SpaceLogic C-Bus Switch Solis C, Wall Plate, A-Series, 1 Key Input Unit | Platinum Aluminium
Item Number: 5011PT
Specifications
Design
| Product brand | Schneider Electric |
|---|---|
| Range | SpaceLogic C-Bus |
| Product or component type | switch |
| Device application | control |
| Colour tint | white aluminium |
| Range of product | Solis C |
Physical
| Device presentation | complete product |
|---|---|
| Number of gangs | 1 gang |
| Control type | push-button |
| Provided equipment | fascia plate |
| [ue] rated operational voltage | 15...36 V DC |
| [in] rated current | 22 mA |
| Communication network type | C-Bus |
| Switch function |
|
| Local signalling | LED (red, green and blue) for status |
| Connections - terminals | terminal block - 0.2-1.3 mm² (24 AWG...16 AWG) |
| Mounting support | wall-mount |
| Fixing center | 84 mm |
| Width | 74 mm |
| Height | 148 mm |
| Depth | 27.5 mm |
| Net weight | 108.4 g |
| Product certifications |
|
| Environmental disclosure | ENVPEP2607013EN |
| Eu rohs directive | Compliant By Exemption |
Material
| Material | aluminium |
|---|
Documents & downloads
-
All
-
CAD Files and Packs
-
Product Brochures
-
Technical Data Catalogues
-
Installation Instruction
-
End of Life Manual
-
Environmental Disclosure
-
Operating Manuals
-
Declaration of Conformity (Sustainability)
-
Software - Release
Frequently Asked Questions
Wiser motion sensor – What is detection delay and how do I program it?
Hide ShowBe aware that changing the detection delay value can change the battery life of the product.
To explain how this works we will use 5 minutes detection delay as an example. When motion is detected the sensor sends the signal ‘occupied’ to the hub. If no more motion is detected within the 5 minutes the sensor will send the signal ‘unoccupied’. If there was motion detected during the 5 minutes the 5 minutes will restart again. This will continue restarting until no motion is detected.
To configure the Wiser Motion sensor to control another Wiser product you will need to go into your Automations and create two Automations. One Automation as an ‘on’ and another as an ‘off’.
The ‘on’ Automation can be created by first selecting to add a new Automation. Once open name the Automation accordingly. Add a condition ‘when device status changes’, select the motion sensor, select motion state and occupied. Then add an action of what you want to occur when the motion sensor detects motion. As an example, if you wanted to turn on a device you would add task of ‘run the device’. This will then bring up the list of devices you have to choose from to operate and once you select a device you can then select to turn it on or off.
The ‘off’ Automation is the same as the ‘on’ Automation but select the motion sensor state of ‘unoccupied’ as the condition.