Quantcast

Standard Series, Mounting Block, 2 Gang, Square

White Electric | Standard Series, Mounting Block, 2 Gang, Square

Standard Series, Mounting Block, 2 Gang, Square

Item Number: 448-WE

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Product brand

Clipsal

Product or component type

mounting block

Sustainable offer status

Green Premium product

Physical

Fixing center

84 x 46 mm

Depth

28 mm

Length

120 mm

Width

120 mm

Number of gangs

2 gangs

REACh Regulation

Free of Substances of Very High Concern above the threshold

REACh free of SVHC

Yes

EU RoHS Directive

Pro-active compliance (Product out of EU RoHS legal scope)

Toxic heavy metal free

Yes

Mercury free

Yes

RoHS exemption information

Yes

China RoHS Regulation

 Pro-active China RoHS declaration (out of China RoHS legal scope)

Environmental Disclosure

ENVPEP110719EN

Material

Material

PC (polycarbonate)

Others

Package 1 Bare Product Quantity

1

Shape

square

Unit Type of Package 1

PCE

Number of Units in Package 1

1

Package 1 Height

2.9 cm

Package 1 Width

12 cm

Package 1 Length

12 cm

Package 1 Weight

129 g

Unit Type of Package 2

BB1

Number of Units in Package 2

5

Package 2 Height

12.6 cm

Package 2 Width

14.2 cm

Package 2 Length

15.6 cm

Package 2 Weight

0.944 kg

Unit Type of Package 3

CAR

Number of Units in Package 3

50

Package 3 Height

25.4 cm

Package 3 Width

34.8 cm

Package 3 Length

44.5 cm

Package 3 Weight

50 kg
Show all specifications

Frequently Asked Questions

hide show

How to configure a C-Bus Automation Controller to SE8350 or SE8650 Room Controller for Modbus RS-485 communications

Upon successful login to the C-Bus 5500NAC2 (Network Automation Controller) or 5500AC2 (Application Controller)

Setting Modbus RTU Settings
1) Select the Configurator option from the 5500NAC2 / 5500AC2 - start page 
2) Select the Modbus tab to display modbus devices, settings and options
3) Select the RTU Settings option in the bottom left corner
4) Check the RTU (serial) enabled option for an available RTU connection 
5) Set the port to /dev/RS485 
6) Set the baud rate to match baud rate set in SE8350 or SE8650 (possible options - 4800, 9600, 19200, 38400, 57600)
7) Set the parity bit to match parity set in SE8350 or SE8650 (possible options none (1 stop bit), odd, even, none (2 stop bit). 
8) Set duplex option to "half duplex"
9) Select the Save button to set the Modbus RTU Settings

example: 
RTU Settings Dialog

Scanning Modbus RTU for Devices
1) Select the RTU Scan option in the bottom left corner
2) Enter the Scan range start (COM address of first SE8350/8650 in daisy chain) 
3) Enter the Scan range end (COM address of last SE8360/8650 in daisy chain) 
4) Select the Save button to start RTU scan for modbus devices

example:
 
RTU Scan Dialog

5) From the RTU Scan results - check the add device option and specify the name, modbus profile (SE8300, SE8600 or SER8300 depending on series of SE Room Controller). 
Note: The SE8300 series profile covers the SE8350 room controllers, SE8600 series profile covers the SE8650 room controllers. 

example:
RTU Scan Result Dialog

6) Select the Save button to add the devices to the list of modbus devices

Adding User Parameter Objects - Needed for Modbus Mapping
1) Select the Objects tab from the configuration page tabs to display C-Bus Automation Controller objects
2) Select the Add New Object option in the bottom left corner to add a user parameter which will later be mapped to a modbus device register
3) Select User Parameter option from the Application dropdown
4) Add a new variable address and provide a meaningful tag name
5) Select an option that matches the modbus register type from the Data type dropdown (eg floating point for temperature reading or temperature setpoint)
6) Specify keywords, units, comments as appropriate
7) Select the Save button to add the new user parameter to the list of C-Bus Automation Controller objects

example: 
 
Add Object Dialog

example: the newly added user parameter object will appear in the objects list and its value prior to modbus mapping will be shown as the default value in this case 0.000°C

User Parameter Object

Mapping Modbus Device Registry to User Parameter
1) Select the Modbus tab from the configuration page tabs
2) From the modbus device list select the applicable modbus device's mapping icon under the mapping column
3) From the modbus device's register list select the link to object field next to the modbus register to be mapped
4) From the mapping dialog use the link to object dropdown list to link the modbus register to the corresponding user parameter
5) Specify the value delta, units, keywords and comments as applicable
6) Select Save button to link the modbus device register to the user parameter object

example: 
 
Modbus Mapping Dialog

Check User Parameter value for updates from SE8350/8650 Room Controller
1) Select the Objects tab from the configuration page tabs to display C-Bus Automation Controller objects
2) Check that the User Parameter object which was just mapped from SE8350/8650 modbus device register is updating as expected

example: we can see the Room Temp user parameter is being updated from the Room Controller One - Room Temperature modbus registry

Mapped User Parameter Object
 
 

Wiser Home Management Thermostat Documentation

Issue:
Installation and User Guides for Wiser Home Managment System Thermostats
EER56000,  EER56100,  EER58000

Product Line:
Wiser Home Management System

Environment:
Residential Single Family Home

Cause:
Solutions to many common questions can be found in the documentation.

Resolution:
User Guides and Installation Bulletins are attached.

 

What's the difference between a regular Home member, an Administrator and the Homeowner?

The Homeowner has access to all functions. Administrator has access to all functions except the ability to transfer the homeowner rights, delete the home and granting administrator rights to other members. A common member only has access to operate devices, receive notifications (alarm, moment/automation trigger, device added/removed and invite) from a home, configure device settings and schedules.

What are some ways I can save money on my home’s electricity bill?

We get asked this a lot – and rightly so. We all want to be as efficient with our energy and reduce our energy bills. Easy ways you can make immediate savings are:

  1. Installing LED lights – they use less energy, last longer and lower your environmental impact.
  2. Stop paying for standby power – even when your devices are on ‘standby mode’ they’re using power. If you’re not using them, turn them off.
  3. Check your devices’ eco settings – and turn them on! They’ll save power for you.

If you’re looking for a long-term solution, check out our Wiser Energy Management options or speak with your electrician about the best options for you. Installing Wiser Energy management solutions allows you to use the Wiser by SE app and keep track of your usage, maximise your solar, and save on bills.

You can find more tips on how you can save on your electricity bill each month here.