TeSys GV2 Motor circuit breaker TeSys Deca, 3P, 20 to 25A, thermal magnetic, screw clamp terminals, rotary handle
Item Number: GV2P22
TeSys GV motor circuit breaker, 3 poles (3P), 25A/690V, for 3-phase motor applications 11kW@400V. It provides a thermal-magnetic protection with a thermal setting range 20-25A, magnetic tripping at 13xIn, high breaking capacity Icu 50kA@400V. Connection by screw clamp terminals. Start-stop control by rotary knob guaranteed for 100 000 cycles AC-3. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX),
Datasheet
Barcode
| Qty | UoM | EAN | Colour |
|---|---|---|---|
| - | |||
| - | |||
| - |
Barcode
| Qty | UoM | EAN | Colour |
|---|---|---|---|
| 1 | PCE | 3389110213539 | - |
Specifications
Design
| Range | TeSys Deca |
|---|---|
| Range of product |
|
| Product or component type | motor circuit breaker |
| Device application | motor protection |
| Warranty | 18 months |
Physical
| Control type | rotary handle |
|---|---|
| [in] rated current | 25 A |
| [ue] rated operational voltage | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
| Mechanical durability | 100000 cycles |
| Electrical durability |
|
| Connections - terminals |
|
| Fixing mode |
|
| Mounting position |
|
| Width | 45 mm |
| Height | 89 mm |
| Depth | 97 mm |
| Standards |
|
| Product certifications |
|
| Ik degree of protection | IK04 |
| Ip degree of protection | IP20 conforming to IEC 60529 |
| Climatic withstand | conforming to IACS E10 |
| Ambient air temperature for storage | -40...80 °C |
| Ambient air temperature for operation | -20...60 °C |
| Mercury free | Yes |
| Rohs exemption information | Yes |
| Environmental disclosure | ENVPEP2211002EN |
| Reach regulation | Reference contains Substances of Very High Concern above the threshold |
| China rohs regulation | Product out of China RoHS scope |
| Eu rohs directive | Compliant By Exemption |
| California proposition 65 | WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov |
Others
| Legacy weee scope | In |
|---|---|
| Substance regulation data deliverable | Yes |
| Life cycle assessment data | Yes |
| Package 1 bare product quantity | 1 |
| Package 2 bare product quantity | 20 |
| Package 3 bare product quantity | 320 |
| Average percentage of recycled plastic content | 0 % |
| At least in Europe | |
| Warranty duration(in months) bmecat | 18 |
| Weee label | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
| Product name | TeSys GV2 |
| Device short name | GV2P |
| Trip unit technology | thermal-magnetic |
| Poles description | 3P |
| Network type | AC |
| Utilisation category |
|
| Network frequency | 50/60 Hz conforming to IEC 60947-2 |
| Motor power kw |
|
| Breaking capacity |
|
| [ics] rated service short-circuit breaking capacity |
|
| Thermal protection adjustment range | 20...25 A conforming to IEC 60947...2 |
| Magnetic tripping current | 388.3...388.3 A |
| [ith] conventional free air thermal current | 25 A conforming to IEC 60947-2 |
| [ui] rated insulation voltage | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
| [uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947-2 |
| Phase failure sensitivity | yes conforming to IEC 60947-4-1 |
| Suitability for isolation | yes conforming to IEC 60947-1 |
| Power dissipation per pole | 2.5 W |
| Maximum operating rate | 25 cyc/h |
| Rated duty | uninterrupted conforming to IEC 60947-4-1 |
| Tightening torque | 1.7 N.m - on screw clamp terminal |
| Compatibility code | GV2P |
| Fire resistance | 960 °C conforming to IEC 60695-2-11 |
| Mechanical robustness |
|
| Operating altitude | <= 2000 m |
| Unit type of package 1 | PCE |
| Number of units in package 1 | 1 |
| Package 1 height | 4.800 cm |
| Package 1 width | 9.500 cm |
| Package 1 length | 10.000 cm |
| Package 1 weight | 332.000 g |
| Unit type of package 2 | S02 |
| Number of units in package 2 | 20 |
| Package 2 height | 15.000 cm |
| Package 2 width | 30.000 cm |
