sock swt sing rem 2xe/sw sh

Single Switched Socket With Two Removable Extra Switches Shutter

Catalogue Number: 2015XXS
sock swt sing rem 2xe/sw sh
Colour: White Electric
Colour: Per UOM Std.
  • White Electric 1 PCE
Added to cart

Specifications

hide show
Product brand
Clipsal
Range of product
Series 2000
Control type
ON/OFF button
Number of gangs
1 gang
Pin number
3
Number of power socket outlets
1
Actuator
  • rocker
  • switch
    • Mounting position
      horizontal
      Fixing mode
      by screws
      Local signalling
      without light indicator
      Material
      plastic
      Surface finish
      glossy
      [Ue] rated operational voltage
      250 V AC
      [In] rated current
      10 A
      Depth
      12 mm
      Length
      120 mm
      Width
      76 mm
      Fixing center
      84 mm
      Standards
    • AS/NZS 3100
    • AS/NZS 3112
    • AS/NZS 3133:approval number S/1
      • Sustainable offer status
        Green Premium product
        REACh Regulation
        Free of Substances of Very High Concern above the threshold
        REACh free of SVHC
        Yes
        EU RoHS Directive
        Compliant
        Toxic heavy metal free
        Yes
        Mercury free
        Yes
        RoHS exemption information
        Yes
        China RoHS Regulation
         Pro-active China RoHS declaration (out of China RoHS legal scope)
        Environmental Disclosure
        ENVPEP111024EN
        Circularity Profile
        ENVEOLI110713EN

        Frequently Asked Questions

        hide show

        What is the PDL version of the 2015XX?

        The PDL version of the 2015XX is a PDL694XXWH.

         

        Can part number 2015X accommodate TV mech?

        A TV mech CAN NOT be put into 2015X. Must have at least 150mm of separation.
         

        Is there a C2015s with built in surge filter?

        No, we dont sell one complete, you would have to get a C2015XS take out the extra switch and put in a 30SFM.

        Is mech removable in part number 2015X?

        Yes, the mech in part number 2015X is removable.

        For more information on this part please refer to https://www.clipsal.com/Trade/Products/ProductDetail?catno=2015X


        User-added image

        Is there a C2015XX cover in brushed aluminium?

        Yes, the part number for the cover in brushed aluminium is C2015XXC-BA

        Some of the features of the C2015XX are:
        • 2 Removable extra switch
        • Terminals suits 4 x 2.5 sq mm cables
        • 250V rated
        • 10A rated
        • C2000 Series
        For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=C2015XX 

        Are the extra switches in the C2015XX removeable?

        Yes, the extra switches in the C2015XX are removable.

        Some of the key features are:
        • 2 Removable extra switch
        • Terminals suits 4 x 2.5 sq mm cables

        For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=C2015XX
         

         

        What is the part number for a double GPO with Shutters and an ID window?

        The part number for a double GPO with Shutters and an ID window is - 2025XAS & 30PID

        For further information , visit links below:-
        https://www.clipsal.com/Trade/search-results?q=2025XAS
        https://www.clipsal.com/Trade/search-results?q=30PID
        User-added image
        User-added image

        Will 30USBCM fit on a C2000, Classic series plate?

        30USBCM will fit on C2015X / C2015XX / C2025X* / Up to 3-gang Classic series switch plates.
        For further information on 30USBCM, please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=30USBCM
         

        What is the part number for a Classic single GPO with 2 USB outlets in Black?

        The part number for a Classic single GPO with 2 USB outlets in Black is - C2015XX   + 30USBCM   +   USCBC-CAPS-BK

        For further information , visit link below:-
        https://www.clipsal.com/Trade/search-results?q=C2015XX
        User-added image

        Can the SC2015XX take a USB mech?

        Yes the SC2015XX will take a USB mechanism.

        Does the 2025VXA have shutters on the outlets?

        Yes, the 2025VXA does come with shutters.

        What colours does the 2025VXA come in?

        2025VXA White is the only commercilaized colour in NZ.
         
        2025VXA-WE

        Customer asked if the manual transfer switches are available with an interlocked receptacle option?

        No


        CTA-ID : 2015863

        Is there a double pole 15A outlet?

        Yes, the part number is a 2015D15

        What is part no for 15amp vertical single GPO

        PART NO 2015V15

        What is the part code for a saturn single horizontal socket in Horizon Silver

        The part number is 4015-HS

        In the 600 Series, is the 691/15 available in RED

        Not available, but Clipsal 2015/15 is available in red but it's horizontal.

        Is there a 2000 series plate 2025 with an ID window like the 2025XUA with a 30PID?

        The part name is 2025XAPID-WE

        Can I fit a USBC into a P2015X?

        Yes, you can put a USBC into a P2015X by using a P30Z as long as the extra switch is removable.

        Is there a 2000 Series plate 2025 with an ID window like the 2025XUA assembled with a 30PID?

        The part number for a 2000 Series powerpoint with an ID window like the 2025XUA assembled with a 30PID is 2025XAPID.
        Some of the key features are:
        • 30 PID
        • Removable extra switch
        • 10A
        • 250V
        For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=2025XAPID


         

        What is the part number for a cover for a latest vertical GPO with extra switch , C2015X?

