TeSys D Contactor TeSys Deca, 3P(3NO), AC-3/AC-3e, <=440V, 115A, 440V AC 50/60Hz coil, lugs/bars terminals
Item Number: LC1D1156R7
Datasheet
Barcode
| Qty | UoM | EAN | Colour |
|---|---|---|---|
| - | |||
| - | |||
| - |
Barcode
| Qty | UoM | EAN | Colour |
|---|---|---|---|
| 1 | PCE | 3389110381511 | - |
Specifications
Design
| Range | TeSys |
|---|---|
| Range of product | TeSys Deca |
| Product or component type | contactor |
| Warranty | 18 months |
Physical
| [ue] rated operational voltage |
|
|---|---|
| [ie] rated operational current |
|
| Mechanical durability | 8 Mcycles |
| Electrical durability |
|
| Connections - terminals |
|
| Insulation resistance | > 10 MOhm for signalling circuit |
| Mounting support |
|
| Standards |
|
| Product certifications |
|
| Ip degree of protection | IP20 front face conforming to IEC 60529 |
| Climatic withstand |
|
| Height | 158 mm |
| Width | 120 mm |
| Depth | 136 mm |
| Net weight | 2.5 kg |
| Mercury free | Yes |
| Rohs exemption information | Yes |
| Environmental disclosure | ENVPEP0603001EN |
| Reach regulation | Reference contains Substances of Very High Concern above the threshold |
| China rohs regulation | Product out of China RoHS scope |
| Eu rohs directive | Compliant By Exemption |
Others
| Life cycle assessment data | Yes |
|---|---|
| Substance regulation data deliverable | Yes |
| Legacy weee scope | In |
| Average percentage of recycled plastic content | 0 % |
| Package 3 bare product quantity | 16 |
| Package 2 bare product quantity | 2 |
| Package 1 bare product quantity | 1 |
| At least in Europe | |
| Warranty duration(in months) bmecat | 18 |
| Weee label | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
| Device short name | LC1D |
| Contactor application |
|
| Utilisation category |
|
| Poles description | 3P |
| [uc] control circuit voltage | 440 V AC 50/60 Hz |
| Motor power kw |
|
| Motor power hp |
|
| Compatibility code | LC1D |
| Pole contact composition | 3 NO |
| Contact compatibility | M13 |
| Protective cover | with |
| [ith] conventional free air thermal current | 200 A (at 60 °C) for power circuit |
| Irms rated making capacity |
|
| Rated breaking capacity | 1100 A at 440 V for power circuit conforming to IEC 60947 |
| [icw] rated short-time withstand current |
|
| Associated fuse rating |
|
| Average impedance | 0.6 mOhm - Ith 200 A 50 Hz for power circuit |
| Power dissipation per pole |
|
| [ui] rated insulation voltage |
|
| Overvoltage category | III |
| Pollution degree | 3 |
| [uimp] rated impulse withstand voltage | 8 kV conforming to IEC 60947 |
| Safety reliability level |
|
| Control circuit type | AC at 50/60 Hz |
| Coil technology | built-in bidirectional peak limiting diode suppressor |
| Control circuit voltage limits |
|
| Inrush power in va |
|
| Hold-in power consumption in va |
|
| Heat dissipation | 3...8 W at 50/60 Hz |
| Operating time |
|
| Maximum operating rate | 2400 cyc/h at 60 °C |
| Tightening torque |
|
| Auxiliary contact composition | 1 NO + 1 NC |
| Auxiliary contacts type |
|
| Signalling circuit frequency | 25...400 Hz |
| Minimum switching voltage | 17 V for signalling circuit |
| Minimum switching current | 5 mA for signalling circuit |
| Non-overlap time |
|
| Protective treatment | TH conforming to IEC 60068-2-30 |
| Permissible ambient air temperature around the device |
|
| Operating altitude | 0...3000 m |
