Single Switch Socket Outlet, 250V, 10A, Removable Extra Switch, Safety Shutter

White Electric | Single Switch Socket Outlet, 250V, 10A, Removable Extra Switch, Safety Shutter

Single Switch Socket Outlet, 250V, 10A, Removable Extra Switch, Safety Shutter

Item Number: 15XS-WE

Retail
$121.92
RRP (Inc. GST)

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Sustainable offer status

Green Premium product

Product brand

Clipsal

Range of product

Standard Series

Surface finish

glossy

Physical

Environmental Disclosure

ENVPEP120506EN

Mercury free

Yes

REACh Regulation

Free of Substances of Very High Concern above the threshold

China RoHS Regulation

Product out of China RoHS scope. Substance declaration for your information

EU RoHS Directive

Compliant

RoHS exemption information

Yes

Control type

ON/OFF button

Number of gangs

1 gang

Pin number

3

Number of power socket outlets

1

Actuator

  • rocker
  • switch
    • Mounting position

      horizontal

      Fixing mode

      by screws

      Local signalling

      without light indicator

      [Ue] rated operational voltage

      250 V AC

      [In] rated current

      10 A

      Depth

      14 mm

      Length

      115 mm

      Width

      73 mm

      Fixing center

      84 mm

      Standards

    • AS/NZS 3100
    • AS/NZS 3112
    • AS/NZS 3133
    • AS/NZS 3000:approval number S/1
      • Material

        Material

        PC (polycarbonate)

        Others

        Number of Units in Package 1

        1

        Number of Units in Package 2

        5

        Number of Units in Package 3

        50

        Package 1 Height

        14 mm

        Package 1 Length

        115 mm

        Package 1 Weight

        0.036 kg

        Package 1 width

        73 mm

        Package 2 Height

        117 mm

        Package 2 Length

        138 mm

        Package 2 Weight

        5 kg

        Package 2 width

        102 mm

        Package 3 Height

        157 mm

        Package 3 Length

        445 mm

        Package 3 Weight

        50 kg

        Package 3 width

        305 mm

        Unit Type of Package 1

        PCE

        Unit Type of Package 2

        BB1

        Unit Type of Package 3

        CAR
        Show all specifications

        Documents & downloads

        hide show
        Filter items
        • All

        • Product Brochures

        • Technical Data Catalogues

        • Specifications

        Frequently Asked Questions

        hide show

        Is the extra switch in the 15X removable?

        Yes, the extra switch in the 15X is removable. Any 230v rated 30 series mec will fit in it's place.

         

        Do you have a 15S in biege?

        No, the 15S only comes in White Electric and Red.

        Some of the key features are:
        • 1 pole
        • Standard size
        • Safety shutter
        For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=15Shttps://www.clipsal.com/Trade/Products/ProductDetail?catno=15S

        What is the maximum DC voltage per pole for TeSys D range contactors.

        The maximum DC voltage for TeSys D range contactor is 75 Volt per pole. This voltage is applicable for the specification of L/R <= 15ms in DC applications.

        How does the Test Button on the RH99 work?

        When the test push button is activated the switch SW1 is moved on Test position. The measurement of the network is temporarily stopped during 15ms and a sinusoidal signal of 500Hz to simulate a trip is sent to create a current of 100µA inside the resistor R. The signal seen by the toroid sensor is really negligible about the test signal injection.
        During the test signal injection the settings are: Idn = 30mA and tfault = 0.
        At the end of the 15ms delay
        -> if the product trips (TEST OK) the fault LED and the Fault order relay are activated (in case of no trip test only the fault LED is activated). We have to push on the push button Reset to remove the failure create by the test (in case of automatic reset product no action need to remove the failure).
        -> if the product doesn’t trip, no LED, no relay order the TEST is NOK and it means the product doesn’t work.
        After the 15ms of test signal injection the switch SW1 comes back to the measure position and re-starts the monitor of the network with the customer settings (in the front face).
        So if a trip occurs during the test, it will be see directly after the 15ms of test signal injection and it will be impossible to remove the failure state by a push on Reset push button.
         
        The toroids used on the Vigirex range have only one winding inside.   
         
        There is no Calibration procedure for this product. The product is designed to provide the accuracy specified on the catalogue for the product life time.


         

        What is the minimum pulse width or duration required on a IOX or IOC module to register an input status change on the CM4000 series meter?

        Issue
        Minimum pulse or duration required on a IOX or IOC module on a CM4000 series meter

        Product Line
        CM4000 series meter

        Environment
        Hardware Specifications

        Resolution
        The minimal pulse duration per input on the CM4000 IOX or IOC is 15ms when the control power to the meter is DC voltage. For AC voltage to the control power the minimal input pulse duration is 23ms.

        How to configure ATS22 to test an unloaded motor?

        Issue:
        Can an unloaded motor be tested with an ATS22 Softstarter?

        Product Line:
        Altistart 22

        Environment:
        Shop tests, unloaded motor

        Cause:
        Testing the ATS with an unloaded motor, usually trips the ATS22 with SSCr.

        Resolution:
        Yes.
        After entering the correct motor data, set the following parameters:

        - LAC = ON
         - t90 =  Factory 30 change to 10. ( Due to No Load connected and monitor ramp acceleration. This value to be changed back or increased when in the field under actual start-up )
        - ILt =    Factor 350 change to 200% for Shop Testing. ( Value to be changed in the field if Current Limit trips out )
        - tLS =   Factory 15s change to 60s for Shop Testing. ( Changed back to 15s after completion of testing )
        - ACC = Factory 10s change to 60s for Shop Testing. ( Changed back to 10s after completion of testing )
        - SSC = Factory On, changed to oFF. ( Using Voltage control vs. Torque )
        - ItH =   On. ( Factory is On)

        Show More