TeSys GV4 Motor circuit breaker TeSys GV4, 3P, 115A, Icu 25kA, magnetic, EverLink terminals
Item Number: GV4L115B
Datasheet
Barcode
| Qty | UoM | EAN | Colour |
|---|---|---|---|
| - | |||
| - | |||
| - |
Barcode
| Qty | UoM | EAN | Colour |
|---|---|---|---|
| 1 | PCE | 3606481309501 | - |
Specifications
Design
| Range | TeSys Deca |
|---|---|
| Range of product | TeSys GV4 |
| Product or component type | motor circuit breaker |
| Device application | motor protection |
| Warranty | 18 months |
Physical
| Control type | rotary handle |
|---|---|
| [in] rated current | 115 A |
| [ue] rated operational voltage | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
| Mechanical durability | 40000 cycles |
| Electrical durability |
|
| Connections - terminals |
|
| Height | 155 mm |
| Width | 81 mm |
| Depth | 165 mm |
| Net weight | 1.65 kg |
| Standards |
|
| Product certifications |
|
| Climatic withstand | conforming to IACS E10 |
| Ik degree of protection | IK07 conforming to IEC 62262 |
| Ip degree of protection | IP40 conforming to IEC 60529 |
| Ambient air temperature for storage | -50...85 °C |
| Ambient air temperature for operation | -25...70 °C |
| Reach free of svhc | Yes |
| Toxic heavy metal free | Yes |
| Mercury free | Yes |
| Rohs exemption information | Yes |
| Environmental disclosure | ENVPEP1704004EN |
| Reach regulation | Free of Substances of Very High Concern above the threshold |
| China rohs regulation | Product out of China RoHS scope |
| Eu rohs directive | Compliant |
| California proposition 65 | WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov |
Others
| Life cycle assessment data | Yes |
|---|---|
| Substance regulation data deliverable | Yes |
| Package 1 bare product quantity | 1 |
| Average percentage of recycled plastic content | 0 % |
| At least in Europe | |
| Legacy weee scope | In |
| Warranty duration(in months) bmecat | 18 |
| Weee label | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
| Weee applicability | Finished product |
| Device short name | GV4L |
| Product name | TeSys GV4 |
| Trip unit technology |
|
| Poles description | 3P |
| Utilisation category |
|
| Operating position | any position |
| Motor power kw |
|
| Breaking capacity |
|
| Magnetic tripping current | 690...1610 A |
| [ui] rated insulation voltage | 800 V AC 50/60 Hz conforming to IEC 60947-2 |
| [ith] conventional free air thermal current | 115 A conforming to IEC 60947-4-1 |
| [uimp] rated impulse withstand voltage | 8 kV conforming to IEC 60947-2 |
| Power dissipation per pole | 6.1 W |
| Maximum operating rate | 25 cyc/h |
| Rated duty | continuous conforming to IEC 60947-4-1 |
| Direct connector | without |
| Tightening torque |
|
| Mechanical robustness |
|
| Suitability for isolation | yes conforming to IEC 60947-1 |
| Pollution degree | 3 |
| Fire resistance | 960 °C conforming to IEC 60695-2-11 |
| Operating altitude | 5000 m |
| Unit type of package 1 | PCE |
| Number of units in package 1 | 1 |
| Package 1 height | 10.500 cm |
| Package 1 width | 20.800 cm |
| Package 1 length | 22.000 cm |
| Package 1 weight | 1.834 kg |
| Unit type of package 2 | S03 |
| Number of units in package 2 | 3 |
| Package 2 height | 30.000 cm |
| Package 2 width | 30.000 cm |
| Package 2 length | 40.000 cm |
| Package 2 weight | 5.879 kg |
| Green premium status for reporting | Green Premium product |
| Total lifecycle carbon footprint | 115 kg CO2 eq. |
| Carbon footprint of the manufacturing phase [a1 to a3] | 11.889032401199032 |
| Carbon footprint of the manufacturing phase [a1 to a3] | 12 kg CO2 eq. |
