Specifications

Design

Range of product

TeSys D control relay

Range

TeSys

Product or component type

control relay

Warranty

18 months

Physical

[Ue] rated operational voltage

<= 690 V AC 25...400 Hz

Mounting support

  • rail
  • plate
    • Connections - terminals

    • screw clamp terminals 1 cable(s) 1-4 mm²flexible without cable end
    • screw clamp terminals 2 cable(s) 1-4 mm²flexible without cable end
    • screw clamp terminals 1 cable(s) 1-4 mm²flexible with cable end
    • screw clamp terminals 2 cable(s) 1-2.5 mm²flexible with cable end
    • screw clamp terminals 1 cable(s) 1-4 mm²solid without cable end
    • screw clamp terminals 2 cable(s) 1-4 mm²solid without cable end
      • Mechanical durability

        30 Mcycles

        Insulation resistance

        > 10 MOhm

        Height

        77 mm

        Width

        45 mm

        Depth

        93 mm

        Net weight

        0.58 kg

        Standards

      • BS 4794
      • EN 60947-5
      • IEC 60947-5-1
      • NF C 63-140
      • VDE 0660
        • Product certifications

        • CSA
        • UL
          • IP degree of protection

            IP2x conforming to VDE 0106

            Ambient air temperature for operation

          • -40-60 °C
          • 60-70 °C with derating
            • Ambient air temperature for storage

              -60-80 °C

              REACh Regulation

              Free of Substances of Very High Concern above the threshold

              EU RoHS Directive

              Compliant

              Mercury free

              Yes

              RoHS exemption information

              Yes

              China RoHS Regulation

              Product out of China RoHS scope. Substance declaration for your information

              California proposition 65

              WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov

              Others

              Number of Units in Package 1

              1

              Package 1 Height

              5.2 cm

              Package 1 Length

              11.2 cm

              Package 1 width

              9.2 cm

              Unit Type of Package 1

              PCE

              Product name

              TeSys CAD

              Device short name

              CAD

              Contactor application

              control circuit

              Utilisation category

            • AC-15
            • AC-14
            • DC-13
              • Pole contact composition

                5 NO

                Control circuit type

                DC low consumption

                [Uc] control circuit voltage

                24 V DC

                [Uimp] rated impulse withstand voltage

                6 kV conforming to IEC 60947

                [Ith] conventional free air thermal current

                10 A (at 60 °C)

                Irms rated making capacity

              • 140 A AC conforming to IEC 60947-5-1
              • 250 A DC conforming to IEC 60947-5-1
                • [Icw] rated short-time withstand current

                • 100 A - 1 s
                • 120 A - 500 ms
                • 140 A - 100 ms
                  • Associated fuse rating

                    10 A gG conforming to IEC 60947-5-1

                    [Ui] rated insulation voltage

                  • 600 V UL certified
                  • 600 V CSA certified
                  • 690 V conforming to IEC 60947-5-1
                    • Tightening torque

                    • 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2
                    • 1.2 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
                      • Control circuit voltage limits

                      • 0.1...0.25 Uc (-40-70 °C):drop-out DC
                      • 0.7...1.25 Uc (-40-60 °C):operational DC
                      • 1...1.25 Uc (60-70 °C):operational DC
                        • Operating time

                        • 65...88 ms coil energisation and NO closing
                        • 14...25 ms coil de-energisation and NO opening
                          • Maximum operating rate

                            180 cyc/mn

                            Time constant

                            40 ms

                            Inrush power in W

                            2.4-2.4 W (at 20 °C)

                            Hold-in power consumption in W

                            2.4-2.4 W at 20 °C

                            Minimum switching voltage

                            17 V

                            Minimum switching current

                            5 mA

                            Non-overlap time

                          • 1.5 ms on energisation between NC and NO contact
                          • 1.5 ms on de-energisation between NC and NO contact
                            • Mechanical robustness

                            • shocks control relay open: 10 Gn for 11 ms conforming to IEC 60068-2-27
                            • shocks control relay closed: 15 Gn for 11 ms conforming to IEC 60068-2-27
                            • vibrations control relay open: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
                            • vibrations control relay closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6
                              • Compatibility code

                                CAD

                                Protective treatment

                                TH conforming to IEC 60068

                                Operating altitude

                                0...3000 m

                                Package 1 Weight

                                531 g

                                WEEE

                                The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
                                Show all specifications

                                Frequently Asked Questions

                                hide show

                                What the DC current contact ratings for the CAD50, CAD32, CAD503, CAD323, CAD506, and CAD326 relay?

                                Issue:
                                Checking on the DC current contact ratings for the CAD50, CAD32, CAD503,  CAD323,  CAD506, and  CAD326 relay.

                                Product Line:
                                CAD Industrial Relays

                                Environment:
                                Relays and Timers

                                Resolution:
                                Inductive:
                                125V DC - 0.55 Amps make and break, 2.5 Amps cont.
                                250V DC - 0.27 Amps make and break, 2.5 amps cont.
                                600V DC - 0.10 Amps make and break, 2.5 Amps cont.

                                What is the replacement code for CA2DN40U5

                                The replacement part code is CAD50U7

                                What is the rating for a CAD50U7

                                 The rating is 10A

                                Is the coil on CAD50BL polarity sensitive?

                                Issue:
                                What is the hot and neutral on the coil terminals for CAD50BL?

                                Product Line:
                                Industrial Relays

                                Environment:
                                Tesys D IEC Style Relays

                                Cause:
                                Determine if relay will work for a specific application.                                     

                                Resolution:                                                                 
                                Yes, the DC coil is polarity sensitive - A1 is positive and A2 is negative.

                                What is the replacement AC coil for CAD32 and CAD50 relay?

                                Issue:
                                AC coil replacement for CAD32 and CAD50

                                Product Line:
                                Relays

                                Environment:
                                Tesys CAD Control Relays

                                Cause:
                                Product selection

                                Resolution:
                                Volt = coil part number
                                12 = LXD1J7
                                21 = LXD1Z7
                                24 = LXD1B7
                                32 = LXD1C7
                                36 = LXD1CC7
                                42 = LXD1D7
                                48 = LXD1E7
                                60 = LXD1EE7
                                100 = LXD1K7
                                110 = LXD1F7
                                115 = LXD1FE7
                                120 = LXD1G7
                                127 = LXD1FC7
                                200 = LXD1L7
                                208 = LXD1LL7
                                220/230 = LXD1M7
                                230 595 21 LXD1P7
                                230/240 = LXD1U7
                                277 781 30 LXD1W7
                                380/400 = LXD1Q7
                                400 = LXD1V7
                                415 = LXD1N7
                                440 = LXD1R7
                                480 = LXD1T7
                                600 = LXD1X7
                                690 = LXD1Y7

                                 

                                What safety category rating do the CAD TeSys relays meet under IEC EN954-1? Do they have linked contacts?

                                Issue:
                                Safety category listing of CAD TeSys relays

                                Product Line:
                                Relays

                                Environment:
                                TeSys D Relays

                                Resolution:
                                ​The Tesys CAD32** and the CAD50** relays and top mounted adder decks have positively guided or linked contacts.  Therefore the contacts meet IEC EN60947-5-1 and are approved to use in safety systems through category 4.