Quantcast

Blue Point Fused Terminal Blocks, 250V, 2A, Fuse

Blue Point Fused Terminal Blocks, 250V, 2A, Fuse

Blue Point Fused Terminal Blocks, 250V, 2A, Fuse

Item Number: BPF2

Retail
$8.61
RRP (Inc. GST)

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Product brand

Clipsal

Physical

Length

25 mm

[Ue] rated operational voltage

250 V AC

[In] rated current

2 A

EU RoHS Directive

Under investigation

Others

Diameter

6 mm

Unit Type of Package 1

PCE

Number of Units in Package 1

1

Package 1 Weight

2 g

Package 1 Height

6 mm

Package 1 width

6 mm

Package 1 Length

25 mm
Show all specifications

Frequently Asked Questions

hide show

What are the Clipsal BPT2 Dimensions?

  • Dimensions: 58 x 40 x 40 mm
https://www.clipsal.com/Trade/Products/ProductDetail?CatNo=BPT2

What is a bPF fault on the ATS22 soft starter?

Issue:
bPF fault on the ATS22.

Product Line:
Altistart ATS22

Environment:
All

Cause:
Bypass contactor detected fault

Resolution:
Check for a welded bypass contactor or shorted SCR.
If you find a shorted SCR or bypass contactor, you will need to replace the soft starter.
Reference the ATS22 installation guide (BBV51330)

What is BPFE Function used for in the NT-NW circuit breaker?

Basically, BPFE is an another check point to close the circuit remotely. 

With the BPFE option the customer can control the device electrically in order to close it.
When we say "control", it means that if all the safety conditions (part of the customer control/monitoring system of the installation) are enabled, the customer control/monitoring system of the installation will energize the XF through the wiring A3-A1. But at this step is not enough to close the breaker.  The engineer present in front of the device must press the BPFE button in order to close the device, if they consider no visual risk present before closing the device.

 

What would cause an EPF2 fault on the ATV61 drive with an Ethernet IP card?

Issue: 
What would cause an EPF2 fault on the ATV61 drive with an Ethernet IP card?

Product Line:
Altivar ATV61

Environment:
All

Cause:
Using an Allen Bradley PLC trying to access assemblies 103 and 104, and the drive has not been set up per case 2 example as recommended in the Ethernet IP VW3A3316 manual.

Resolution:
Case 2 programming example is as follows:

  • Menu 1.6
  • Ref 1= Communications card
  • Profile= Separate controls
  • CMD switching= C312
  • CMD channel 1= Communication card
  • CMD channel 2= Terminal control
  • Ref 2 Switching= C313
  • Ref 2 Channel= AI1 or AI2

What will cause EPF2 fault on ATV32 when talking Ethernet?

Issue:
EPF2 fault on ATV32 when using Ethernet.

Product Line:
ATV32/ATV320

Environment:
All

Cause:
FDR detected fault
IP address duplication detected fault

Resolution:
First check the FDR on the Ethernet IP card is disabled. In case the FDR is enabled, that will explain the "EPF2" fault. The reason is that the Drive is waiting for a configuration from PLC but PLC don't answer once the timeout is reached. This causes the drive to trip in "EPF2".
The second reason for "EPF2" fault is the range of IP address. In case of IP address 192.0.0.x and Sub net mask of 255.255.255.0 can cause "EPF2". Change the range of IP address.

What would cause a EPF2 fault using Profinet's telegram 1 and I/O profile on the ATV630 and ATV930 drives?

Issue:
EPF2 fault causes using Profinet and I/O profile on the ATV630 and ATV930 drives.

Product Line:
ATV630, ATV930

Environment:
All

Cause:
IO Profile and Telegram 1 are not compatible. 

Resolution:
Profinet telegram 1 is not supported with IO Profile.  It is suggested that they use telegram 100 which does support IO Profile.
Show More