Universal Power Supply 20A 3p

Phaseo Regulated SMPS, 3 Phase, 380..500VAC, 24V, 20A

Catalogue Number: ABL8WPS24200
Universal Power Supply 20A 3p
Colour:
Colour: Per UOM Std.
  • 1 PCE

Specifications

hide show
Range of product
Phaseo
Product or component type
power supply
Power supply type
regulated switch mode
Input voltage
380...500 V AC three phase, terminal(s): L1, L2, L3
Output voltage
24 V DC
Rated power in W
480 W
Provided equipment
power factor correction filter conforming to IEC 61000-3-2
Power supply output current
20 A
Output protection type
  • against overload, protection technology: manual or automatic reset
  • against overvoltage, protection technology: 30...32 V, manual reset
  • against short-circuits, protection technology: manual or automatic reset
  • against undervoltage, protection technology: tripping if U < 21.6 V
  • thermal, protection technology: automatic reset
    • Ambient air temperature for operation
    • 50-60 °C (with derating factor)
    • -25-50 °C (without)
      • Input voltage limits
        320...550 V
        Network frequency
        47...63 Hz
        Inrush current
        25 A 2 ms
        Cos phi
        0.65-0.65
        Efficiency
        92 %
        Output voltage limits
        24...28.8 V adjustable
        Power dissipation in W
        38.4 W
        Line and load regulation
        1...3 %
        Holding time
        >= 18 ms at 400 V
        Permissible temporary current boost
        1.5 x In (for 4 s)
        Connections - terminals
      • for diagnostic relay: removable screw terminal block, connection capacity: 2 x 2.5 mm²
      • for input connection: screw type terminals, connection capacity: 3 x 0.5...3 x 4 mm² AWG 22...AWG 12
      • for input ground connection: screw type terminals, connection capacity: 1 x 0.5...1 x 4 mm² AWG 22...AWG 12
      • for output connection: screw type terminals, connection capacity: 4 x 0.5...4 x 10 mm² AWG 22...AWG 8
        • Marking
          CE
          Mounting support
        • 35 x 7.5 mm symmetrical DIN rail
        • 35 x 15 mm symmetrical DIN rail
          • Operating position
            vertical
            Operating altitude
            2000 m
            Output coupling
          • series
          • parallel
            • Name of test
            • electrostatic discharges conforming to EN/IEC 61000-4-2
            • induced electromagnetic field conforming to EN/IEC 61000-4-6
            • magnetic field conforming to EN 61000-4-8
            • primary outage conforming to IEC 61000-4-11
            • radiated electromagnetic field conforming to EN/IEC 61000-4-3
            • rapid transient conforming to IEC 61000-4-4
            • surge conforming to EN/IEC 61000-4-5
            • conducted emissions on the power line conforming to EN 55022 class B
            • radiated emissions conforming to EN 55022 class B
            • harmonic current emission conforming to EN/IEC 61000-3-2
              • Status LED
              • 1 LED (green and red)output voltage:
              • 1 LED (green, red and orange)output current:
                • Depth
                  160 mm
                  Height
                  143 mm
                  Width
                  96 mm
                  Net weight
                  1.6 kg
                  Anti-harmonic filter
                  low frequency harmonic currents
                  Compatibility code
                  ABL8W
                  MTBF reliability
                • 691000 H at 320 V AC with UTE C80-810 calculation method
                • 670000 H at 550 V AC with UTE C80-810 calculation method
                  • Product certifications
                  • cCSAus
                  • EAC
                  • UL
                  • RCM
                    • Standards
                    • CSA C22.2 No 60950-1
                    • UL 508
                      • Environmental characteristic
                      • EMC conforming to EN 61000-6-1
                      • EMC conforming to EN 61000-6-3
                      • EMC conforming to EN 55024
                      • EMC conforming to EN/IEC 61000-6-4
                      • EMC conforming to EN/IEC 61204-3
                      • safety conforming to EN 61204-4
                      • safety conforming to EN/IEC 60950-1
                      • safety conforming to SELV
                        • IP degree of protection
                          IP20 conforming to EN/IEC 60529
                          Ambient air temperature for storage
                          -40-70 °C
                          Relative humidity
                        • 0-90 % during operation
                        • 0-95 % in storage
                          • Overvoltage category
                            class I conforming to VDE 0106-1
                            Dielectric strength
                          • 3500 V between input and ground
                          • 4000 V between input and output
                          • 500 V between output and ground
                            • Sustainable offer status
                              Green Premium product
                              REACh Regulation
                              Free of Substances of Very High Concern above the threshold
                              EU RoHS Directive
                              Pro-active compliance (Product out of EU RoHS legal scope)
                              Mercury free
                              Yes
                              RoHS exemption information
                              Yes
                              China RoHS Regulation
                              X
                              Environmental Disclosure
                              ENVPEP061202EN
                              Circularity Profile
                              ENVEOLI0612002EN
                              California proposition 65
                              WARNING: This product can expose you to chemicals including: Lead and lead compounds which is known to the State of California to cause Carcinogen & Reproductive harm. For more information go to www.p65warnings.ca.gov
                              Warranty
                              18 months

