Harmony Control Relays Modular 1 phase current Control Relay 5A, 2CO, 2…500mA, 24…240V AC DC

Home ProductsIndustrialHarmonyModular 1 phase current Control Relay

Harmony Control Relays Modular 1 phase current Control Relay 5A, 2CO, 2…500mA, 24…240V AC DC

Item Number: RM35JA31MW

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range of product Harmony Control Relays
Product or component type current control relay

Physical

Control type without test button
Connections - terminals screw connectors
[in] rated current 5 A
Electrical durability 100000 cycles
Mechanical durability 30000000 cycles
Standards IEC 60255-6
Product certifications
  • GL
  • CSA
  • GOST
  • UL
  • C-Tick
Marking
  • CE : EMC 89/336/EEC
  • CE : 73/23/EEC
Ambient air temperature for storage -40...70 °C
Ambient air temperature for operation -20...50 °C
Relative humidity 95 % at 55 °C conforming to IEC 60068...2-30
Ip degree of protection
  • IP20 (terminals) conforming to IEC 60529
  • IP30 (casing) conforming to IEC 60529
Insulation resistance > 500 MOhm at 500 V DC between supply and relay output conforming to IEC 60255-5
Connections - terminals
  • screw terminals, 1 x 0.5...1 x 4 mm² (20 AWG...11 AWG) solid without cable end
  • screw terminals, 2 x 0.5...2 x 2.5 mm² (20 AWG...14 AWG) solid without cable end
  • screw terminals, 1 x 0.2...1 x 2.5 mm² (24 AWG...12 AWG) flexible with cable end
  • screw terminals, 2 x 0.2...2 x 1.5 mm² (24 AWG...16 AWG) flexible with cable end
Local signalling
  • LED (green) for power ON
  • LED (yellow) for relay ON
Mounting support 35 mm symmetrical DIN rail conforming to IEC 60715
Width 35 mm
Net weight 0.13 kg
Mercury free Yes
Environmental disclosure ENVPEP1601004EN
Eu rohs directive Compliant By Exemption
California proposition 65 WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

Material

Contacts material cadmium free

Others

Legacy weee scope Out
Package 1 bare product quantity 1
Package 2 bare product quantity 48
Average percentage of recycled plastic content 0 %
At least in Europe
Weee label No
Relay type current control relay
Relay name RM35JA
Relay monitored parameters overcurrent and undercurrent control
Contacts type and composition 2 C/O
[uc] control circuit voltage 24...240 V
[us] rated supply voltage 24...240 V AC/DC 50/60 Hz, non self-powered
Supply voltage limits 20.4...264 V AC/DC
Maximum power consumption in va 3.5 VA AC
Maximum power consumption in w 0.6 W DC
Immunity to microbreaks 50 ms
Measurement range 2...500 mA AC/DC E2-M terminals
Maximum measuring cycle 30 ms measurement cycle as true rms value
Hysteresis 5...50 % of threshold setting
Repeat accuracy
  • +/- 0.5 % for input and measurement circuit
  • +/- 2 % for time delay
Measurement error
  • 0.05 %/°C with temperature variation
  • 1 by volt over the whole range with voltage variation
Time delay type
  • adjustable 0.3...30 s, 0 + 10 % Tt- time delay upon fault
  • adjustable 1...20 s, 0 + 10 % Ti- inhibition time delay upon startup
Reset time 1500 ms time delay
Run-up delay at power-up 0.3 s
Output contacts 2 C/O
Nominal output current 5 A
Maximum switching voltage 250 V AC
Switching capacity in va 1250 VA
Minimum switching current 10 mA at 5 V DC
Maximum switching current 5 A AC
Control circuit voltage limits - 15 % + 10 % Un
Control circuit frequency 40...70 Hz +/- 10 %
Resistance across terminals
  • 1 Ohm at E2-M terminals
  • 5 Ohm at E1-M terminals
  • 0.2 Ohm at E3-M terminals
Measurement accuracy +/- 10 % of the full scale value
Threshold setting 10...100 %
Insulation between supply and measurement
Functionality overcurrent or undercurrent in window mode
Compatibility code RM3
Electromagnetic compatibility
  • emission standard for industrial environments conforming to IEC 61000-6-4
  • emission standard for residential, commercial and light-industrial environments conforming to IEC 61000-6-3
  • immunity for industrial environments conforming to NF EN/IEC 61000-6-2
Pollution degree 3 conforming to IEC 60664-1
Overvoltage category III conforming to IEC 60664-1
Dielectric test voltage 2 kV, 1 min AC 50 Hz conforming to IEC 60255-5
[ui] rated insulation voltage 250 V conforming to IEC 60664-1
Operating position any position without derating
Tightening torque 0.6...1 N.m conforming to IEC 60947...1
Housing material polycarbonate
Safety reliability data
  • MTTFd = 296.8 years
  • B10d = 270000
Unit type of package 1 PCE
Number of units in package 1 1
Package 1 height 4.500 cm
Package 1 width 7.800 cm
Package 1 length 9.500 cm
Package 1 weight 138.000 g
Unit type of package 2 S03
Number of units in package 2 48
Package 2 height 30.000 cm
Package 2 width 30.000 cm
Package 2 length 40.000 cm
Package 2 weight 7.350 kg
Green premium status for reporting Green Premium product
Total lifecycle carbon footprint 42 kg CO2 eq.
Carbon footprint of the manufacturing phase [a1 to a3] 2.4586778537
Carbon footprint of the manufacturing phase [a1 to a3] 2 kg CO2 eq.
Carbon footprint of the distribution phase [a4] 0.0238468659
Carbon footprint of the distribution phase [a4] 0 kg CO2 eq.
Carbon footprint of the installation phase [a5] 0
Carbon footprint of the installation phase [a5] 0 kg CO2 eq.
Carbon footprint of the use phase [b2, b3, b4, b6] 39.7498772978
Carbon footprint of the use phase [b2, b3, b4, b6] 40 kg CO2 eq.
Sustainable packaging Yes
Carbon footprint of the end-of-life phase [c1 to c4] 0.0091526182
Carbon footprint of the end-of-life phase [c1 to c4] 0 kg CO2 eq.
Take-back No
Product contributes to saved and avoided emissions No
Removable battery N/A
Total lifecycle carbon footprint 42.2415546356
Average percentage of recycled metal content 0 %
Packaging made with recycled cardboard Yes
Packaging without single use plastic Yes
Scip number 5e3fdf99-611b-4d07-ad17-6eba84ab488b
End of life manual availability ENVEOLI1601004EN
Take-back No
Warranty (in months) 18

Documents & downloads

Filter items
  • All

  • CAD Files and Packs

  • Technical Data Catalogues

  • End of Life Manual

  • Environmental Disclosure

  • Installation Instruction

  • Technical illustration

  • Application Notes

  • eTechPub

  • Certificates (MSDS)

  • Declaration of Conformity

  • Declaration of Conformity (Sustainability)

Important: Some software files may need a mySchneider or Club login to download.