| Carbon footprint of the distribution phase [a4] | 0.502764933926811 |
| Carbon footprint of the distribution phase [a4] | 0.5 kg CO2 eq. |
| Carbon footprint of the installation phase [a5] | 0.4480353851071321 |
| Carbon footprint of the installation phase [a5] | 0.4 kg CO2 eq. |
| Carbon footprint of the use phase [b2, b3, b4, b6] | 98.55743478260871 |
| Carbon footprint of the use phase [b2, b3, b4, b6] | 99 kg CO2 eq. |
| Sustainable packaging | Yes |
| Carbon footprint of the end-of-life phase [c1 to c4] | 4.051351533859914 |
| Carbon footprint of the end-of-life phase [c1 to c4] | 4 kg CO2 eq. |
| Pvc free | Yes |
| Halogen-free status | Halogen free plastic parts product |
| Energy efficiency optimized | False |
| F-gas free | N/A |
| Updatability | N/A |
| Take-back | No |
| Product contributes to saved and avoided emissions | No |
| Removable battery | N/A |
| Total lifecycle carbon footprint | 115.4486190367016 |
| Average percentage of recycled metal content | 0 % |
| Packaging made with recycled cardboard | Yes |
| Packaging without single use plastic | Yes |
| Scip number | 1b259a2c-3a3c-401a-acdd-f0837efd4018 |
| China rohs label | 1 |
| Halogen-free status | Halogen free plastic parts product |
| Pvc free | Yes |
| End of life manual availability | ENVEOLI1704004EN |
| Take-back | No |
| Weee label | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
| Warranty (in months) | 18 |
Documents & downloads
-
All
-
CAD Files and Packs
-
Technical Data Catalogues
-
Environmental Disclosure
-
End of Life Manual
-
Technical illustration
-
Certificates (MSDS)
-
Declaration of Conformity
-
eTechPub
-
Declaration of Conformity (Sustainability)
TeSys - Catalog 2026 - Innovative and connected solutions for motor starters
VERSION
17.0
DATE
11 May 2026
REVISION
17.0
Discover the catalog of Altivar HVAC ATH600 variable speed drives
VERSION
1.0
DATE
04 May 2026
REVISION
1.0
Discover the catalog of Easy Altivar 610 variable speed drives range.
VERSION
14.2
DATE
16 Sep 2025
REVISION
14.2
Discover catalog for Altivar Soft Starter ATS480
VERSION
1.2
DATE
16 Sep 2025
REVISION
1.2
Discover catalog for Altivar Soft Starter ATS490
VERSION
1.0
DATE
23 May 2025
REVISION
1.0
Discover catalog for Altivar Soft Starter ATS430
VERSION
1.0
DATE
18 Apr 2025
REVISION
1.0
TA59418_B0-EU-MR-BV-GV4L-LE
VERSION
1.0
DATE
01 Apr 2026
REVISION
1.0
TACBV-49777_B0-GV4P-PE-PEM-L-LE_-10-09-2025-valid-10-09-2030
VERSION
1.0
DATE
19 Nov 2025
REVISION
1.0
CCC_TeSys GV_GV4L&GV4LE
VERSION
1.0
DATE
25 Nov 2024
REVISION
1.0
CB_Certificate_TeSys GV4L&GV4LE&GV4P&GV4PE&GV4PEM
VERSION
2.0
DATE
29 Jul 2024
REVISION
2.0
GV4L115B EU RoHS Directive
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
GV4L115B EU RoHS Directive
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
GV4L115B EU RoHS Directive
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
GV4L115B EU RoHS Directive
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
GV4L115B EU RoHS Directive
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
GV4L115B EU RoHS Directive
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
GV4L115B REACh Regulation
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
GV4L115B REACh Regulation
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
GV4L115B REACh Regulation
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
GV4L115B REACh Regulation
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
GV4L115B REACh Regulation
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
