Quantcast

StarServe Lite Enclosure, Surface Mount (330 x 210 x 130mm)

StarServe Lite Enclosure, Surface Mount (330 x 210 x 130mm)

StarServe Lite Enclosure, Surface Mount (330 x 210 x 130mm)

Item Number: 8000LEN

Retail
$297.10
RRP (Inc. GST)

Product Dimensions

Width icon

Width200 mm

Height icon

Height300 mm

Depth icon

Depth145 mm

See full specifications

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Product brand

Clipsal

Physical

Width

200 mm

Height

300 mm

Depth

145 mm

EU RoHS Directive

Under investigation

Others

Unit Type of Package 1

PCE

Number of Units in Package 1

1

Package 1 Weight

2.721 kg

Package 1 Height

15 cm

Package 1 width

37 cm

Package 1 Length

22.5 cm
Show all specifications

Frequently Asked Questions

hide show

Is there a flush version of StarServe lite enclosure 8000LEN?

For a flush StarServe lite enclosure, surface mount enclosure 8000LEN and the flush mounting kit 8000LENFK to suit 8000LEN are needed.
For further information please visit:
https://www.clipsal.com/Trade/Products/ProductDetail?catno=8000LENFK
https://www.clipsal.com/Trade/Products/ProductDetail?catno=8000LEN
8000LEN
8000LEN

What are the kind of Starserve enclosures are there?

Please see the Following table for StarServe Enclosures:
 
Part Number Description Dimensions
3105ABEN Slimline Plastic Enclosure 269mm(W) X 383mm(H) X 84mm(D)
3105PEN7440 ABS Plastic Enclosure - Suited for NBN 405mm(W) X 750mm(H) X 150mm(D)
8000LEN
Lite-Size Metal Enclosure
200mm(W) X 300mm(H) X 145(D)
8000LFK
8000LEN Enclosure Flush Kit
 
3105PENF Professional Metal Enclosure, Flush Mount 465mm(W) X 895mm(H) X 113mm(D)
8000MEN Mid-Size Metal Enclosure 415mm(W) 450mm(H) X 145mm(D)
8000MENFK
8000MEN Enclosure Flush Kit
 
3105PENS Professional Metal Enclosure, Surface Mount 465mm(W) X 895mm(H) X 113mm(D)
 
For Further information please visit www.clipsal.com/Trade/search-results?q=starserve
 
 
8000MEN

3105PENS
 8000LEN

3105PENF


3105PEN7440

3105ABEN

 

Is there a replacement for the 8000PEN?

Yes.
Flush Version - 3105PENF
Surface Version - 3105PENS
 

Is part numner 8000PKES still available?

No. Unfortunately, part is no longer available.

Replaced with 3105ABEN (Enclosure),3105SPF2(TV Splitter),3105APP8H6(Data Panel)
3105APP8/6(Phone Panel),3105VDU38IR(Video Distribution Hub) & RJ5/05PL-BU(Patch Leads)

Setting a controllers TOD (time of day clock) with Concept IEC logic.

Goals and Symptoms

The attached code shows an example of how to set the controllers TOD with IEC FBD logic.

Causes and Fixes

 

Step
Action
Description
1
Write a value of 0000H to the TOD control register This stops the clock.
2
Write the new TOD data to the clock registers These are the values the clock will start from when the final command is processed.
3
Write a value of 8000H to the TOD control register This commands the TOD to read in the new values. Once the PLC is finished reading in the new data, the register will return a value of 2000H.
4
Write a value of 4000H to the TOD command register This starts the clock. Once running, the TOD registers will be updating and the TOD command register will return a value of 6000H.

The steps above must be done one per scan so the solve order in the example code is important for this function.




The controllers TOD clock is set to start at register 400001.


Step #1:

The operation is initiate by setting Boolean Stop_Clock to rising edge 1.
The variable Stop_Code (0000Hex) is sent to the TOD control register thus stopping the clock.
Setting rising edge Boolean Set_Time to 1.

Step#2

From the previous step Set_Time is a logical one, thus enabling all of the MOVE blocks which contain the desired replacement time values.

The last MOVE block triggers a rising edge READ_CLOCK sending READ_CODE 8000Hex to the TOD control register.

Step#3
The next scan Start_Code 4000Hex is sent to the TOD control register starting the clock with the previously loaded replacement time values.

Legacy KB System (APS) Data: RESL169004 V1.0, Originally authored by on , Last Edited by on
Related ranges: Concept

How to enable 100ms Frequency monitoring on a CM4000 series meter

Issue
Enabling 100ms frequency monitoring on a CM4000

Product Line
CM4000

Environment
High Speed Monitoring

Cause
By default 100ms frequency monitoring is not enabled

Resolution
100ms Frequency monitoring is disabled by default on the CM4000 series meters. To enable this feature, the following command writes must be executed to the meter:

Write 9020 to register 8000
Write 11 to register 3239
Write 1 to register 8001
Write 9021 to register 8000

This will enable 100ms Frequency monitoring. The value is stored in register 1080 (Units - 0.01 Hz).