Quantcast

C-Bus DIN Rail Mounted DALI Gateway for 2 Dali Networks

C-Bus DIN Rail Mounted DALI Gateway for 2 Dali Networks

C-Bus DIN Rail Mounted DALI Gateway for 2 Dali Networks

Item Number: 5502DAL

Retail
$749.32
RRP (Inc. GST)

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range of product

C-Bus

Range

C-Bus

Product brand

Clipsal

Product or component type

gateway

Device application

communication

Sustainable offer status

Green Premium product

Physical

Local signalling

LED

Mounting support

DIN rail

REACh Regulation

Free of Substances of Very High Concern above the threshold

REACh free of SVHC

Yes

EU RoHS Directive

Compliant

Toxic heavy metal free

Yes

Mercury free

Yes

RoHS exemption information

Yes

China RoHS Regulation

X

Environmental Disclosure

ENVPEP111268EN

Circularity Profile

ENVEOLI111254EN

Others

Number of modules

4

Unit Type of Package 1

PCE

Number of Units in Package 1

1

Package 1 Weight

307 g

Package 1 Height

10 cm

Package 1 width

11 cm

Package 1 Length

15.5 cm

WEEE

The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
Show all specifications

Documents & downloads

hide show
Filter items
  • All

  • Product Brochures

  • CAD Files and Packs

  • Technical Data Catalogues

  • Technical Leaflet

  • Installation Instruction

  • Operating Manuals

  • Specifications

  • Application Solutions

  • Corporate Marketing

  • Software - Release

  • Software - Archive

Frequently Asked Questions

hide show

What code is a power supply for a 5502DAL DALI gateway?

The part number for a power supply to power the DALI gateway is a 5500PS.
Some of the key features are:
  • 3,750 V RMS AC isolation mains/C-Bus
  • 3 Seconds Warm-up time
  • High efficiency switched mode power supply design
  • DIN Rail mounted

What is used as the C-Bus to Bacnet Gateway

The 5500NAC or 5500SHAC can be used as Bacnet gateway depending on the number of Bacnet points which are required.
The 5500NAC has 500 Bacnet Points and the 5500SHAC has 50 Bacnet points.
Bacnet is normally used by Building Management systems.

What are the minimum visualization requirements in C-Bus Automation Controllers

C-Bus Automation Controllers will require as a minimum 1 level and 1 plan which contains controllable components before that plan can be visualized. 

Plans containing controllable components will also need to have Show in PC/Tablet and/or Show in Smartphone visualization checked (enabled)
image.png

Note: when making any changes in the C-Bus Automation Controller - please ensure the sync project data button in the bottom right hand corner has been pressed to ensure that those changes have been applied to the run time environment. 

Where to set Port numbers using NAC or SHAC

Access “Configuration” window on the web browser, select “System”, select “Services” which will allow you access to “HTTP server settings”, this is where your ports can be set.

How to control RS-232 enabled devices with C-Bus Network Automation Controller – 5500NAC (5500SHAC)?

A Configuration Guide exist on the Exchange Community, see the link below or the attachment.

How to control RS-232 enabled devices with C-Bus Network Automation Controller – 5500NAC



 

What is the part number for a C-Bus MPM BACNET Gateway?

The C-Bus Automation Controller - 5500NAC is now the preferred gateway and replaces the MPM BACnet Gateway. 

The part number for the MPM C-Bus BACnet Gateway is GCR_MPM_AU31

See attached Technical Datasheet
 
Ordered via normal process, either customer care if you have a direct account or via wholesaler if you don’t have a direct account
 
 
Show More