        The part number for a cover for a latest vertical GPO with extra switch , C2015X is - C2015VXC2.

        For further information , visit link below:-
        https://www.clipsal.com/Trade/search-results?q=C2015VXC2

        What is the part number of a replacement button cap for an XB4BA21?

        Issue:
        What is the part number of a replacement button cap for an  XB4BA21?

        Product Line:
        Harmony Pushbuttons

        Environment:
        All Products

        Cause:
        Product selection

        Resolution:
        Use a ZBA2 black cap or otherwise the black cap from a universal ZBA9 kit


        CTA-ID : 2015097

        What is the part number for a diode for a CA3KN relay?

        Issue:
        What is  the part number for a diode for a CA3KN relay?

        Product Line:
        Tesys Relays

        Environment:
        All Products

        Cause:
        Product selection

        Resolution:
        LA4KC1B or LA4KC1E is the diode and zener diode for the CA3KN relay.


        CTA-ID : 2015604

        What is the part code for a very old PDL Shaver Socket Conversion Plate

        The conversion plate is no longer available but you can use the below part numbers for the Clipsal version
        2000/3-WE + 2015-WE + 2727-WE + 2031RC30-WE

        What is the code for the cover plate to suit the C2025XAS Double power outlet 250V 10A with shutters and extra switch?

        C2025XC - available in White (WE), Brushed Aluminium (BA), Chrome (CH) and Gold (GD).

        Are there double GPO's that are individually wired on each side?

        Yes, there are a few GPO's that are individually wired, they are C2016/2, 16/2MF, 2015/2V and 15/2V. In a weather proof option we have the WSC227/1/2

        What is the part number for a powerpoint with double USB charger in black?

        This will require a 2015XX-BK + 30USBCM-WE X2 + USBC-CAPS-BK

        What is part number for cover to suit C2015X?

        The part number is a - C2015XC.

        For more information on this part please refer https://www.clipsal.com/Trade/Products/ProductDetail?catno=C2015XC


        User-added image

        Can a factory-installed provision for a keylock be ordered with an NW breaker?

        Issue:
        Factory installation of key interlock provisions on NW Masterpact circuit breakers.

        Product Line:
        Circuit Breakers

        Environment:
        Products sold and used in the United States

        Cause:
        Factory installed key interlock on NW Masterpact circuit breakers

        Resolution:
        It is possible to order "provision-only" for an NW breaker key interlock. The provision is also available as a field-installable kit. See pricing guide for catalog numbers.

        CTA-ID : 2015133

        Why is the drive not responding to the 4-20mA feedback signal when the Pump Switching Card is installed?

        Most common issue is Parameter o19 must be set to the maximum pressure of the sensor in Bars.  Parameter o20 is set to the PI setpoint in Bars.

        To get the pressure in Bars, divide the pressure in PSI by 14.504.


        CTA-ID : 2015151

        What is the difference between the XACA201 and XACA205 pendant stations?

        Issue:
        What is the difference between the XACA201 and XACA205 pendant stations?

        Product Line:
        Pendant Stations

        Environment:
        All products

        Resolution:
        XACA201 has 1-NO contact on each button. The XACA205 has 1-NO on one button and 1-NC contact on the other button.

        Is the CA2KN22G7 DIN rail mountable?

        Issue:
        Is the CA2KN22G7 DIN rail mountable?
        Product Line:
        Industrial Relays
        Environment:
        Tesys K IEC Style Relays
        Cause:
        Determine how to mount for application.                             
        Resolution:                                                                 
        Yes. They are made to mount on 35mm DIN3 type mounting rail.
         

        Are parts still available for the obsolete CME product line?

        Issue:
        Old Product Design metering

        Product Line:
        Commercial Metering Equipement (CME)

        Ennvironment:
        Repair parts

        Cause:
        Maintenance

        Resolution:
        All CME parts are obsolete and no longer available. 


         

        What is the ampere rating for dc voltages for the 9001KA contact blocks?

        Issue:
        DC ampere rating for 9001KA contact blocks

        Product Line:
        Harmony Push Buttons

        Environment:
        Harmony 30mm

        Cause:
        Product Features

        Resolution:
        2.5A continuous up to moved. (NEMA Q600)

        What is the part no for a double powerpoint with a larger space in between to use with power packs?

        The part no is 2015H2. It is 2 x single horizontal switched sockets side by side with a single frame.

         

        Is a double power point with neon & USB available in Red ?

        Part no 2025XAN can be used the USB has to mount vertically to enable it to fit

        Red is not a standard colour for this part but it can be made as a special

        How to recover my password for M221 SoMachine Basic project file?

        It is possible to encrypt and password-protect a project file. 
        For security policy reasons, in the design of the software there is no built-in way to bypass that project protection password.



        Project Password Setup

        Verifies against SoMachine Basic v1.6
         

        What is the replacement part codes for RUMC2AB2 & RUM3CAB2?

