Clipsal - Max 4 Mini Neutral link 100 A 500 V 7 hole with cover front wiring Black

Clipsal - Max 4 Mini Neutral link 100 A 500 V 7 hole with cover front wiring Black

Item Number: L7

This Clipsal MAX9 product is a black mini neutral link with a cover and 7 mounting holes with a front wiring. The Ue rated operational voltage is 500V. The In rated current is 100A.

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range

MAX9

Product brand

Clipsal

Range of product

Blue Point

Product or component type

neutral link

Physical

[in] rated current

100 A

[ue] rated operational voltage

500 V

Connector type

screw terminals

Number of poles

1

Reach regulation

Reference contains Substances of Very High Concern above the threshold

Eu rohs directive

Compliant with Exemptions

Mercury free

Yes

Rohs exemption information

Yes

China rohs regulation

Product out of China RoHS scope. Substance declaration for your information

Environmental disclosure

ENVPEP121019EN

Circularity profile

N/A

Others

Package 1 bare product quantity

1

Cable cross section

16 mm²

Number of mounting holes

7

Unit type of package 1

PCE

Number of units in package 1

1

Package 1 height

5.2 cm

Package 1 width

4.7 cm

Package 1 length

6.5 cm

Package 1 weight

64.0 g

Take-back

No

Product contributes to saved and avoided emissions

No

Removable battery

N/A
Show all specifications

Frequently Asked Questions

hide show

Does 5041NMML/5041NMS come with a push button assembly Blank?

 

5041NMML/5041NMS - doesn’t come with a push button assembly Blank
1

 

25041NMML Clipsal 40 Series C-Bus Master Module

 

 

35041NMS-Clipsal C-Bus 40 SERIES Slave Push Button Mech

 

 

5041NMS does not  come with a push button cap,  need to purchase separately

 

 

440APB(Standard PushButton)

 5 S40APB(style color range)  or
 6E40APB (essence style range)- for marking then it will be a special order

 
 

What can cause a ILF fault on the ATV71 drive with an VW3A3501 CIC card installed?

Issue:
ILF fault on the ATV71 with an  VW3A3501 CIC card installed.

Product line:
Altivar ATV71

Environment:
All models, all serial numbers 

Cause:
If the CIC card is missing the external +24vdc pwr supply the drive will trigger an ILF fault after 1 sec of being powered up.      

Resolution:
Per the CIC installation manual document, atv71_controller_inside_EN_V3 page 10, it is recommended to add an external power supply part number ABL7RE2402 to the controller inside cards +24vdc and com terminals to resolve issue.
 

How can we set the time and date in Modicon PL7 Premium CPU.

The procedure for setting the time and date in Modicon PL7 Premium CPU is as follows:

1. Open the PL7 Pro project.
 
2. Make a configuration by selecting PL7 Pro Premium PLC-TSXP572623. Verify this configuration.
 
3. Go online with PLC. Open the Debug screen of Premium PLC. Enter the date and time as per requirement.
 
4. Click on OK then update tab. It will set the date & time of PLC's real time clock as per your requirement.
 
Refer below snapshot showing the date and time fields.
 

How do you fix Socket error when enabling Dali Mapping in PICED?

DALI mapping

5080CTC Colour V2/3 touch screen controlling dalicontrol

 

 

If having socket error when enabling Dali Mapping

Go into window services and stop Dalibuilding scheduler


 

How to backup and restore Dalibuilding database?

Require SQL Server Management Studio backup and Attach Databases in Management Studio

To Backup > Right click on the database and select Task > Backup

Select Location and Ok .BAK file

 

to Restore, Right click > Restore Database

Choose Device > click the three dot

Then Click Add > 

 

Select the backup .BAK then Ok > Ok then OK

How can I get Device Information from a SCADAPack into GeoSCADA?

Summary
Device Information  can be read into Geo SCADA using the feature "Device Attributes" at startup. This is more efficient than using String Points, as the data is read once and not polled continuously.
 
Issue
RemoteConnect has System Data such as Device Information (SYS_DEVICE), Capacity Statistics (SYS_CAPACITY), System Clock (SYS_CLOCK) available which can be viewed in RemoteConnect in an online object browser. Items that are UINT, DINT can be read into Geo SCADA. But RemoteConnect R2.5.1 (released 01/2021) does not support String Points, so Device Information can't be read this way for now. A future release is expected to have this enhancement; check the Release Notes.

