Quantcast

Altistart 22 Soft Starter ATS22 Control, 220V Power 230V(90kW)/400...440V(160kW)

Altistart 22 Soft Starter ATS22 Control, 220V Power 230V(90kW)/400...440V(160kW)

Altistart 22 Soft Starter ATS22 Control, 220V Power 230V(90kW)/400...440V(160kW)

Item Number: ATS22C32Q

Retail
$9,211.72
RRP (Inc. GST)

Product Dimensions

Width icon

Width206 mm

Height icon

Height425 mm

Depth icon

Depth299 mm

See full specifications

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range of product

Altistart 22

Product or component type

soft starter

Product destination

asynchronous motors

Sustainable offer status

Green Premium product

Warranty

18 months

Physical

IP degree of protection

IP00

Function available

internal bypass

Output current

0.4...1 Icl adjustable

Communication port protocol

Modbus

Connector type

1 RJ45

Protection type

  • phase failure: line
  • thermal protection: motor
  • thermal protection: starter
    • Marking

      CE

      Height

      425 mm

      Width

      206 mm

      Depth

      299 mm

      Net weight

      33 kg

      Standards

      EN/IEC 60947-4-2

      Product certifications

    • UL
    • CCC
    • C-Tick
    • CSA
    • GOST
      • Relative humidity

        0-95 % without condensation or dripping water conforming to EN/IEC 60068-2-3

        Ambient air temperature for operation

      • -10-40 °C (without derating)
      • 40-60 °C (with current derating 2.2 % per °C)
        • Ambient air temperature for storage

          -25-70 °C

          REACh Regulation

          Free of Substances of Very High Concern above the threshold

          EU RoHS Directive

          Pro-active compliance (Product out of EU RoHS legal scope)

          Mercury free

          Yes

          RoHS exemption information

          Yes

          China RoHS Regulation

          X

          Environmental Disclosure

          ENVPEP100402EN

          Circularity Profile

          ENVEOLI110805EN

          California proposition 65

          WARNING: This product can expose you to chemicals including: Lead and lead compounds which is known to the State of California to cause Carcinogen & Reproductive harm. For more information go to www.p65warnings.ca.gov

          Others

          Product specific application

          pumps and fans

          Component name

          ATS22

          Network number of phases

          3 phases

          [Us] rated supply voltage

          230...440 V - 15...10 %

          Motor power kW

        • 160 kW 400 V
        • 160 kW 440 V
        • 90 kW 230 V
          • Factory setting current

            285 A

            Power dissipation in W

            150 W for standard applications

            Utilisation category

            AC-53A

            Type of start

            start with torque control (current limited to 3.5 In)

            IcL starter rating

            320 A for connection in the motor supply line for standard applications

            Assembly style

            with heat sink

            Supply voltage limits

            195-484 V

            Supply frequency

            50...60 Hz - 10...10 %

            Network frequency

            45...66 Hz

            Device connection

          • to the motor delta terminals
          • in the motor supply line
            • [Uc] control circuit voltage

              230 V - 15...10 % 50/60 Hz

              Control circuit consumption

              20 W

              Discrete output number

              2

              Discrete output type

            • relay outputs R1 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O
            • relay outputs R2 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O
              • Minimum switching current

                100 mA at 12 V DC (relay outputs)

                Maximum switching current

              • 5 A 250 V AC resistive 1 relay outputs
              • 5 A 30 V DC resistive 1 relay outputs
              • 2 A 250 V AC inductive 0.4 20 ms relay outputs
              • 2 A 30 V DC inductive 7 ms relay outputs
                • Discrete input number

                  3

                  Discrete input type

                  (LI1, LI2, LI3) logic, 5 mA 4.3 kOhm

                  Discrete input voltage

                  24 V <= 30 V

                  Discrete input logic

                  positive logic LI1, LI2, LI3 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA

                  PTC probe input

                  750 Ohm

                  Communication data link

                  serial

                  Physical interface

                  RS485 multidrop

                  Transmission rate

                  4800, 9600 or 19200 bps

                  Installed device

                  31

                  Type of cooling

                  forced convection

                  Operating position

                  vertical +/- 10 degree

                  Power range

                • 55-100 kW at 200-240 V 3 phases
                • 110-220 kW at 380-440 V 3 phases
                  • Motor starter type

                    soft starter

                    Electromagnetic compatibility

                  • conducted and radiated emissions level A conforming to IEC 60947-4-2
                  • damped oscillating waves level 3 conforming to IEC 61000-4-12
                  • electrostatic discharge level 3 conforming to IEC 61000-4-2
                  • immunity to electrical transients level 4 conforming to IEC 61000-4-4
                  • immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3
                  • voltage/current impulse level 3 conforming to IEC 61000-4-5
                    • Vibration resistance