        References changed in 2015
        RUMC2AB2•• becomes RUMC22••
        RUM3CAB2•• becomes RUMC32••

        the above codes use the same bases:
        RUMC22••/ RUMC2AB2•• = RUZC2M
        RUMC32••/ RUMC3AB2•• = RUZC3M

        What are the part number for a 15 amp outlet with RCD protection?

        Not available as 1 unit. Would have to use 2015/15 with 2031VRCD30
        For further information , visit links below:-
        https://www.clipsal.com/Trade/search-results?q=2015/15
        https://www.clipsal.com/Trade/search-results?q=2031VRCD30
        User-added image
        User-added image

        What are the dimensions for 8639 LPA4NA & LNA4NA?

        Issue: What are the dimensions for 8639 LPA4NA & LNA4NA?
         
        Product Line: 8639 ATS46
         
        Environment: 8639 LPA4NA & LNA4NA
         
        Cause: N/A
         
        Resolution: Theses are Floor mount unit at 34.21 inches wide, 92.68 inches tall, 26.00 inches deep with disconnect handle extended.

        The wieght is 850 lbs

        This is the same for class 8638 & 8639 Type NI - NQ standard duty and LM - LP heavy duty.


         

        What is the ATS48 line voltage operating range?

        Issue:
        What is the ATS48 line voltage operating range?

        Product line:
        Altistart 48, ATS48

        Environment:
        all

        Cause:
        n/a

        Resolution:
        The Altistart 48 is suitable for three phase supply voltages that range from 208VAC to 690VAC , 50/60Hz.  The tolerance of the voltage supply is -15% to +10%. 

         

        Are replacement contacts available for a CAD32 relay?

        Issue:
        Contacts need to be replaced in a CAD32** relay.

        Product Line:
        TeSys D IEC style relays

        Environment:
        CAD relays

        Resolution:
        The TeSys D IEC style relays do not offer replacement parts.  Replace entire device.

        Will the accessories used for the GV3ME06 through GV3ME63 work with the GV3ME80?

        Product Line:
        GV3 manual motor starters, IEC

        Resolution:
        The standard GV3 accessories will work on this device.

        What is the difference between 9001SKYP4 and SKYP40?

        Issue:
        What is the difference between 9001SKYP4 and SKYP40?

        Product Line:
        Harmony Control Stations

        Environment:
        All Products

        Cause:
        Product Features

        Resolution:
        9001SKYP4 is the enclosure only if customer wishes to order pendant station in components.
        9001SKYP40 is the enclosure catalog if customer wishes to order pendant station as completely assembled with operators, contact blocks and legend plates and requires key sheet.


         

        What is the lock out device for a 9001BW241?

        Issue:
        Is the lock out device on 9001BW241 sold separately?

        Product Line:
        Pushbuttons and Operator Interface

        Environment:
        9001B Standard Duty Control Stations

        Cause:
        Product Selection

        Resolution:
        The lock out is not offered as a separate item. Replace the cover with 9001BWD220 tha has a lockout factory installed on it.

        What is the difference between ZB2BZ101 and ZB2BE101?

        Issue:
        What is the difference between ZB2BZ101 and ZB2BE101?

        Product Line:
        Push Buttons

        Environment:
        22mm Push Buttons

        Cause:
        Product Features

        Resolution:
        ZB2BZ101 is a ZB2BE101 (normally open contact block) + ZB2BZ009 mounting collar




         

        Is there a padlock device for the 9001KR9R?

        Issue:
        What Padlock Device can be used on the 9001KR9R E-stop Pushbutton?

        Product Line:
        Harmony Pushbuttons

        Environment:
        All Products

        Resolution:
        9001K62, 9001K162
        NOTE: These attachments will not work when the operator is supplied with a 2 1/4 inch diameter mushroom.

        Important security notification: M340, Quantum, Premium and STB Ethernet communication modules (ICS-ALERT-11-346-01)

        Goals and Symptoms

        Notification and recommendations concerning security as found in ICS-ALERT-11-346-01
        Updated Aug. 20, 2015
        This is an update to previous Resolution RES206895.

        Causes and Fixes

        See Attached document

        Attachments

        What is the part number for a replacement for 15/15/EL30?

        There is no direct replacement for this unit. Customer would be able to use 3 items to make this up - 2015/15 , 2031RC30 & 2000H2

        For further information , visit links below:-
        https://www.clipsal.com/Trade/search-results?q=2015/15
        https://www.clipsal.com/Trade/search-results?q=2031RC30
        https://www.clipsal.com/Trade/search-results?q=2000H2
        User-added image

        User-added image
        User-added image

        How can the ATV28 unit be run at a set speed without a speed signal input?

        Issue:   How can the ATV28 unit be run at a set speed without a speed signal input?
         
        Product Line:   ATV28
         
        Environment:  All
         
        Cause:   N/A
         
        Resolution:   
        If a forward or reverse run signal is given to the drive using the logic inputs and no speed signal is present, the drive will run at the LSP (low speed) setting. The factory default low speed setting is 0 Hz. This setting can be changed while the drive is running.


         
        Show More