GV4L115B REACh Regulation
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
Related products
DISCONTINUED
LRD4367
TeSys LR.D Thermal Overload Relays
TeSys Deca, 95...120A, class 10A, lug clamps
DISCONTINUED
LRD4365
TeSys LR.D Thermal Overload Relays
TeSys Deca, 80...104A, class 10A, lug clamps
Recently viewed
DISCONTINUED
GV4L115B
TeSys GV4 Motor circuit breaker
TeSys GV4, 3P, 115A, Icu 25kA, magnetic, EverLink terminals
DISCONTINUED
NSYTRALVR162
Linergy Reduction Bridge for Connecting 16mm² Screw Terminal to 2
5/4mm² Sprin
DISCONTINUED
16/30L162/4
Metal Plate Series Labelled Switch Plate
16 Gang, Stainless Steel, 4 Rows of 4
DISCONTINUED
ZB4BW0B35
Harmony XB4 Light block with body fixing collar
metal, green, integral LED, 24V AC DC, 1NO+1NC
DISCONTINUED
LC1D50AK7
TeSys D Contactor
TeSys Deca, 3P(3 NO), AC-3/AC-3e, 0 to 440V, 50A, 100VAC 50/60Hz coil
DISCONTINUED
GV2P16
TeSys GV2 Motor circuit breaker
TeSys Deca, 3P, 9 to 14A, thermal magnetic, screw clamp terminals, rotary handle
DISCONTINUED
LC1D1156N5
TeSys D Contactor
TeSys Deca, 3P(3NO), AC-3/AC-3e, <=440V, 115A, 415V AC 50 Hz coil, lugs/bars terminals
DISCONTINUED
GB2CD07
TeSys GB2 Circuit breaker
1P+N, 2A, Icu 15kA at 240V, Thermal magnetic, DIN rail mounted
DISCONTINUED
ZB4BZ105
Harmony XB4 Single contact block with body fixing collar
metal, screw clamp terminal, 1NO+1NC
DISCONTINUED
GV4P07N
TeSys GV4 Motor circuit breaker
TeSys GV4, 3P, 7A, Icu 50kA, thermal magnetic, Everlink terminals
DISCONTINUED
GV4LE50B6
TeSys GV4 Motor circuit breaker
TeSys GV4, 3P, 50A, Icu 25kA, magnetic, lugs terminals
DISCONTINUED
NSYTRACEP24
Linergy Partial Cover plate
Linergy TR, 2 level, 4 points, for screw terminals NSYTRV24D, NSYTR, grey, Set of 50
DISCONTINUED
56PEK32
Clipsal - 56 Series Pendant Outlet
IP66, Switched Pendant Outlet Kit Moulded 32mm Entry
DISCONTINUED
NSYTRALV102
Linergy Reduction Bridge for Connecting 10mm² to 2
5/4mm² Screw Terminal Block
DISCONTINUED
GV4L115B
TeSys GV4 Motor circuit breaker
TeSys GV4, 3P, 115A, Icu 25kA, magnetic, EverLink terminals
DISCONTINUED
NSYTRALVR162
Linergy Reduction Bridge for Connecting 16mm² Screw Terminal to 2
5/4mm² Sprin
DISCONTINUED
16/30L162/4
Metal Plate Series Labelled Switch Plate
16 Gang, Stainless Steel, 4 Rows of 4
DISCONTINUED
ZB4BW0B35
Harmony XB4 Light block with body fixing collar
metal, green, integral LED, 24V AC DC, 1NO+1NC
DISCONTINUED
LC1D50AK7
TeSys D Contactor
TeSys Deca, 3P(3 NO), AC-3/AC-3e, 0 to 440V, 50A, 100VAC 50/60Hz coil
DISCONTINUED
GV2P16
TeSys GV2 Motor circuit breaker
TeSys Deca, 3P, 9 to 14A, thermal magnetic, screw clamp terminals, rotary handle
DISCONTINUED
LC1D1156N5
TeSys D Contactor
TeSys Deca, 3P(3NO), AC-3/AC-3e, <=440V, 115A, 415V AC 50 Hz coil, lugs/bars terminals
DISCONTINUED
GB2CD07
TeSys GB2 Circuit breaker
1P+N, 2A, Icu 15kA at 240V, Thermal magnetic, DIN rail mounted
DISCONTINUED
ZB4BZ105
Harmony XB4 Single contact block with body fixing collar
metal, screw clamp terminal, 1NO+1NC
DISCONTINUED
GV4P07N
TeSys GV4 Motor circuit breaker
TeSys GV4, 3P, 7A, Icu 50kA, thermal magnetic, Everlink terminals
DISCONTINUED
GV4LE50B6
TeSys GV4 Motor circuit breaker
TeSys GV4, 3P, 50A, Icu 25kA, magnetic, lugs terminals
DISCONTINUED
NSYTRACEP24
Linergy Partial Cover plate
Linergy TR, 2 level, 4 points, for screw terminals NSYTRV24D, NSYTR, grey, Set of 50
DISCONTINUED
56PEK32
Clipsal - 56 Series Pendant Outlet
IP66, Switched Pendant Outlet Kit Moulded 32mm Entry
DISCONTINUED
NSYTRALV102
Linergy Reduction Bridge for Connecting 10mm² to 2
5/4mm² Screw Terminal Block