable end

Mechanical durability

30 Mcycles

Insulation resistance

> 10 MOhm

Height

77 mm

Width

45 mm

Depth

93 mm

Net weight

0.58 kg

Standards

  • EN/IEC 60947-5-1
  • GB/T 14048.5
  • UL 60947-5-1
  • CSA C22.2 No 60947-5-1
  • JIS C8201-5-1

Product certifications

  • CB Scheme
  • CCC
  • UL
  • CSA
  • EAC
  • CE
  • UKCA

IP degree of protection

IP2X conforming to VDE 0106

Ambient air temperature for operation

  • -40...60 °C
  • 60...70 °C with derating

Ambient air temperature for storage

-60...80 °C

Others

Product name

TeSys CAD

Device short name

CAD

Contactor application

control circuit

Utilisation category

  • AC-15
  • DC-13
  • AC-14

Pole contact composition

5 NO

Control circuit type

DC low consumption

[Uc] control circuit voltage

72 V DC

[Uimp] rated impulse withstand voltage

6 kV conforming to IEC 60947

[Ith] conventional free air thermal current

10 A (at 60 °C)

Irms rated making capacity

  • 140 A AC conforming to IEC 60947-5-1
  • 250 A DC conforming to IEC 60947-5-1

[Icw] rated short-time withstand current

  • 100 A - 1 s
  • 120 A - 500 ms
  • 140 A - 100 ms

Associated fuse rating

10 A gG conforming to IEC 60947-5-1

[Ui] rated insulation voltage

  • 600 V UL certified
  • 600 V CSA certified
  • 690 V conforming to IEC 60947-5-1

Tightening torque

  • 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2
  • 1.2 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm

Control circuit voltage limits

  • 0.1...0.25 Uc (-40-70 °C):drop-out DC
  • 0.7...1.25 Uc (-40-60 °C):operational DC
  • 1...1.25 Uc (60-70 °C):operational DC

Operating time

  • 65...88 ms coil energisation and NO closing
  • 14...25 ms coil de-energisation and NO opening

Maximum operating rate

180 cyc/mn

Time constant

40 ms

Inrush power in W

2.4...2.4 W (at 20 °C)

Hold-in power consumption in W

2.4...2.4 W at 20 °C

Minimum switching voltage

17 V

Minimum switching current

5 mA

Non-overlap time

  • 1.5 ms on energisation between NC and NO contact
  • 1.5 ms on de-energisation between NC and NO contact

Mechanical robustness

  • shocks control relay open: 10 Gn for 11 ms conforming to IEC 60068-2-27
  • shocks control relay closed: 15 Gn for 11 ms conforming to IEC 60068-2-27
  • vibrations control relay open: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
  • vibrations control relay closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6

Compatibility code

CAD

Protective treatment

TH conforming to IEC 60068

Operating altitude

0...3000 m

Unit Type of Package 1

PCE

Number of Units in Package 1

1