Quantcast

TeSys D Control Relay, 5 NO, <= 690V, 500VAC, Standard Coil

TeSys D Control Relay, 5 NO, <= 690V, 500VAC, Standard Coil

TeSys D Control Relay, 5 NO, <= 690V, 500VAC, Standard Coil

Item Number: CAD50S7

Retail
N/A
RRP (Inc. GST)

Product Dimensions

Width icon

Width45 mm

Height icon

Height77 mm

Depth icon

Depth84 mm

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range

TeSys

Range of product

TeSys D control relay

Product or component type

control relay

Warranty

18 months

Physical

[Ue] rated operational voltage

<= 690 V AC 25...400 Hz

Mounting support

  • plate
  • rail
    • Connections - terminals

    • screw clamp terminals 1 cable(s) 1-4 mm²flexible without cable end
    • screw clamp terminals 2 cable(s) 1-4 mm²flexible without cable end
    • screw clamp terminals 1 cable(s) 1-4 mm²flexible with cable end
    • screw clamp terminals 2 cable(s) 1-2.5 mm²flexible with cable end
    • screw clamp terminals 1 cable(s) 1-4 mm²solid without cable end
    • screw clamp terminals 2 cable(s) 1-4 mm²solid without cable end
      • Mechanical durability

        30 Mcycles

        Insulation resistance

        > 10 MOhm

        Height

        77 mm

        Width

        45 mm

        Depth

        84 mm

        Net weight

        0.58 kg

        Standards

      • BS 4794
      • EN 60947-5
      • IEC 60947-5-1
      • NF C 63-140
      • VDE 0660
        • Product certifications

        • UL
        • CSA
          • IP degree of protection

            IP2x front face conforming to VDE 0106

            Ambient air temperature for operation

          • -40-60 °C
          • 60-70 °C with derating
            • Ambient air temperature for storage

              -60-80 °C

              REACh Regulation

              Free of Substances of Very High Concern above the threshold

              EU RoHS Directive

              Compliant

              Mercury free

              Yes

              RoHS exemption information

              Yes

              China RoHS Regulation

              Product out of China RoHS scope. Substance declaration for your information

              California proposition 65

              WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov

              Others

              Product name

              TeSys CAD

              Device short name

              CAD

              Contactor application

              control circuit

              Utilisation category

            • AC-15
            • AC-14
            • DC-13
              • Pole contact composition

                5 NO

                Control circuit type

                AC at 50/60 Hz

                [Uc] control circuit voltage

                500 V AC 50/60 Hz

                [Uimp] rated impulse withstand voltage

                6 kV conforming to IEC 60947

                [Ith] conventional free air thermal current

                10 A (at 60 °C)

                Irms rated making capacity

              • 140 A AC conforming to IEC 60947-5-1
              • 250 A DC conforming to IEC 60947-5-1
                • [Icw] rated short-time withstand current

                • 100 A - 1 s
                • 120 A - 500 ms
                • 140 A - 100 ms
                  • Associated fuse rating

                    10 A gG conforming to IEC 60947-5-1

                    [Ui] rated insulation voltage

                  • 600 V UL certified
                  • 600 V CSA certified
                  • 690 V conforming to IEC 60947-5-1
                    • Tightening torque

                    • 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2
                    • 1.2 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
                      • Control circuit voltage limits

                      • 0.3...0.6 Uc (-40-70 °C):drop-out AC 50/60 Hz
                      • 0.8...1.1 Uc (-40-60 °C):operational AC 50 Hz
                      • 0.85...1.1 Uc (-40-60 °C):operational AC 60 Hz
                      • 1...1.1 Uc (60-70 °C):operational AC 50/60 Hz
                        • Operating time

                        • 12...22 ms coil energisation and NO closing
                        • 4...12 ms coil de-energisation and NO opening
                          • Maximum operating rate

                            180 cyc/mn

                            Inrush power in VA

                            70-70 VA 50 Hz (at 20 °C)

                            Hold-in power consumption in VA

                            8-8 VA 50 Hz (at 20 °C)

                            Minimum switching voltage

                            17 V

                            Minimum switching current

                            5 mA

                            Non-overlap time

                          • 1.5 ms on energisation between NC and NO contact
                          • 1.5 ms on de-energisation between NC and NO contact
                            • Mechanical robustness

                            • shocks control relay open: 10 Gn for 11 ms conforming to IEC 60068-2-27
                            • shocks control relay closed: 15 Gn for 11 ms conforming to IEC 60068-2-27
                            • vibrations control relay open: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
                            • vibrations control relay closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6
                              • Compatibility code

                                CAD

                                Protective treatment

                                TH conforming to IEC 60068

                                Operating altitude

                                0...3000 m

                                Unit Type of Package 1

                                PCE

                                Number of Units in Package 1

                                1

                                Package 1 Weight

                                300 g

                                Package 1 Height

                                9.4 cm

                                Package 1 width

                                8.1 cm

                                Package 1 Length

                                5.4 cm

                                WEEE

                                The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
                                Show all specifications