Browse all
Browse all

TeSys LR.D Thermal Overload Relays TeSys Deca, 95...120A, class 10A, lug clamps

Home ProductsIndustrialTeSysThermal Overload Relays

TeSys LR.D Thermal Overload Relays TeSys Deca, 95...120A, class 10A, lug clamps

Item Number: LRD4367

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range TeSys
Product or component type differential thermal overload relay
Product compatibility
  • LC1D150
  • LC1D115
Warranty 18 months

Physical

Mounting support
  • plate, with specific accessories
  • rail, with specific accessories
  • under contactor
[ue] rated operational voltage 1000 V AC 0...400 Hz for power circuit conforming to IEC 60947-4-1
Control type
  • red push-button: stop
  • blue push-button: reset
Connections - terminals
  • power circuit: screw clamp terminals 1 cable(s) 4-35 mm² flexible with cable end
  • control circuit: screw clamp terminals 2 cable(s) 1-2.5 mm² flexible without cable end
  • control circuit: screw clamp terminals 2 cable(s) 1-2.5 mm² flexible with cable end
  • control circuit: screw clamp terminals 2 cable(s) 1-2.5 mm² solid without cable end
  • power circuit: screw clamp terminals 1 cable(s) 4-50 mm² flexible without cable end
  • power circuit: screw clamp terminals 1 cable(s) 4-50 mm² solid without cable end
Depth 132 mm
Net weight 0.9 kg
Climatic withstand conforming to IACS E10
Ip degree of protection IP20 conforming to IEC 60529
Ambient air temperature for operation -20...60 °C without derating conforming to IEC 60947...4-1
Ambient air temperature for storage -60...70 °C
Standards
  • EN/IEC 60947-4-1
  • EN/IEC 60947-5-1
  • UL 60947-4-1
  • UL 60947-5-1
  • CSA C22.2 No 60947-4-1
  • CSA C22.2 No 60947-5-1
  • GB/T 14048.4
  • GB/T 14048.5
  • EN 50495
Product certifications
  • IEC
  • UL
  • CSA
  • CCC
  • EAC
  • ATEX INERIS
Reach free of svhc Yes
Toxic heavy metal free Yes
Mercury free Yes
Rohs exemption information Yes
Environmental disclosure ENVPEP1101001EN
Reach regulation Free of Substances of Very High Concern above the threshold
China rohs regulation Product out of China RoHS scope
Eu rohs directive Compliant
California proposition 65 WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov

Others

Life cycle assessment data Yes
Substance regulation data deliverable Yes
Average percentage of recycled plastic content 0 %
Package 3 bare product quantity 80
At least in Europe
Warranty duration(in months) bmecat 18
Weee label The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
Package 2 bare product quantity 10
Package 1 bare product quantity 1
Legacy weee scope In
Product name
  • TeSys LRD
  • TeSys Deca
Device short name LRD
Relay application motor protection
Network type
  • AC
  • DC
Thermal overload class class 10A conforming to IEC 60947-4-1
Thermal protection adjustment range 95...120 A
[ui] rated insulation voltage
  • power circuit: 1000 V conforming to IEC 60947-4-1
  • power circuit: 600 V conforming to CSA
  • power circuit: 600 V conforming to UL
Network frequency 0...400 Hz
Tripping threshold 1.14 +/- 0.06 Ir conforming to IEC 60947-4-1
Auxiliary contact composition 1 NO + 1 NC
[ith] conventional free air thermal current 5 A for signalling circuit
Permissible current
  • 0.06 A at 440 V DC-13 for signalling circuit
  • 0.12 A at 600 V AC-15 for signalling circuit
Associated fuse rating
  • 4 A gG for signalling circuit
  • 4 A BS for signalling circuit
[uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-1
Phase failure sensitivity tripping current 130 % of Ir on two phase, the last one at 0
Temperature compensation -20...60 °C
Tightening torque
  • control circuit: 1.7 N.m - on screw clamp terminals
  • power circuit: 9 N.m - on screw clamp terminals
Compatibility code LRD
Flame retardance V1 conforming to UL 94
Mechanical robustness
  • vibrations: 6 Gn conforming to IEC 60068-2-6
  • shocks: 15 Gn for 11 ms conforming to IEC 60068-2-7
Dielectric strength 2.2 kV at 50 Hz conforming to IEC 60947-1
Unit type of package 1 PCE
Number of units in package 1 1
Package 1 height 15.500 cm
Package 1 width 13.500 cm
Package 1 length 11.000 cm
Package 1 weight 830.000 g
Unit type of package 2 S03
Number of units in package 2 10
Package 2 height 30.000 cm
Package 2 width 30.000 cm
Package 2 length 40.000 cm
Package 2 weight 8.880 kg
Unit type of package 3 P06
Number of units in package 3 80
Package 3 height 75.000 cm
Package 3 width 60.000 cm
Package 3 length 80.000 cm
Package 3 weight 81.324 kg
Green premium status for reporting Green Premium product
Total lifecycle carbon footprint 8 kg CO2 eq.
Carbon footprint of the manufacturing phase [a1 to a3] 4.305506594796376
Carbon footprint of the manufacturing phase [a1 to a3] 4 kg CO2 eq.
Carbon footprint of the distribution phase [a4] 0.16290861781894878
Carbon footprint of the distribution phase [a4] 0.2 kg CO2 eq.
Carbon footprint of the installation phase [a5] 0.08722167141519573
Carbon footprint of the installation phase [a5] 0.1 kg CO2 eq.
Carbon footprint of the use phase [b2, b3, b4, b6] 1.8963357840065684
Carbon footprint of the use phase [b2, b3, b4, b6] 2 kg CO2 eq.
Sustainable packaging Yes
Carbon footprint of the end-of-life phase [c1 to c4] 1.2779284715732444
Carbon footprint of the end-of-life phase [c1 to c4] 1 kg CO2 eq.
F-gas free N/A
Take-back No
Product contributes to saved and avoided emissions No
Removable battery N/A
Total lifecycle carbon footprint 7.729901139610334
Average percentage of recycled metal content 0 %
Packaging made with recycled cardboard Yes
Packaging without single use plastic Yes
China rohs label 1
End of life manual availability ENVEOLI1101001
Take-back No
Weee label The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
Warranty (in months) 18

Documents & downloads

Filter items
  • All

  • CAD Files and Packs

  • Technical Data Catalogues

  • Environmental Disclosure

  • End of Life Manual

  • Installation Instruction

  • Certificates (MSDS)

  • Declaration of Conformity

  • Declaration of Conformity (Sustainability)

Important: Some software files may need a mySchneider or Club login to download.