Resolution
Because x70 (or SPE) are level 4 DNP3 devices, they support a feature called "Device Attributes". In Geo SCADA (ClearSCADA) there is a drop down menu "Read Device Attributes". Select "When Starting Comms" to collect the Device Information at start-up. This is a much more efficient way to get the data than using string points, because they are polled on start-up and do not come back in every string poll.

How to get system data from RC into GS.jfif

When DNP3 "Read Device Attributes" on start up is selected, then certain attributes can be retrieved via Geo SCADA such as firmware version, serial number, device type, manufacturer. You cannot get bootloader information though. You can use OPC tags to place it in a mimic. 

string data in GeoSCADA.jfif

string data on a mimic2.jpg

RemoteConnect Logic Editor:
In Logic a user can use the system function blocks. In particular PRJ_Vers. This shows build numbers and project name.

project version in logic editor.jpg

What are the part number and driver for the serial port (9-Pin D-Shell) to USB converter for Modicon Quantum PLC.

The part no. of the Schneider USB to RS232 Converter is TSXCUSB232 Refer the attachment for the TSXUSB232 documentation.
 
Use the standard Schneider UniTelway / Modbus drivers provided with software (Unity, PL7-Pro,) or by CD (TLX CDDRV20M).

What are the coil voltage codes for the LC1D09 / LC2D09 through LC1D38 / LC2D38 TeSys contactors?

Issue:
Coil Voltage suffixes for Tesys D contactors LC*D 09/38

Product Line:
IEC Contactors and Starters

Environment:
Tesys D contactors

Cause:
Selection

Resolution:
The following lists the more common voltage suffix codes for these product lines.  For a more comprehensive list and to determine compatibility with a given product, refer to the catalog below.

AC Volts ___Code     AC Volts ___Code
12 ___ J7                   208 ___ LE7
21 ___ Z7                   220 ___ M7
24 ___ B7                  230 ___ P7
32 ___ C7                  240 ___ U7
36 ___ CC7               277 ___ W7
42 ___ D7                  380 ___ Q7
48 ___ E7                   400 ___ V7
60 ___ EE7                415 ___ N7
100 ___ K7                440 ___ R7
110 ___ F7                480 ___ T7
115 ___ FE7              575 ___ SC7
120 ___ G7                600 ___ X7
127 ___ FC7              690 ___ Y7
200 ___ L7                
               
Standard Coil                Low Consumption
DC Volts ___Code          DC Volts ___Code
12 ___ JD                           5 ___ AL
24 ___ BD                         12 ___ JL
36 ___ CD                         20 ___ ZL
48 ___ ED                         24 ___ BL
60 ___ ND                         48 ___ EL
72 ___ SD                         72 ___ SL
110 ___ FD                       96 ___ DL
125 ___ GD                     110 ___ FL
220 ___ MD                    220 ___ ML
250 ___ UD                     250 ___ UL
440 ___ RD                

What is the operating temperature range on the ABL8WPS24200 and ABL8WPS24400 power supplies?

Issue:
Needs environmental data for ABL8WPS24200 and ABL8WPS24400.

Product Line:
Relays and Timers

Environment:
ABL Phaseo Power Supplies
 
Resolution:
Per expanded catalog DIA3ED207041EN-US, page 30, "-13°F to 140°F with derating from 122 °F or  (-25 to +60 derating from 50°C)".

What is the replacement AC coil for CAD32 and CAD50 relay?

Issue:
AC coil replacement for CAD32 and CAD50

Product Line:
Relays

Environment:
Tesys CAD Control Relays

Cause:
Product selection

Resolution:
Volt = coil part number
12 = LXD1J7
21 = LXD1Z7
24 = LXD1B7
32 = LXD1C7
36 = LXD1CC7
42 = LXD1D7
48 = LXD1E7
60 = LXD1EE7
100 = LXD1K7
110 = LXD1F7
115 = LXD1FE7
120 = LXD1G7
127 = LXD1FC7
200 = LXD1L7
208 = LXD1LL7
220/230 = LXD1M7
230 595 21 LXD1P7
230/240 = LXD1U7
277 781 30 LXD1W7
380/400 = LXD1Q7
400 = LXD1V7
415 = LXD1N7
440 = LXD1R7
480 = LXD1T7
600 = LXD1X7
690 = LXD1Y7

 

How can I save the public variables of a DFB with PL7-PRO?

The public variables of a DFB can be modified by program or with animation tables. When reloading programs, these public variables return to the initialization values defined in the DFB editor. To retain the modified values, the S box of the variables concerned must be checked (in the DFB editor) and system bit %S94 set to 1. The public variables are then saved.