Browse all
Browse all

Standard Series Twin Switch Socket Outlet 250V, 10A, Standard Size, Indicator

Standard Series Twin Switch Socket Outlet 250V, 10A, Standard Size, Indicator | White Electric

Item Number: 25N-WE

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range of product Standard Series
Product or component type switched socket
Product brand Clipsal
Surface finish glossy

Physical

Control type ON/OFF button
Number of gangs 2 gangs
Pin number 3
Number of power socket outlets 2
Actuator
  • switch
  • rocker
Fixing mode by screws
Local signalling indicator light
Mounting position horizontal
[ue] rated operational voltage 250 V AC
[in] rated current 10 A
Depth 16 mm
Length 115 mm
Width 73 mm
Fixing center 84 mm
Standards
  • AS/NZS 3100
  • AS/NZS 3112
  • AS/NZS 3133
  • AS/NZS 3000:approval number S/1
Mercury free Yes
Rohs exemption information Yes
Environmental disclosure ENVPEP120506EN
Eu rohs directive Compliant By Exemption

Material

Material PC (polycarbonate)

Others

Legacy weee scope In
Package 1 bare product quantity 1
Average percentage of recycled plastic content 0 %
Outside of Europe
Weee label N/A
Weee applicability Finished product
Warranty duration(in months) bmecat 18
Main colour tint white electric
Unit type of package 1 PCE
Number of units in package 1 1
Package 1 height 3 cm
Package 1 width 7.3 cm
Package 1 length 11.5 cm
Package 1 weight 103.148 g
Green premium status for reporting Green Premium product
Total lifecycle carbon footprint 0.8 kg CO2 eq.
Carbon footprint of the manufacturing phase [a1 to a3] 0.5048777746430428
Carbon footprint of the manufacturing phase [a1 to a3] 0.5 kg CO2 eq.
Carbon footprint of the distribution phase [a4] 0.01907743501397431
Carbon footprint of the distribution phase [a4] 0 kg CO2 eq.
Carbon footprint of the installation phase [a5] 0.003454130359050586
Carbon footprint of the installation phase [a5] 0 kg CO2 eq.
Carbon footprint of the use phase [b2, b3, b4, b6] 0
Carbon footprint of the use phase [b2, b3, b4, b6] 0 kg CO2 eq.
Sustainable packaging No
Carbon footprint of the end-of-life phase [c1 to c4] 0.25158740897658827
Carbon footprint of the end-of-life phase [c1 to c4] 0.3 kg CO2 eq.
Pvc free Yes
Take-back No
Product contributes to saved and avoided emissions No
Removable battery N/A
Total lifecycle carbon footprint 0.778996748992656
Average percentage of recycled metal content 0 %
Packaging made with recycled cardboard Yes
Packaging without single use plastic No
Pvc free Yes
End of life manual availability N/A
Take-back No
Warranty (in months) 18

Documents & downloads

Filter items
  • All

  • Technical Data Catalogues

  • Specification Guide

  • Certificates (MSDS)

  • Declaration of Conformity

  • Declaration of Conformity (Sustainability)

Important: Some software files may need a mySchneider or Club login to download.

Frequently Asked Questions

NS1250N ML5.0E not reading frequency and showing zero Power readings.

Hide Show

Issue: Micrologic 5.0E displays NaN when reading frequency and shows zero power readings when the current is below a certain threshold.

 

Product Line: Micrologic E trip units installed with Compact NS breaker    

 

Environment: Micrologic E Trip Units

 

Resolution:

 

According to the user guide, Micrologic E trip units do not support frequency display. Therefore, frequency values are not available when using this trip unit.

For confirmation, please refer to the provided link, page 66.

https://download.schneider-electric.com/files?p_Doc_Ref=DOCA0218EN&p_enDocType=User+guide

 

Image1

A check of the register list for Compact NS breakers (refer to the attached screenshot) confirms that Compact NS units equipped with Micrologic E trip units do not support frequency display. As a result, the frequency register returns NaN.

In the register table, the A/E/P/H column applies to NT/NW and NS breakers. This table indicates that only P and H trip units support frequency measurement and display on the registers. Micrologic E trip units do not include this capability.

For further details, please refer to the linked document, page 91.

https://www.productinfo.schneider-electric.com/compactnsxmodbuscommguide/compact-nsx-modbus-comm-guide/EN/DOCA0091EN-09.pdf

 

Image 2

 

For the Issue regarding incorrect power readings:

On Micrologic 2.0E, 5.0E, and 6.0E trip units:

The power value displayed on the Micrologic E front display and transmitted via Modbus is reported as zero when the load current is below 0.07 × In, where In represents the rated input current.

The current value displayed on the Micrologic E front face and transmitted via Modbus is reported as zero when the load current is below 0.005 × In.

When the load current falls between 0.005 × In and 0.07 × In, and the voltage is non‑zero, the current and voltage values are displayed normally; however, the calculated power value remains zero.

As a result, in customer applications, power calculation effectively begins when the load current exceeds 0.07 × In (Ia).