Standard Series Twin Switch Socket Outlet 250V, 10A, Standard Size, Indicator

Standard Series Twin Switch Socket Outlet 250V, 10A, Standard Size, Indicator | Red

Item Number: 25N-RD

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range of product Standard Series
Product or component type switched socket
Product brand Clipsal
Surface finish glossy

Physical

Control type ON/OFF button
Number of gangs 2 gangs
Pin number 3
Number of power socket outlets 2
Actuator
  • switch
  • rocker
Fixing mode by screws
Local signalling indicator light
Mounting position horizontal
[ue] rated operational voltage 250 V AC
[in] rated current 10 A
Depth 16 mm
Length 115 mm
Width 73 mm
Fixing center 84 mm
Standards
  • AS/NZS 3100
  • AS/NZS 3112
  • AS/NZS 3133
  • AS/NZS 3000:approval number S/1
Mercury free Yes
Rohs exemption information Yes
Environmental disclosure ENVPEP120506EN
Reach regulation Reference contains Substances of Very High Concern above the threshold
China rohs regulation Product out of China RoHS scope
Eu rohs directive Compliant By Exemption

Material

Material PC (polycarbonate)

Others

Legacy weee scope In
Package 1 bare product quantity 1
Weee label N/A
Weee applicability Finished product
Outside of Europe
Average percentage of recycled plastic content 0 %
Warranty duration(in months) bmecat 18
Unit type of package 1 PCE
Number of units in package 1 1
Package 1 height 3 cm
Package 1 width 7.3 cm
Package 1 length 11.5 cm
Package 1 weight 103.148 g
Total lifecycle carbon footprint 0.8 kg CO2 eq.
Carbon footprint of the manufacturing phase [a1 to a3] 0.5048777746430428
Carbon footprint of the manufacturing phase [a1 to a3] 0.5 kg CO2 eq.
Carbon footprint of the distribution phase [a4] 0.01907743501397431
Carbon footprint of the distribution phase [a4] 0 kg CO2 eq.
Carbon footprint of the installation phase [a5] 0.003454130359050586
Carbon footprint of the installation phase [a5] 0 kg CO2 eq.
Carbon footprint of the use phase [b2, b3, b4, b6] 0
Carbon footprint of the use phase [b2, b3, b4, b6] 0 kg CO2 eq.
Sustainable packaging No
Carbon footprint of the end-of-life phase [c1 to c4] 0.25158740897658827
Carbon footprint of the end-of-life phase [c1 to c4] 0.3 kg CO2 eq.
Pvc free Yes
Halogen-free status Product contains halogen above thresholds
Take-back No
Product contributes to saved and avoided emissions No
Removable battery N/A
Total lifecycle carbon footprint 0.778996748992656
Average percentage of recycled metal content 0 %
Packaging made with recycled cardboard Yes
Packaging without single use plastic No
China rohs label 5
Halogen-free status Product contains halogen above thresholds
Pvc free Yes
End of life manual availability N/A
Take-back No
Warranty (in months) 18

Documents & downloads

Filter items
  • All

  • Technical Data Catalogues

  • Specification Guide

  • Certificates (MSDS)

  • Declaration of Conformity

  • Declaration of Conformity (Sustainability)

Important: Some software files may need a mySchneider or Club login to download.

Frequently Asked Questions

NS1250N ML5.0E not reading frequency and showing zero Power readings.

Hide Show

Issue: Micrologic 5.0E displays NaN when reading frequency and shows zero power readings when the current is below a certain threshold.

 

Product Line: Micrologic E trip units installed with Compact NS breaker    

 

Environment: Micrologic E Trip Units

 

Resolution:

 

According to the user guide, Micrologic E trip units do not support frequency display. Therefore, frequency values are not available when using this trip unit.

For confirmation, please refer to the provided link, page 66.

https://download.schneider-electric.com/files?p_Doc_Ref=DOCA0218EN&p_enDocType=User+guide

 

Image1

A check of the register list for Compact NS breakers (refer to the attached screenshot) confirms that Compact NS units equipped with Micrologic E trip units do not support frequency display. As a result, the frequency register returns NaN.

In the register table, the A/E/P/H column applies to NT/NW and NS breakers. This table indicates that only P and H trip units support frequency measurement and display on the registers. Micrologic E trip units do not include this capability.

For further details, please refer to the linked document, page 91.

https://www.productinfo.schneider-electric.com/compactnsxmodbuscommguide/compact-nsx-modbus-comm-guide/EN/DOCA0091EN-09.pdf

 

Image 2

 

For the Issue regarding incorrect power readings:

On Micrologic 2.0E, 5.0E, and 6.0E trip units:

The power value displayed on the Micrologic E front display and transmitted via Modbus is reported as zero when the load current is below 0.07 × In, where In represents the rated input current.

The current value displayed on the Micrologic E front face and transmitted via Modbus is reported as zero when the load current is below 0.005 × In.

When the load current falls between 0.005 × In and 0.07 × In, and the voltage is non‑zero, the current and voltage values are displayed normally; however, the calculated power value remains zero.

As a result, in customer applications, power calculation effectively begins when the load current exceeds 0.07 × In (Ia).