Quantcast

Clipsal C-Bus Application Controller, SpaceLogic C-Bus 6DIN

Clipsal C-Bus Application Controller, SpaceLogic C-Bus 6DIN

Clipsal C-Bus Application Controller, SpaceLogic C-Bus 6DIN

Item Number: 5500AC2

Datasheet

Product Dimensions

Width icon

Width93 mm

Height icon

Height108 mm

Depth icon

Depth63 mm

Specifications

Design

Range

SpaceLogic C-Bus

Product or component type

logic controller

Market segment

  • residential
  • buildings

Sustainable offer status

Green Premium product

Physical

Communication port protocol

  • C-Bus RJ45 (4000 devices)
  • IP (Internet Protocol) RJ45
  • serial link terminal block RS232
  • BACnet IP RJ45 (50 devices)
  • Modbus RTU terminal block RS485 (10 devices)
  • Modbus TCP RJ45

Power consumption in W

2 W

Local signalling

  • LED (green/red) for power
  • LED (green/red) for status indication
  • LED (green) for relay output (REL)
  • LED (multi-colour) for input status
  • LED (multi-colour) for RS232 link activity
  • LED (multi-colour) for serial link communication (RS485, RX, TX)
  • LED (green) for C-Bus status
  • LED (green/yellow) for Ethernet link

Control type

  • local control
  • by web browser
  • remote control
  • RESET push-button cold restart
  • smartphone or tablet
  • RESET push-button
  • by touch panel

Function available

  • updateable software
  • visualisation

Connections - terminals

  • power supply: screw terminal 3 cable(s) 1.5-1.5 mm²
  • LED lamp: screw terminal 2 cable(s) 1.5-1.5 mm²
  • relay digital output: screw terminal 3 cable(s) 1.5-1.5 mm²
  • digital input: screw terminal 2 cable(s) 1.5-1.5 mm²
  • RS232 link: screw terminal 3 cable(s) 1.5-1.5 mm²
  • RS485 link: screw terminal 5 cable(s) 1.5-1.5 mm²

Mounting support

DIN rail

Height

108 mm

Width

93 mm

Depth

63 mm

Ambient air temperature for operation

-5...45 °C

Relative humidity

10...90 %

IP degree of protection

IP20

Standards

  • EN 55032: class A
  • EN 50491-5-2: class B
  • EN 55035

REACh Regulation

Reference contains Substances of Very High Concern above the threshold

EU RoHS Directive

Compliant

Mercury free

Yes

China RoHS Regulation

X

RoHS exemption information

Yes

Environmental Disclosure

ENVPEP2104025EN

Circularity Profile

ENVEOLI2104025EN

Others

Package 1 Bare Product Quantity

1

Product name

C-Bus Automation Controller

[Us] rated supply voltage

24 V DC

Port Ethernet

10BASE-T/100BASE-TX

Number of port

  • 1 USB 2.0 type A
  • 1 USB 1.1 type B
  • 1 RS232 (serial link)
  • 1 RS485 (Modbus)
  • 2 RJ45 (C-Bus)
  • 1 RJ45 (Ethernet)

Web services

web server

Number of inputs

1 dry contact

Input impedance

  • 2.2 kOhm closed
  • 6.9 kOhm opened

Number of outputs

1 relay changeover

Output voltage

  • 24 V DC 1 A for relay
  • 48 V AC 1 A for relay

Total number of 18 mm modules

6

Operating altitude

<= 2000="">

Unit Type of Package 1

PCE

Number of Units in Package 1

1

Package 1 Height

9.3 cm

Package 1 Width

6.3 cm

Package 1 Length

10.8 cm

Package 1 Weight

364.0 g

Unit Type of Package 2

CAR

Number of Units in Package 2

10

Package 2 Height

30.0 cm

Package 2 Width

30.0 cm

Package 2 Length

40.0 cm

Package 2 Weight

4330.0 g

Unit Type of Package 3

P12

Number of Units in Package 3

240

Package 3 Height

95.0 cm

Package 3 Width

80.0 cm

Package 3 Length

120.0 cm

Package 3 Weight

108.0 kg
Show all specifications

Frequently Asked Questions

hide show

What is the main update of the firmware (V 1.14.0) for SpaceLogic C-Bus Controllers NAC2 and AC2?

What is the main update of the firmware (V 1.14.0) for SpaceLogic C-Bus Controllers NAC2 and AC2?

The new firmware (version 1.14.0) for SpaceLogic C-Bus Controllers NAC2 and AC2 is available for download on se.com. and in Exchange Platforms

The new firmware version V1.14.0 is available for 5500NAC2, 5500AC2, 5500NAC, 5500SHAC, LSS5500NAC, LSS5500SHAC.

The main update of this new firmware release (V1.14.0) are:
  • Bug fixes: Scheduler issue observed in old firmware build V1.13.0.


