What is the din rail mounting kit part number for the ATV312?
Issue:
Part number for ATV312 Din rail mounting kit
Product Line:
ATV312
Environment:
All
Cause:
Desire to utilize din mounting kit option
Resolution:
The part numbers need to order the mounting kit for this drive are VW3A9804 and VW3A9805.
VW3A9804 covers the following range of drives: ATV312....
018M2, H037M2, H055M2, H075M2, H018M3, H037M3, H055M3, H075M3
VW3A9805 covers the following range of drives: ATV312....
HU11M2, HU15M2, HU11M3, HU15M3, HU22M3, H037N4, H055N4, H075N4, HU11N4, HU15N4, H075S6, HU15S6
Note: The din rail mounting kits are only available for the above drives.
Note: Other drives not list above do not have a din rail kit.
Can the ATV312 be powered by an external 24V only?
Issue:
Powering the ATV312 by an external 24Vdc only
Product Line:
Altivar 312
Environment:
All
Cause:
Installation/programming
Resolution:
No, this drive must have line voltage applied. The voltage must be within -15% to +10% of the rated line voltage.
Are drive thermal output ratings available in BTU?
Issue:
Are drive thermal output ratings available in BTU?
Product Line:
Altivar Machines
Environment:
All
Cause:
Documentation
Resolution:
Heat dissipation is listed in Watts only.
See the drive catalog or installation guide for details on the heat dissipation.
1 watt is approximately 3.41 BTU/h
1000 BTU/h is approximately 293 W
When do the cooling fans on the ATV212 drives come on?
Issue:
Wondering when the cooling fans on the ATV212 drives come on?
Product Line:
Altivar 212
Environment:
All
Cause:
Fan control strategy
Resolution:
The fan starts when the drive is in RUN state.
The fan stops after the STOP command (with a time delay in relation to the thermal state).
What is the part number for the conduit entry kit for the ATV312HU11M2, ATV312HU15M2, ATV312HU22M3, ATV312H037N4, ATV312H055N4, ATV312H075N4, ATV312HU11N4, ATV312HU15N4, ATV312H075S6 or ATV312HU15S6?
Issue:
Part number for the conduit entry kit for the ATV312HU11M2, ATV312HU15M2, ATV312HU22M3, ATV312H037N4, ATV312H055N4, ATV312H075N4, ATV312HU11N4, ATV312HU15N4, ATV312H075S6 or ATV312HU15S6?
Product Line:
ATV312
Environment:
ATV312HU11M2, ATV312HU15M2, ATV312HU22M3, ATV312H037N4, ATV312H055N4, ATV312H075N4, ATV312HU11N4, ATV312HU15N4, ATV312H075S6 or ATV312HU15S6
Cause:
Conduit entry kit
Resolution:
The Conduit entry kit part number is the VW3A31814.