                              Documents & downloads

                              hide show
                              Filter items
                              • All

                              • CAD Files and Packs

                              • Product Brochures

                              • Technical Data Catalogues

                              • Installation Instruction

                              • End of Life Manual

                              • Product Environmental

                              • Data Bulletin

                              • Handout

                              • Operating Manuals

                              • eTechPub

                              • Certificates (MSDS)

                              • Declaration of Conformity

                              Frequently Asked Questions

                              hide show

                              What is the operating temperature range on the ABL8WPS24200 and ABL8WPS24400 power supplies?

                              Issue:
                              Needs environmental data for ABL8WPS24200 and ABL8WPS24400.

                              Product Line:
                              ABL8WPS24200 and ABL8WPS24400

                              Environment:
                              ABL Power Supplies
                               
                              Resolution:
                              Per expanded catalog DIA3ED207041EN-US, page 30 "-13°F to 140°F with derating from 122 °F or  (-25 to +60 derating from 50°C)"

                              What is the replacement for a ABL8WPS24200

                              Use a ABL4WSR24200.

                              What is the replacement for ABL4RPM24100?

                              ABL8RPS24100

                              What is the mean time between failures (MTBF) for ABL8RPM24200?

                              The 2 MTBF values for ABL8RPM24200 are;

                              • 717000h for 100Vac
                              • 695000h for 240Vac

                               
                               
                               
                               

                              What is the alternative for ABL4RSM24100 Power Supply ?

                              Code = ABL8RPS24100
                               

                              What is the alternate code for a ABL7RE2410

                              End of life 30/03/2008. Use a ABL8RPS24100.

                              Is the ABL8RPS24030 okay for 60 hertz?

                              Yes they are have a Network Frequency range of 47 - 63 Hz
                              As shown on attached Data sheet

                              What is the alternative for ABL4RSM24200?

                              The alternative for ABL4RSM24200 is ABL4RSM24200.
                              Please see below for a comparison:

                              ABL 8RPM24200
                                Width: 145mm
                              ABL 4RSM24200  Width: 80mm

                              Installation differences :
                              ●Input and output terminals reversed
                              ●120/230 V voltage selection
                              ●ABL4: by link
                              ●ABL8: by terminal

                              ABL4 does not conform to IEC 61000-3-2 (1) Resetting of protection:
                              ●ABL4: automatic
                              ●ABL8: selectable, automatic or manual

                              For further information please visit www.schneider-electric.com.au
                              Or see attached PDF.

                              What is the replacement power supply for the ABl7RE2410

                              The part code ABL4RSM24100

                              What is the dimensions ABL4RSM24100

                               The dimensions 63 x 140 x 118mm

                              What is the dimensions ABL4RSM24100

                               The dimensions 63 x 140 x 118mm

                              What are the dimensions for ABL8REM24050

                               Dimensions 54 wide x 120 high x 120mm deep to the din rail face

                              Is part code ABL7RE24025 still available in NZ

                               Part code ABL7RE24025 discontinued 30/03/2008.  You can use a ABL8REM24050

                              What is the maximum amount of Phaseo power supplies that can be paralleled together?

                              The Maximum power supplies that be coupled together is two devices.
                              The potential voltage needs to be equal before connecting together.

                               

                              Will the Compact NSX breaker be for sale in the USA or Canada?

                              Issue:
                              Where can I buy a Compact NSX breaker?

                              Product Line:
                              Circuit Breakers

                              Cause:
                              This breaker is popular overseas and there is interest in the US

                              Resolution:
                              There are no plans for a general release of the Compact NSX breaker line in North America, since the NSX is not UL Listed to UL489. (UL 489 is the standard commonly required in the US.) In the US, the Powerpact Circuit Breakers should be used (Powerpact breakers are UL, CSA and IEC-rated).

                              If an existing piece of equipment has an NSX breaker which needs replacing, we have made a few catalog numbers available for sale in the US. The list of numbers will vary based upon need. Contact your local authorized Schneider Electric distributor for assistance on your specific NSX catalog number.

                              For support on these breakers, Please see the following link to Global Operations where you can select other Countries:
                              https://www2.schneider-electric.com/sites/corporate/en/support/operations/local-operations/local-operations.page