| Package 2 length | 40.000 cm |
| Package 2 weight | 6.887 kg |
| Unit type of package 3 | P06 |
| Number of units in package 3 | 320 |
| Package 3 height | 75.000 cm |
| Package 3 width | 60.000 cm |
| Package 3 length | 80.000 cm |
| Package 3 weight | 118.192 kg |
| Green premium status for reporting | Green Premium product |
| Total lifecycle carbon footprint | 9 kg CO2 eq. |
| Carbon footprint of the manufacturing phase [a1 to a3] | 1.9174178745780381 |
| Carbon footprint of the manufacturing phase [a1 to a3] | 2 kg CO2 eq. |
| Carbon footprint of the distribution phase [a4] | 0.03925994933156967 |
| Carbon footprint of the distribution phase [a4] | 0 kg CO2 eq. |
| Carbon footprint of the installation phase [a5] | 0.028882284663263702 |
| Carbon footprint of the installation phase [a5] | 0 kg CO2 eq. |
| Carbon footprint of the use phase [b2, b3, b4, b6] | 6.5845 |
| Carbon footprint of the use phase [b2, b3, b4, b6] | 7 kg CO2 eq. |
| Sustainable packaging | No |
| Carbon footprint of the end-of-life phase [c1 to c4] | 0.8882217597579712 |
| Carbon footprint of the end-of-life phase [c1 to c4] | 0.9 kg CO2 eq. |
| F-gas free | N/A |
| Take-back | No |
| Product contributes to saved and avoided emissions | No |
| Removable battery | N/A |
| Total lifecycle carbon footprint | 9.458281868330843 |
| Average percentage of recycled metal content | 0 % |
| Packaging made with recycled cardboard | Yes |
| Packaging without single use plastic | Yes |
| Scip number | cd9afc97-b700-4c24-8c5a-04f31f2d7dd2 |
| China rohs label | 3 |
| End of life manual availability | ENVEOLI2211002 |
| Take-back | No |
| Weee label | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
| Warranty (in months) | 18 |
Documents & downloads
-
All
-
CAD Files and Packs
-
Technical Data Catalogues
-
End of Life Manual
-
Environmental Disclosure
-
Installation Instruction
-
Data Bulletin
-
Operating Manuals
-
Technical illustration
-
Technical Drawing
-
Certificates (MSDS)
-
Declaration of Conformity
-
Declaration of Conformity (Sustainability)
TeSys - Catalog 2026 - Innovative and connected solutions for motor starters
VERSION
17.0
DATE
11 May 2026
REVISION
17.0
Discover the catalog for Altivar Machine ATV320 variable speed drive
VERSION
11.0
DATE
07 Jan 2026
REVISION
11.0
TeSys Contactors for Railway Applications- Catalog 2025
VERSION
4.1
DATE
22 Mar 2025
REVISION
4.1
Discover the catalog for Altivar Solar Variable Speed Drives
VERSION
2.0
DATE
19 Jun 2024
REVISION
2.0
GV2 ME.. Motor circuit-breakers - IS on the box - Instruction Sheet
VERSION
3.0
DATE
02 Apr 2026
REVISION
3.0
GV2 P/L Motor circuit-breakers - Instruction Sheet
VERSION
1.0
DATE
19 Dec 2024
REVISION
1.0
GV2AP.. Fixing kit for door interlock mechanism for GV2 P/L
VERSION
2.1
DATE
29 Sep 2023
REVISION
2.1
ATEX Certificate TeSys GV2ME&GV2P
VERSION
1.0
DATE
14 May 2026
REVISION
1.0
BIS Licence L‑4100315872 – Product Certification.
VERSION
1.0
DATE
09 Apr 2026
REVISION
1.0
BIS for low volage switch gear and control gear part 2-circuit breakers GV2
VERSION
1.0
DATE
10 Feb 2026
REVISION
1.0
CSA Certificate_TeSys GV2ME&GV2RT&GV2P&GV2MC&GV2MP and GV2P Type E & GV2P combined with LC1D09-38 type F
VERSION
1.0
DATE
02 Feb 2026
REVISION
1.0
CB_Certificate_TeSys GV2ME&GV2RT&GV2P&GV2L&GV2LE
VERSION
1.0
DATE
15 Jan 2026
REVISION
1.0
DNV EU-RO-MR TA Certificate_GV2ME_GV2P_GV2L_GV2LE_GV2LM_GV2RT
VERSION
1.0
DATE
26 Dec 2025
REVISION
1.0
DNV Type Approval Certificate_GV2ME_GV2P_GV2L_GV2LE_GV2LM_GV2RT
VERSION
1.0
DATE
26 Dec 2025
REVISION
1.0
UL Certificate_TeSys GV2_GV2ME&GV2RT&GV2P&GV2L&GV2LE&GV2LM
VERSION
1.0
DATE
06 Nov 2025
REVISION
1.0
CCC_TeSys GV_GV2ME&GV2P&GV2L_Bangpoo
VERSION
1.0
DATE
14 Jul 2025
REVISION
1.0
CCC Certificate_TeSys GV_GV2ME&GV2RT&GV2P&GV2L&GV2LE_France
VERSION
1.0
DATE
31 Mar 2025
REVISION
1.0
Marine Type Approval Certificate_TeSys GV_GV2L&GV2ME&GV2P&GV2RT
VERSION
1.0
DATE
12 Nov 2024
REVISION
1.0
