Clipsal Iconic Study Rocker 10 Pack

Clipsal Iconic Study Rocker, 10 Pack

Clipsal Iconic Study Rocker 10 Pack

Item Number: 40STR-VW

Retail
$33.55
RRP (Inc. GST)

Save time and energy with the convenient Clipsal Iconic Study Dolly Rocker switch that allows you to turn on and off the lights to your study or office at the flick of a switch. Easy to read pictogram allows for clear and universal identification.

Colour Vivid White (VW)
  • Vivid White 1 PCE

Product Dimensions

Width icon

Width23 mm

Height icon

Height23 mm

Depth icon

Depth9 mm

See full specifications

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range

Clipsal Iconic

Product or component type

rocker

Physical

Quantity per set

set of 10

Marking

study

Switch function

2 positions

Height

23 mm

Width

23 mm

Depth

9 mm

EU RoHS Directive

Under investigation

Environmental Disclosure

ENVPEP120506EN

Others

Unit Type of Package 1

PCE

Number of Units in Package 1

1

Package 1 Weight

14 g

Package 1 Height

9.17 mm

Package 1 width

98 mm

Package 1 Length

175 mm
Show all specifications

Frequently Asked Questions

hide show

Preventa XCS_CSA certificate of the XCSPA, XCSPL, XCSPR, XCSTA, XCSPL, XCSTR plastic safety switches

Please find attached the CSA certificate of the XCSPA, XCSPL, XCSPR, XCSTA, XCSPL, XCSTR plastic safety switches

Preventa XCS - Up-to-date CCC certificate of the XCSPA, XCSTA, XCSPL, XCSTL, XCSPR, XCSTR safety switches (origin France)

Find attached the CCC certificate of the XCSPA, XCSTA, XCSPL, XCSTL, XCSPR, XCSTR safety switches produced in France, and valid up to march 2020

XCSPL XCSTL XCSPR XCSTL safety switches - EC/EU declaration of conformity

Find attached 2016 update EC/EU declaration of conformity for our XCSPL XCSTL XCSPR XCSTR plastic safety switches. The Low Voltage and EMC directive changed.

Osisense XC_EAC certificate of the XCMD, XCK, XCS ... switches

Please find attached Russian EAC certificate of our XCMD, XCK, XCS ... switches, valid up to January 2020. It replaces the Gost certificate.

What does "CT/PT Correction Points" mean in the Instr Xformer Correction (ITC) Module on an ION meter?

In ION meters, The Instr Xformer Correction (ITC) Module is used to correct inaccuracies in the current transformers (CTs) and potential transformers (PTs). This module applies correction factors for ratio errors and phase angle errors to instrument transformers, hence, reducing or eliminating the need to replace transformers in installations where high-accuracy is required.
The module in summary requires to enter a set of example data, then applies interpolation based on the data set given to the correct inaccurate Voltage-Current values. In the module, the Phase Correction Data setup register is used to enter a string of delimited pairs of the test points and associated error for the phase angle of the CT or PT. The test point is expressed as a percentage of the rated secondary nominal rating. The phase angle error is expressed as a real value in minutes.

The Test Point mentioned above is also known as CT/PT Correction Points in industry.


Date Created: June 4, 2009
Last Revised: July 16, 2009
Public
Original Author: KG
All content © 1992-2009 Schneider Electric


Legacy KB System (APS) Data: RESL199373 V1.0, Originally authored by MiNe on 07/17/2009, Last Edited by MiNe on 07/17/2009
Related ranges: ION8600, ION7550/ION7650

What does Neg stand for under logic inputs in SFT2841?

Product Line  
SEPAM 20
SEPAM 40
SEPAM 50
SEPAM 80

Resolution   
There is a Neg box for the logic inputs in SFT2841. This option, if checked, allows one to wire the input as a negative input. For instance, 1 is normally considered to be high, if you checked Neg, you would effectively be telling the relay that 0 is high.

 

SEPAM Series 40 and 50 Wiring Diagram

Issue  
Need the wiring diagram for the SEPAM 40 and 50.

Product Line   
SEPAM Series 40
SEPAM Series 50


Resolution   
Attached is the wiring diagram for the all SEPAM Series 40 and 50.

Cutout diagram for the SEPAM 40 and 50.

Issue  
Need the cutout diagram for the SEPAM 40 and 50.

Product Line   
SEPAM Series 40
SEPAM Series 50


Resolution   
Attached is the cutout diagram for the all SEPAM Series 40 and 50.
 

How long does it take the digital input for logic discrimination (ZSI) to be recognized by the Sepam relay?

Issue
User wishes to know how long it takes the digital input for ZSI to be recognized by Sepam relay

Product Line
Sepam series 20
Sepam series 40
Sepam series 80

Environment
Performance

Resolution
It takes approximately 13 ms (one cycle time of the control reading) operating time for the relay to recognize and react to an input change.

Note: For a Sepam series 20, only input I13 can be used to receive a blocking reception.

Unable to access PowerChute Business Edition or PowerChute Network Shutdown web interface with default browser using localhost as the IP address

Issue:
Unable to access PowerChute Business Edition or PowerChute Network Shutdown web interface with default browser using localhost as the IP address
Example: https://localhost:6547

Products:
PowerChute Business Edition web Agent all version
PowerChute Network Shutdown web client all version

Environment:
Linux OS running Mozilla Firefox versions 37, 38, 39, 40

Cause:
https://bugzilla.mozilla.org/show_bug.cgi?id=1148766

Solution:
Upgrade Mozzilla Firefox to version 51.or access the web interface using https://<system IP>:6547 
Examples: https://192.168.1.10:6547



 

SFT2841 Setting and Operation Software Overview

Issue  
Need an overview of the SFT2841 software for the SEPAM relay.

Product Line   
SFT2841
SEPAM 20
SEPAM 40
SEPAM 80


Resolution   
The SFT2841 software is the setting and operating tool for SEPAM series 20, SEPAM series 40 et SEPAM series 80. It may be used in 2 operating modes:
  •  unconnected to SEPAM, to prepare parameter and protection settings
  •  connected to SEPAM, to download and upload SEPAM parameter and protection settings and have access to all operating functions.
Please see attachment for more information.

Input Circuit Breaker Requirements for Symmetra PX 20/40/80 kw


Issue:
This document describes the required input over current protection (circuit breaker) required when installing a Symmetra PX

 
Product line:
Symmetra PX1 Products


Environment:

All models/ all serial numbers

Cause:
Input Circuit Breaker Requirements for Symmetra PX 20/40/80 kw

Resolution:
ISX 20K (All-in-One)
90A 208vac

Symmetra PX 40
175A 208vac
80A 480vac (PDU w/ Step Down Transformer required)
60A 600vac (PDU w/ Step Down Transformer required)

Symmetra PX 80
350A 208vac
150A 480vac (PDU w/ Step Down Transformer required)
125A 600vac (PDU w/ Step Down Transformer required)


For more information about this subject please refer to Application Notes 148, 149, and  150. (APC Symmetra PX Frame Installation Deviation and Selection of Input Circuit Breaker Ratings)

App note 150
https://www.apc.com/salestools/AWAR-7KEP2T/AWAR-7KEP2T_R0_EN.pdf
 
App note 149
https://www.apc.com/salestools/AWAR-7KEPUW/AWAR-7KEPUW_R0_EN.pdf
 
App note 148
https://www.apc.com/salestools/AWAR-7KEQPR/AWAR-7KEQPR_R0_EN.pdf