| Fire resistance | 850 °C conforming to IEC 60695-2-1 |
| Flame retardance | V1 conforming to UL 94 |
| Mechanical robustness |
|
| Unit type of package 1 | PCE |
| Number of units in package 1 | 1 |
| Package 1 height | 16.800 cm |
| Package 1 width | 20.800 cm |
| Package 1 length | 18.500 cm |
| Package 1 weight | 2.110 kg |
| Unit type of package 2 | S03 |
| Number of units in package 2 | 2 |
| Package 2 height | 30 cm |
| Package 2 width | 30 cm |
| Package 2 length | 40 cm |
| Package 2 weight | 4.640 kg |
| Unit type of package 3 | P06 |
| Number of units in package 3 | 16 |
| Package 3 height | 75.000 cm |
| Package 3 width | 80.000 cm |
| Package 3 length | 60.000 cm |
| Package 3 weight | 45.120 kg |
| Green premium status for reporting | Green Premium product |
| Total lifecycle carbon footprint | 109 kg CO2 eq. |
| Carbon footprint of the manufacturing phase [a1 to a3] | 22.22881266064238 |
| Carbon footprint of the manufacturing phase [a1 to a3] | 22 kg CO2 eq. |
| Carbon footprint of the distribution phase [a4] | 0.7508929239734572 |
| Carbon footprint of the distribution phase [a4] | 0.8 kg CO2 eq. |
| Carbon footprint of the installation phase [a5] | 0.2654427709841767 |
| Carbon footprint of the installation phase [a5] | 0.3 kg CO2 eq. |
| Carbon footprint of the use phase [b2, b3, b4, b6] | 81.50132194244603 |
| Carbon footprint of the use phase [b2, b3, b4, b6] | 82 kg CO2 eq. |
| Sustainable packaging | No |
| Carbon footprint of the end-of-life phase [c1 to c4] | 4.425806016866926 |
| Carbon footprint of the end-of-life phase [c1 to c4] | 4 kg CO2 eq. |
| Pvc free | Yes |
| F-gas free | N/A |
| Take-back | No |
| Product contributes to saved and avoided emissions | No |
| Removable battery | N/A |
| Total lifecycle carbon footprint | 109.17227631491296 |
| Average percentage of recycled metal content | 0 % |
| Packaging made with recycled cardboard | Yes |
| Packaging without single use plastic | No |
| Scip number | a530c666-91dd-4119-8d61-f1c22a361ecb |
| Pvc free | Yes |
| End of life manual availability | ENVEOLI100405EN |
| Take-back | No |
| Weee label | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
| Warranty (in months) | 18 |
Documents & downloads
-
All
-
CAD Files and Packs
-
Technical Data Catalogues
-
End of Life Manual
-
Environmental Disclosure
-
Installation Instruction
-
Technical illustration
-
Certificates (MSDS)
-
Declaration of Conformity
-
Declaration of Conformity (Sustainability)
-
Product Change Notification
CSA Certificate_ TeSys D_LC1D115-150&LC2D115-150
VERSION
1.0
DATE
04 Sep 2025
REVISION
1.0
CCC_TeSys Deca_LC1D115-150&LC2D115-150
VERSION
1.0
DATE
18 Jun 2025
REVISION
1.0
UL_Certificate_TeSys D_LC1D115-150&LC2D115-150
VERSION
1.0
DATE
29 Feb 2024
REVISION
1.0
ABS Type Approval Certificate_TeSys D_LC1D115-150&LC2D115-150
VERSION
1.0
DATE
06 Oct 2022
REVISION
1.0
LC1D1156R7 EU RoHS Directive
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
LC1D1156R7 EU RoHS Directive
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
LC1D1156R7 EU RoHS Directive
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
LC1D1156R7 EU RoHS Directive
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
LC1D1156R7 EU RoHS Directive
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
LC1D1156R7 EU RoHS Directive
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
LC1D1156R7 REACh Regulation
