Quantcast

Conduit Clip, PVC, 20mm

Black | Conduit Clip, PVC, 20mm

Conduit Clip, PVC, 20mm

Item Number: 280HF20-BK

Retail
$22.50
RRP (Inc. GST)
Colour Black (BK)
  • Black 1 PCE

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Product brand

Clipsal

Range of product

Series 280

Physical

Environmental characteristic

  • halogen free
  • fire resistance
    • REACh free of SVHC

      Yes

      EU RoHS Directive

      Pro-active compliance (Product out of EU RoHS legal scope)

      Toxic heavy metal free

      Yes

      Mercury free

      Yes

      RoHS exemption information

      Yes

      China RoHS Regulation

       Pro-active China RoHS declaration (out of China RoHS legal scope)

      Material

      Material

      PVC (polyvinyl chloride)

      Others

      Diameter

      20 mm

      Sheath material

      plastic

      Unit Type of Package 1

      PCE

      Number of Units in Package 1

      1

      Package 1 Weight

      4 g

      Package 1 Height

      12 mm

      Package 1 width

      28 mm

      Package 1 Length

      29 mm
      Show all specifications

      Frequently Asked Questions

      hide show

      Are the Clipsal Conduit Clips available in Electric Orange?

      No, they are only available in grey.

      This applies to the 280/16 (16mm), 280/20 (20mm), 280/25 (25mm), 280/32 (32mm), 280/40 (40mm) and 280/50 (50mm).

      What is the part number for an inspection elbow to suit 9020HF20-BK?

      The part number for an inspection elbow to suit the 9020HF20-BK is 244HF20-BK.
       

      What is the part number for inspection tee to suit 9020HF20-BK?

      246HF20-BK is the part number for inspection tee to suit 9020HF20-BK.

      Where can people purchase Stab-Lok breakers?

      Issue:
      Are Federal Pioneer / Federal Pacific Stab-Lok breakers available? 

      Product Line:
      Moulded Case Breakers

      Environment:
      Stab-Lok

      Cause:
      FP Product Availability

      Resolution:
      Contact American Circuit Breaker Corporation (ACB) at 704-463-7361 as they are the exclusive distributor of the Stab-Lok breaker.

      Who provides support for Class 9045 Type BG Magnetic Unloader products?

      Issue:
      Replacement for a defective magnetic unloader

      Product Line:
      Pressure, Float and Limit switches

      Environment:
      Pressure Switches

      Cause:
      Support for obsolete pressure switch  

      Resolution:
      The 9045 BG Magnetic unloaders were electrically activated relief valves used to relieve head pressure on compressors. These devices have been obsolete for several years with no replacement. Users should contact the compressor OEM for suggested replacement.

      How do I hardwire 10kva and 20kva transformers in a 208/120 or 240/120 environment

      Issue:
      Implementing a hardwire stepdown transformer in a 208v or 240v environment


      Product Line:

      Smart-UPS / Symmetra

      Environment:

      APTF10KT01, APTF10KW01, and APTF20KW01, All Serial Numbers

      Cause:

      Unbalanced UPS outputs require a stepdown transformer to power 120v loads


      Resolution:

      This document refers to installing  the APTF10KT01, APTF10KW01, and APTF20KW01 transformers in a North American 120/240 or 120/208 environment. For installations in other regions please consult the users manual.

      The wiring block outputs are as follows:


      For domestic use, make sure that the Terminal Block Jumper is installed between the Ground Terminal and Terminal 8 on the output wiring block, as illustrated on page 8 of the user manual. Please also make sure that the input voltage switch is in the correct position.

      The step-down transformer provides 240/120 output as 2 120v hots, a neutral, and a ground. It provides 208v output as a 120v hot, an 88v hot, and a ground. The 120v hot (terminal  7) and the 88v hot (terminal 9) are 180 degrees out of phase. You will measure 208v from terminals 7 to 9. The step-down transformer is not able to provide 2 120v hots that are 120 degrees out of phase as you would see with utility power.



       Note: If your installation requires both 208v and 120v output power you will need 2 separate subpanels: a 240v/120v panel and a dedicated 208v subpanel.