                    • 1 gn (f= 13-200 Hz) conforming to EN/IEC 60068-2-6
                    • 1.5 mm (f= 2-13 Hz) conforming to EN/IEC 60068-2-6
                      • Shock resistance

                        15 gn for 11 ms conforming to EN/IEC 60068-2-27

                        Noise level

                        56 dB

                        Pollution degree

                        level 2 conforming to IEC 60664-1

                        Operating altitude

                      • <= 1000 m without derating
                      • > 1000...< 2000 m with current derating of 2.2 % per additional 100 m
                        • Package 1 Weight

                          24.5 kg

                          Package 1 Height

                          4.9 dm

                          Package 1 width

                          3.65 dm

                          Package 1 Length

                          5.45 dm

                          WEEE

                          The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
                          Show all specifications

                          Frequently Asked Questions

                          hide show

                          What are the dimensions for the VW3G48101, remote keypad for the ATS48?

                          Issue:
                          ATS48 remote keypad dimensions.

                          Product Line:
                          Altistart 48

                          Environment:
                          All

                          Cause:
                          N/A

                          Resolution:
                          Remote keypad part# VW3G48101
                          Width = 2 5/8 inches
                          Height = 4 1/4 inches
                          Depth = 5/8 inches
                          This includes a clear membrane cover and a trim bezel.

                          What are the minimum required clearances for the ATS48 unit for enclosure mounting?

                          Issue:
                          Minimum clearances required on the ATS48 soft starters?

                          Product line:
                          Altistart 48, ATS48

                          Environment:
                          all

                          Cause:
                          Mounting inside an enclosure

                          Resolution:
                          There is a minimum of 4 inches (100 mm) on the top and bottom of the softstart. A minimum clearance of 2 inches (50mm) on each sides.
                          The enclosure must also allow for proper ventilation to maintain a temperature of 40C (104F) and required wire bending space.

                          Can the operating time be reset to zero on the Altistart ATS48?

                          Issue:
                          Needs to reset the operating time to zero on the ATS48.

                          Product line:
                          Altistart 48, softstart

                          Environment:
                          all

                          Cause:
                          Reset operating time

                          Resolution:
                          Yes.  Can go into the dRc menu and in the rPr parameter:  The options available here are:

                          - no: function inactive
                          - APH: kWh reset to zero
                          - trE: operating time reset to zero

                          The reset command must be confirmed with ENT. APH and trE take effect immediately.
                          The parameter then automatically returns to no.
                           

                          Does the ATS48 unit provide separate power terminals to connect cables that feed the line side of the shorting contactor?


                          Issue:
                           Does the ATS48 unit provide separate power terminals to connect cables that feed the line side of the shorting contactor?

                          Product Line:
                          Altistart 48

                          Environment:
                          All models and serial numbers

                          Cause:
                          All ATS48 Soft Starts
                           
                          Resolution:
                          No.  None of the ATS48 units have separate terminals for the line side of the shorting contactor.  The ATS48 L1, L2, L3 terminals are for incoming line connections.  This may require that separate terminal blocks be used to connect the line side of the shorting (bypass) contactor.
                          Note:  There are contactor load terminals provided for A2, B2, C2.

                           

                          What are the dimensions of the Soft Starter part number ATS22D62Q?

                          The dimensions of the Soft Starter part number ATS22D62Q are as follows:

                          Height 295 mm
                          Width 145 mm
                          Depth 207 mm

                          https://www.schneider-electric.com.au/en/search/ATS22D62Q

                          What's the difference between ATS22..S6U and ATS22...S6 Softstart models?

                          Issue:
                          Differences between an ATS22..S6U and  ATS22..S6 soft start models.

                          Product Line:
                          Altistart 22 ATS22

                          Environment:
                          All models, All series

                          Cause: 
                          Altistart has difference voltage suffix S6U and S6.  

                          Resolution:
                          The ATS22..S6 model requires 220vac control power and has 24vdc logic inputs.





                          The ATS22..S6U model requires 110vac control power and has 110vac logic inputs.


                          Show More