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
LC1D1156R7 REACh Regulation
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
LC1D1156R7 REACh Regulation
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
LC1D1156R7 REACh Regulation
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
LC1D1156R7 REACh Regulation
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
LC1D1156R7 REACh Regulation
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
Recently viewed
DISCONTINUED
LC1D1156R7
TeSys D Contactor
TeSys Deca, 3P(3NO), AC-3/AC-3e, <=440V, 115A, 440V AC 50/60Hz coil, lugs/bars terminals
DISCONTINUED
SAU250H123DF
Acti9 SAU hybrid Chassis
250A, 3Ph, 6 poles 12mm and 6 poles 27mm for MCB and RCBO, dual feed
DISCONTINUED
LAD93217
TeSys D Kit for Star Delta Starter assembly of for 2 x Contactors LC1D25-D38 and star LC1D09-D18
with timer block
DISCONTINUED
NSYTBS191610HT
Thalassa ABS box
IP66 IK07 RAL7035 Int.H175W150D100 Ext.H193W164D105 Transp.cover H40
DISCONTINUED
GV4PEM12N
TeSys GV4 Motor circuit breaker
TeSys GV4, 3P, 12.5A, Icu 50kA, thermal magnetic multifunction, Everlink terminals
DISCONTINUED
ZB4BW0B15
Harmony XB4 Complete body/contact assembly and light block
metal, universal LED, body/fixing collar, 1NO + 1NC, 24V AC DC
DISCONTINUED
GV4P50N
TeSys GV4 Motor circuit breaker
TeSys GV4, 3P, 50A, Icu 50kA, thermal magnetic, Everlink terminals
DISCONTINUED
MX9K318PP
MAX9 New Energy Protection Kits with MAXBAR+
3P+N, 2 x 63A MCB, 40A RCBO, 1 x 25A MCB, 1 x 1P 32A MCB, NTB and Accessories
DISCONTINUED
1235NPT8
Clipsal - Cable Management Conduit Adaptor
Brass, 1-1/4-11-1/2 x M50x1.5, MNPT to Female
DISCONTINUED
56PEK25
Clipsal - 56 Series Pendant Outlet
IP66, Switched Pendant Outlet Kit Moulded 25mm Entry
DISCONTINUED
NSYTBS775
Thalassa ABS box
IP66 IK07 RAL7035 Int.H65W65D45 Ext.H74W74D56 Opaque cover H10
DISCONTINUED
LZ1H6X5FU
TeSys H Ultra compact starter
TeSys Hybrid, 3P, 500VAC, 3kW at 400V, 110 to 230VAC
DISCONTINUED
LC1D1156R7
TeSys D Contactor
TeSys Deca, 3P(3NO), AC-3/AC-3e, <=440V, 115A, 440V AC 50/60Hz coil, lugs/bars terminals
DISCONTINUED
SAU250H123DF
Acti9 SAU hybrid Chassis
250A, 3Ph, 6 poles 12mm and 6 poles 27mm for MCB and RCBO, dual feed
DISCONTINUED
LAD93217
TeSys D Kit for Star Delta Starter assembly of for 2 x Contactors LC1D25-D38 and star LC1D09-D18
with timer block
DISCONTINUED
NSYTBS191610HT
Thalassa ABS box
IP66 IK07 RAL7035 Int.H175W150D100 Ext.H193W164D105 Transp.cover H40
DISCONTINUED
GV4PEM12N
TeSys GV4 Motor circuit breaker
TeSys GV4, 3P, 12.5A, Icu 50kA, thermal magnetic multifunction, Everlink terminals
DISCONTINUED
ZB4BW0B15
Harmony XB4 Complete body/contact assembly and light block
metal, universal LED, body/fixing collar, 1NO + 1NC, 24V AC DC
DISCONTINUED
GV4P50N
TeSys GV4 Motor circuit breaker
TeSys GV4, 3P, 50A, Icu 50kA, thermal magnetic, Everlink terminals
DISCONTINUED
MX9K318PP
MAX9 New Energy Protection Kits with MAXBAR+
3P+N, 2 x 63A MCB, 40A RCBO, 1 x 25A MCB, 1 x 1P 32A MCB, NTB and Accessories
DISCONTINUED
1235NPT8
Clipsal - Cable Management Conduit Adaptor
Brass, 1-1/4-11-1/2 x M50x1.5, MNPT to Female
DISCONTINUED
56PEK25
Clipsal - 56 Series Pendant Outlet
IP66, Switched Pendant Outlet Kit Moulded 25mm Entry
DISCONTINUED
NSYTBS775
Thalassa ABS box
IP66 IK07 RAL7035 Int.H65W65D45 Ext.H74W74D56 Opaque cover H10
DISCONTINUED
LZ1H6X5FU
TeSys H Ultra compact starter
TeSys Hybrid, 3P, 500VAC, 3kW at 400V, 110 to 230VAC