Compact Interpact Switch Disconnector INS125, 3 Poles, 125A

Compact Interpact Switch Disconnector INS125, 3 Poles, 125A

Compact Interpact Switch Disconnector INS125, 3 Poles, 125A

Item Number: 28910

Retail
$596.12
RRP (Inc. GST)

Product Dimensions

Width icon

Width135 mm

Height icon

Height100 mm

Depth icon

Depth62.5 mm

See full specifications

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range

Compact

Range of product

INS40...160

Product or component type

switch disconnector

Sustainable offer status

Green Premium product

Warranty

18 months

Physical

[Ie] rated operational current

  • AC-22A: 125 A AC 50/60 Hz 220/240 V
  • AC-23A: 80 A AC 50/60 Hz 660/690 V
  • DC-22A: 125 A DC 125 V 2 poles in series
  • DC-23A: 125 A DC 125 V 2 poles in series
  • AC-22A: 125 A AC 50/60 Hz 380/415 V
  • AC-22A: 125 A AC 50/60 Hz 440/480 V
  • AC-22A: 125 A AC 50/60 Hz 500 V
  • AC-22A: 125 A AC 50/60 Hz 660/690 V
  • AC-23A: 125 A AC 50/60 Hz 220/240 V
  • AC-23A: 125 A AC 50/60 Hz 380/415 V
  • AC-23A: 125 A AC 50/60 Hz 440/480 V
  • AC-23A: 125 A AC 50/60 Hz 500 V
    • [Ue] rated operational voltage

    • 125 V DC
    • 690 V AC 50/60 Hz
      • Control type

        rotary handle

        Mounting mode

        fixed

        Mounting support

      • DIN rail
      • plate
        • Mechanical durability

          15000 cycles

          Electrical durability

        • AC-22A: 1500 cycles 220/240 V AC 50/60 Hz
        • DC-23A: 1500 cycles 250 V DC 2 poles in series
        • AC-22A: 1500 cycles 690 V AC 50/60 Hz
        • AC-23A: 1500 cycles 690 V AC 50/60 Hz
        • AC-22A: 1500 cycles 380/415 V AC 50/60 Hz
        • AC-22A: 1500 cycles 440 V AC 50/60 Hz
        • AC-22A: 1500 cycles 500 V AC 50/60 Hz
        • AC-23A: 1500 cycles 220/240 V AC 50/60 Hz
        • AC-23A: 1500 cycles 380/415 V AC 50/60 Hz
        • AC-23A: 1500 cycles 440 V AC 50/60 Hz
        • AC-23A: 1500 cycles 500 V AC 50/60 Hz
        • DC-22A: 1500 cycles 250 V DC 2 poles in series
          • Height

            100 mm

            Width

            135 mm

            Depth

            62.5 mm

            Net weight

            0.8 kg

            Standards

          • IEC 60947-1
          • IEC 60947-3
            • Product certifications

            • CCC
            • KEMA-KEUR
              • IP degree of protection

                IP40 conforming to IEC 60529

                IK degree of protection

                IK07 conforming to EN 50102

                Ambient air temperature for operation

                -25-70 °C

                Ambient air temperature for storage

                -50-85 °C

                REACh free of SVHC

                Yes

                EU RoHS Directive

                Compliant

                Toxic heavy metal free

                Yes

                Mercury free

                Yes

                RoHS exemption information

                Yes

                China RoHS Regulation

                X

                Environmental Disclosure

                ENVPEP1304024

                California proposition 65

                WARNING: This product can expose you to chemicals including: DINP and DIDP which is known to the State of California to cause Carcinogen and Reproductive harm. For more information go to www.p65warnings.ca.gov

                Others

                Product name

                Compact INS

                Device short name

                Compact INS125

                Switch-disconnector name

                Compact INS125

                Poles description

                3P

                Network type

              • AC
              • DC
                • Network frequency

                  50/60 Hz

                  [Ui] rated insulation voltage

                  750 V AC 50/60 Hz

                  [Uimp] rated impulse withstand voltage

                  8 kV

                  [Ith] conventional free air thermal current

                  125 A at 60 °C

                  [Icm] rated short-circuit making capacity

                • 154 kA with upstream protection circuit breaker 690 V AC at 50/60 Hz
                • 20 kA switch-disconnector alone 690 V AC at 50/60 Hz
                  • Suitability for isolation

                    yes

                    Contact position indicator

                    yes

                    Visible break

                    no

                    Pollution degree

                    3

                    Handle colour

                    black

                    Upside connection

                    front

                    Downside connection

                    front

                    Maximum power

                  • AC-23: 55 kW at 440 V AC 50/60 Hz
                  • AC-23: 37 kW at 220/240 V AC 50/60 Hz
                  • AC-23: 55 kW at 380/415 V AC 50/60 Hz
                  • AC-23: 75 kW at 500/525 V AC 50/60 Hz
                  • AC-23: 75 kW at 660/690 V AC 50/60 Hz
                    • Rated duty

                      uninterrupted

                      Intermittent duty class

                      class 120 - 60 %

                      Enclosure dimensions for Ithe

                      260 mm x 160 mm x 55 mm

                      [Icw] rated short-time withstand current

                    • 0.01 kA during 30 s conforming to IEC 60947-3
                    • 1.23 kA during 20 s conforming to IEC 60947-3
                    • 3.175 kA during 3 s conforming to IEC 60947-3
                    • 5.5 kA during 1 s conforming to IEC 60947-3
                      • Connection pitch

                        30 mm

                        Compatibility code

                        INS125

                        Unit Type of Package 1

                        PCE

                        Number of Units in Package 1

                        1

                        Package 1 Weight

                        1.026 kg

                        Package 1 Height

                        11.4 cm

                        Package 1 width

                        13.4 cm

                        Package 1 Length

                        15.8 cm

                        WEEE

                        The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
                        Show all specifications

                        Documents & downloads

                        hide show

                        Frequently Asked Questions

                        hide show

                        Extended front rotary handle for the 28910 INS 125A Load Break Switch ?

                        Code = LV428941

                        What is the part code for IN160T options

                        The part code is a 28912

                        What is the part code for a din rail mounted isolator, 3P 150A

                         You can use a 28912

                        Is there a front mounted extended handle to fit the 28912?

                        Yes it is the 28941.

                        What is the replacement for a 5 Series Load Breaker 5LBC4125CD?

                        The replacement for 5 Series load breaker 5LBC4125CD is a schnieder 31335.

                        For further information please visit the link below.

                        https://www.schneider-electric.com.au/5ser31335

                        https://www.elteh.eu/wp-content/uploads/schneider/H619250_web.jpg

                        What is the Form Y234?

                        Issue:
                        8910 form Y234

                        Product Line:
                        Class 8910, 8911 8965 Definite Purpose Contactors

                        Environment:
                        Types DP, DPA, DPS, DPR

                        Resolution:
                        The Form Y234 is a factory modification to mount the nameplate upside down for 8910, 8911 & 8965 DP, DPA, DPR & DPS only.
                        This form is no longer available.  Complete a TAG request with the factory to ask for this modification.
                        Show More