Clipsal Iconic Gridplate and Mechanism 2 Gang, 250V, 10AX

Clipsal Iconic Gridplate and Mechanism 2 Gang, 250V, 10AX

Clipsal Iconic Gridplate and Mechanism 2 Gang, 250V, 10AX

Item Number: 3042VAG

Retail
$23.05
RRP (Inc. GST)

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-
Clipsal Iconic 3025 exploded view
3043G Rear Perspective

Specifications

Frequently Asked Questions

hide show

Does part number 3044V44 available in Cool Grey?

Part number comes standard as Vivid White, will need Cool Grey cover to suit.
 

What is the part number for a 2 gang Iconic switch plate and switch mech and dimmer?

The part number for a 2 gang Iconic switch plate and switch mech and dimmer is - 3042HA , 40M & 41E300PBUD2SM

For further information , visit link below:-
https://www.clipsal.com/Trade/search-results?q=3042HA
https://www.clipsal.com/Trade/search-results?q=40M
https://www.clipsal.com/Trade/search-results?q=41E300PBUD2SM
User-added image

What is the part number for the 1 gang Iconic switch , and can the mech be rotated for horizontal or vertical switch plates?

The part number for the 1 gang Iconic switch , and can the mech be rotated for horizontal or vertical switch plates - 3041VA and yes can be mounted Vertical or Horizontal..
For further information , visit link below:-
https://www.clipsal.com/Trade/search-results?q=3041VA
User-added image

What metal wall box suits the 39/2VA?

The wall box that suits the 39/2VA is 157/2.

Some of the key features are:
  • Sliding nut
  • 84 x 46 mm mounting centre
  • Suits universal wall construction
  • Horizontal and vertical mounting
For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=157/2



 

What can cause an USF (undervoltage fault) on an ATV12 drive?

Issue: 
USF (undervoltage fault) on an ATV12 drive.

Product Line:
Altivar 12

Environment:
All

Cause:
Fault condition

Resolution:
For N4, 480V drives at factory setting of 480VAC, the threshold is 430VDC on the DC bus or 304VAC on the line terminals. 
For M3, 240V drives at factory setting of 260VAC, the threshold is 230VDC on the DC bus or 163VAC on the line terminals.

Recommendations:
- Measure the the incoming line to line voltages
- Compare the line voltage to the Mains Voltage as shown under monitoring MON.
- If the standard line voltage is low, you can adjust the Mains voltage setting
- Adjust the Undervoltage time out to compensate for line contactors, or add time delay before a fault would occur. 
- Check to issues where line potential is dropping due to supply issues that may be caused by load pulling too much current.

Do you do a ICONIC switch 5 gang with LED's?

The ICONIC switch 5 gang is not available with LED's however can be purchased then LED's can be added so a 3045-VA and a 40MLEDW
Show More
Exploded view of the Clipsal Iconic skins range; Styl, essence and Standard.

Range

Customisable and future-ready

Iconic is based around a unique, electrically safe grid plate, with a choice of three different skin designs that simply clip on top.

Once the grids have been installed by an electrician, it’s safe for anyone to change the skins at any time. Simply clip off the standard skins and clip on the new design.

Interchangeable standard, Styl and Essence skins provide great options to customise to suit specific decor and lifestyle.