Links for www.se.com page and Exchange to download the firmware and the related documents:

Download from SE website:
https://www.se.com/ww/en/product-range/2216-spacelogic-cbus-home-automation-system/?parent-subcategory-id=88010&filter=business-5-residential-and-small-business#software-and-firmware

Download from SE Ecoxpert:
https://ecoxpert.se.com/en/spacelogic-c-bus/software-and-firmware/software#tab/documents/downloadDocument/40003156
 

Where to download the firmware (V 1.13.0) for SpaceLogic C-Bus Controllers NAC and AC?

The new firmware (version 1.13.0) for SpaceLogic C-Bus Controllers NAC and AC is available for download on se.com. and in Exchange Platforms

The new firmware version V1.13.0 is available for 5500NAC2, 5500AC2, 5500NAC, 5500SHAC, LSS5500NAC, LSS5500SHAC.

The main features of this new firmware release  (V1.13.0) are:
 

  • Scheduler Enhancement
  • Error reporting application improvements
  • Bug fixes

Related documents can be downloaded along with the firmware file:
  • Release Notes for V1.13.0
  • User Manual update for firmware V1.13.0
Links for www.se.com page and Exchange to download the firmware and the related documents:
 
 
5500NAC2
SpaceLogic C-Bus Network Automation Controller
Commercialized
 
 
Se.com: Link   
 
Exchange:
Firmware download page link
 
Direct link to the firmware file
 
5500AC2
SpaceLogic C-Bus Application Controller
Commercialized
 
 
Se.com: Link 
 
Exchange:
Firmware download page link
 
Direct link to the firmware file
 
5500NAC
C-Bus Network Automation Controller
End of Commercial
 
 
Se.com:  Link   
 
Exchange:
Firmware download page link
 
Direct link to the firmware file
 
5500SHAC
Wiser for C-Bus Automation Controller
End of Commercial
 
 
Se.com: Link
 
 
Exchange:
Firmware download page link
 
Direct link to the firmware file



 

What is the latest firmware version for C-Bus 5500NAC, 550SHAC, 5500NAC2 and 5500AC2 Automation Controller?

What is the latest firmware version for C-Bus 5500NAC, 550SHAC, 5500NAC2 and 5500AC2 Automation Controller?

Their latest firmware version is 1.12.0 and released on 24/10/2022, they can be download from SE and SEecoxpert website.

C-Bus Firmware for 5500NAC2 Automation Controller V1.12.0
https://www.se.com/ww/en/download/document/5500NAC2_Firmware-V1.12.0/

C-Bus Firmware for 5500AC2 Automation Controller V1.12.0
https://www.se.com/ww/en/download/document/5500AC2_Firmware-V1.12.0/

C-Bus Firmware for 5500NAC Automation Controller V1.12.0
https://www.se.com/ww/en/download/document/5500NAC_Firmware-V1.12.0/

C-Bus Firmware for 5500SHAC Automation Controller V1.12.0
https://www.se.com/ww/en/download/document/5500SHAC_Firmware-V1.12.0/

 

How to download the firmware files from se.com (global page)?

First, you need to find the product page! I.e 5500NAC2

 

  1. Type in the commercial reference in the search bar, and once the product you are looking for pop-up, click on the product bar.

 5500NAC2 1

 

  1. Once on the product page, scroll down, pass Main Documents > Specifications > Documents, and reach the Software and Firmware section at the bottom.

 5500NAC2 2

 

  1. Select “Firmware” for the latest version in the Document type section, or if you are looking for previous firmware files, you can see them under “Firmware – History and others”.

 5500NAC2 3

  1. You can download the firmware, release notes, and user manual separately OR as a whole in zip format.

How to configure BACnet on 5500NAC/SHAC ?

 

Please see attached link to the manual. Attention to page (142-144)

https://updates.clipsal.com/ClipsalSoftwareDownload/mainsite/cis/technical/AutoController/5500NAC_5500SHAC_FW_v1.0_EN.pdf

 Automation Controller can act as a BACnet server only (not as a client)

1

2

3

4

5

6

7


 

How to config SE8350 or SE8650 for Modbus RS-485 communications to SpaceLogic C-Bus Automation Controllers

1) Enter the Setup screen
Enter the Setup screen
Note: password reset is not within the scope of this FAQ. If you are a Certified EcoStruxure Building Operations (BMS) Partner and require the password to be reset. Please contact Schneider Electric Technical Support for further assistance 

2) Select the Network option 
Select network settings

3) Select the Wire protocol option
Select Modbus option

4) Enter the Modbus settings 

Enter Modbus settings

5) Enter the Modbus COM address

Enter Modbus COM address

6) Select the Modbus Network units

Select Network units

7) Select the Modbus Baud rate

Setting Modbus Baud rate
NOTE: It is recommended to choose either 9600 or 19200 (default) baud rate as most Modbus devices are compatible with either of these two rates. 

8) Select the Modbus Parity

Setting Parity bit

9) Select the Return to Setup Screen (twice)
Show More