BV Type approval certificate_TeSys GV2ME&GV2RT&GV2P&GV2L&GV2LE
VERSION
1.0
DATE
15 Sep 2024
REVISION
1.0
UKCA Declaration TeSys GV_GV2ME_GV2P with ATEX
VERSION
1.0
DATE
14 May 2026
REVISION
1.0
EU Declaration TeSys GV2ME & GV2P with ATEX
VERSION
1.0
DATE
14 May 2026
REVISION
1.0
EU Declaration TeSys GV2ME&GV2RT&GV2P&GV2L&GV2LE&GV2LM
VERSION
2.0
DATE
06 May 2026
REVISION
2.0
UKCA Declaration TeSys GV2ME&GV2RT&GV2P&GV2L&GV2LE&GV2LM
VERSION
2.0
DATE
16 Apr 2025
REVISION
2.0
GV2P22 EU RoHS Directive
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
GV2P22 EU RoHS Directive
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
GV2P22 EU RoHS Directive
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
GV2P22 EU RoHS Directive
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
GV2P22 EU RoHS Directive
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
GV2P22 EU RoHS Directive
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
GV2P22 EU RoHS Directive
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
GV2P22 EU RoHS Directive
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
GV2P22 REACh Regulation
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
GV2P22 REACh Regulation
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
GV2P22 REACh Regulation
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
GV2P22 REACh Regulation
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
Related products
DISCONTINUED
LC1D25P7
TeSys D Contactor
3P(3 NO), AC-3/AC-3e, 0 to 440V, 25A, 230VAC 50/60Hz coil
DISCONTINUED
LC1D25BD
TeSys D Contactor
3P(3 NO), AC-3/AC-3e, 0 to 440V, 25A, 24VDC coil
DISCONTINUED
LC1D25B7
TeSys D Contactor
3P(3 NO), AC-3/AC-3e, 0 to 440V, 25A, 24VAC 50/60Hz coil
DISCONTINUED
LC1D25F7
TeSys D Contactor
3P(3 NO), AC-3/AC-3e, 0 to 440V, 25A, 110VAC 50/60Hz coil
DISCONTINUED
LC1D25E7
TeSys D Contactor
3P(3NO), AC-3/AC-3e, <=440V 25A, 48V AC coil
DISCONTINUED
LC1D25FD
TeSys D Contactor
3P(3 NO), AC-3/AC-3e, 0 to 440V, 25A, 110VDC coil
DISCONTINUED
LC1D25P7
TeSys D Contactor
3P(3 NO), AC-3/AC-3e, 0 to 440V, 25A, 230VAC 50/60Hz coil
DISCONTINUED
LC1D25B7
TeSys D Contactor
3P(3 NO), AC-3/AC-3e, 0 to 440V, 25A, 24VAC 50/60Hz coil
DISCONTINUED
LC1D25F7
TeSys D Contactor
3P(3 NO), AC-3/AC-3e, 0 to 440V, 25A, 110VAC 50/60Hz coil
DISCONTINUED
LC1D25FD
TeSys D Contactor
3P(3 NO), AC-3/AC-3e, 0 to 440V, 25A, 110VDC coil
Recently viewed
DISCONTINUED
GV2P22
TeSys GV2 Motor circuit breaker
TeSys Deca, 3P, 20 to 25A, thermal magnetic, screw clamp terminals, rotary handle
DISCONTINUED
LC1D32BNE
TeSys D Contactor
TeSys Deca, 3P(3 NO), AC-3/AC-3e, 0 to 440V, 32A, 24-60VAC/DC coil
DISCONTINUED
LX1D6D7
TeSys D Contactor Coil
LX1D6, 42 V AC 50/60 Hz for 80 & 95 A Contactor
DISCONTINUED
67P432/6
67 Series Plugs and Extension Sockets Plugs
380/415V, 32A, 6 Hour, 4 Pins
DISCONTINUED
LC1DT20ED
TeSys D Contactor
TeSys Deca, 4P(4 NO), AC-1, 0 to 440V, 20A, 48VDC standard coil
DISCONTINUED
LX1D6U6
TeSys D Contactor Coil
LX1D6, 240V AC 60 Hz for 80 & 95 A Contactor
DISCONTINUED
LC1D80U7
TeSys D Contactor
TeSys Deca, 3P(3NO), AC-3/AC-3e, <=440V, 80A, 240V AC 50/60Hz coil
DISCONTINUED
LC1D65AY7
TeSys D Contactor
3P(3 NO) , AC-3 , <= 440V, 65A, 690V AC 50/60 Hz coil
DISCONTINUED
GV2P22
TeSys GV2 Motor circuit breaker
TeSys Deca, 3P, 20 to 25A, thermal magnetic, screw clamp terminals, rotary handle
DISCONTINUED
LC1D32BNE
TeSys D Contactor
TeSys Deca, 3P(3 NO), AC-3/AC-3e, 0 to 440V, 32A, 24-60VAC/DC coil
DISCONTINUED
LX1D6D7
TeSys D Contactor Coil
LX1D6, 42 V AC 50/60 Hz for 80 & 95 A Contactor
DISCONTINUED
67P432/6
67 Series Plugs and Extension Sockets Plugs
380/415V, 32A, 6 Hour, 4 Pins
DISCONTINUED
LC1DT20ED
TeSys D Contactor
TeSys Deca, 4P(4 NO), AC-1, 0 to 440V, 20A, 48VDC standard coil
DISCONTINUED
LC1D80U7
TeSys D Contactor
TeSys Deca, 3P(3NO), AC-3/AC-3e, <=440V, 80A, 240V AC 50/60Hz coil
DISCONTINUED
LC1D65AY7
TeSys D Contactor
3P(3 NO) , AC-3 , <= 440V, 65A, 690V AC 50/60 Hz coil